Enterasys Networks CM Version 1.0 manual Removing a Power Supply

Page 32

Removing a Power Supply

b.Place the lock washers over the positive and negative studs.

c.Place the nuts over the lock washers and tighten. Torque applied must be 36 in‐lb.

13.Replace the plastic shield.

14.Repeat steps 9 through 12 for each power supply.

15.Connect the DC input wiring to the DC power source.

16.Switch the branch circuit disconnect device to allow power to reach the DC power supply.

17.Set the circuit breakers on each DC power supply to On.

Note: Before you power up the Matrix X chassis, you must complete installation of fan trays and modules.

Removing a Power Supply

Warning: Disconnect all power sources before servicing.

Advertencia: Desconectar todas las fuentes de poder antes de dar mantenimiento.

Warnhinweis: Trennen sie die komplette Stromversorgung, bevor sie das Gerät warten.

To remove a DC power supply:

1.Ensure that the branch circuit disconnect device is switched to prevent power from being supplied to the DC power supply.

2.Attach the anti‐static wrist strap before handling the power supply module.

3.Switch the circuit breaker on the DC power supply to Off.

4.Remove the clear plastic shield over the terminal studs.

5.Remove the cables from the terminal studs.

6.Disconnect the earth ground stud of the power supply from the earth ground.

7.Unscrew the captive screw to release the power supply from the chassis.

8.Remove the power supply by grasping the handle and pulling it straight out of the chassis.

9.Fasten a coverplate over the empty slot.

1-14 DC Power Supply Installation

Image 32
Contents Enterasys Matrix X Router Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Supplement to Product Instructions Vcci Notice Declaration of Conformity Enterasys Networks, Inc. Firmware License Agreement Viii Page Page Contents Xii Using This Guide Using the Enterasys Matrix X Router Manual SetWho Should Use This Guide For information about Refer toConventions Used in This Guide Following conventions are used in this guideGetting Help Support@enterasys.comGetting Help Xvi About This Guide DC Power Supply Installation Earth ground stud Overview of the DC Power SupplyCircuit breaker Back View of the DC Power Supply Installation Site Requirements Power Supply Redundancy PlanningPre-Installation Tasks Verify DC Power Compliance of Matrix X ModulesDC Compliant? Worksheet DC Compliance of Modules in Existing AC SystemsModel Part No Part Number Worksheet DC Compliance of Modules for New DC Systems Model Part No Front Panel Serial Number DC Compliant?Minimum Revision of X Modules for DC Power Model Name Minimum 940 Part Number Minimum 940 RevisionUnpacking the DC Power Supply Installing the DC Power Supply Contents of X-DC CartonRemoving Power Supply Vent Plate Installing Power Supply Module Removing Blank Coverplate from Power Supply Slot Power supply slot Power supply coverplateRemoving a Power Supply Removing a Power Supply Removing a Power Supply DC Power Supply Installation Specifications Physical SpecificationsElectrical Specifications SpecificationPower Supply Redundancy Compression LugsModule Power Specifications Redundancy Configurations for DC Power Supply@ 48 VDC ModuleRegulatory Compliance Standards Regulatory ComplianceCompliance Standards