Enterasys Networks 9033989-06, 6H308-48 Connecting to a VT Series Terminal, Parameter Setting

Page 47

Connecting to COM Port for Local Management

4.Turn on the PC and configure your VT emulation package with the following parameters:

Parameter

Setting

 

 

 

Mode

7

Bit Control

 

 

Transmit

Transmit=9600

 

 

 

Bits Parity

8

Bits, No Parity

 

 

 

Stop Bit

1

Stop Bit

 

 

 

5.When these parameters are set, the Local Management password screen will display. Refer to the appropriate Enterasys Matrix DFE‐Gold Series Configuration Guide for further information.

Figure 3-9 Connecting an IBM PC or Compatible

FAST ENET

4H4285-49

1

OFFLINE/

RESET

COM

MGMT CPU POE

GROUP

SELECT

GROUP

1 1

2 2

3 3

 

 

 

 

 

Á

 

Ã

Â

À

 

 

1

UTP straight-through cable with RJ45 connectors

3

RJ45-to-DB9 PC adapter

2

RJ45 COM port

 

 

4

IBM PC or compatible device

Connecting to a VT Series Terminal

To connect a VT Series terminal to an Enterasys Networks DFE module COM port

(Figure 3‐10), use a UTP straight‐through cable with RJ45 connectors and an RJ45‐to‐DB25 female adapter, and proceed as follows:

Matrix DFE-Gold Series PoE Module 4H4285-49 Installation Guide 3-19

Image 47
Contents Enterasys Matrix Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Supplement to Product Instructions Vcci Notice Safety Information Class 1 Laser Transceivers Enterasys NETWORKS, INC. Firmware License Agreement Viii Page Page Contents Appendix C About PoE Power over Ethernet TroubleshootingAppendix a Specifications Appendix B Mode Switch Settings and Option InstallationsTables FiguresXiv Important Notice About This GuideWho Should Use This Guide For Refer to How to Use This GuideRelated Documents Following conventions are used in this guide Conventions Used in This GuideGetting Help For information about Refer to Introduction4H4285-49 Overview of DFE-Gold PoE Module CapabilitiesDFE-Gold Module DFE-Gold Module 4H4285-49 DFE-Gold Module Management Switch Configuration Using WebViewSwitch Configuration Using CLI Commands ConnectivityStandards Compatibility Lanview Diagnostic LEDsLink Aggregation Network Requirements100BASE-TX Network 10BASE-T NetworkInstallation Unpacking the DFE Module Installation Site RequirementContents of DFE Module Carton Quantity DFE Module Placement and Installation Rules Installing Optional Network Expansion Module NEMExample 1 -1, a Example 3 -1, C Preparing to Install the 4H4285-49 Installing 4H4285-49 into a Matrix E7 or N7 Chassis Preparing to Install the 4H4285-49 Card guides Installing 4H4285-49 into Matrix N3 or N5 Chassis Card guides Connecting 48 Vdc Power for PoE Operation Making the UTP Connections Connecting to the NetworkConnecting UTP Cables to 4H4285-49 Connecting a Twisted Pair Segment with RJ45 Connector RX+ TX+ RX+ Verifying PoE Port Status Connecting to an IBM PC or Compatible Device Connecting to COM Port for Local ManagementWhat Is Needed Parameter Setting Connecting to a VT Series Terminal10 Connecting a VT Series Terminal Connecting to a Modem 11 Connecting Using a Modem RJ45 DB25 Adapter Wiring and Signal AssignmentsCOM Port Adapter Wiring and Signal Diagram RJ45 VT Series Port Adapter Wiring and Signal DiagramModem Port Adapter Wiring and Signal Diagram RJ45 DB25 Completing the InstallationCompleting the Installation of a New System First-Time Log-In Using a Console Port Connection 12 Matrix Defogged Startup Screen Example N7 Chassis Enter Logging in with an Administratively-Configured User AccountCompleting the Installation About the Management Mgmt LED TroubleshootingUsing Lanview Lanview LEDs Viewing Receive/Transmit ActivityColor State Recommended Action Viewing the PoE Port StatusAlternately 67% on, 33% LED RX/TX Refer to the Matrix DFE-Gold Series Configuration Troubleshooting ChecklistMatrix DFE-Gold Series Configuration Guide for OFFLINE/RESET Switch Overview of DFE Module Shutdown ProcedureLast Resort Shutdown Procedure Using OFFLINE/RESET Switch Recommended Shutdown Procedure Using OFFLINE/RESET SwitchTable A-1 4H4285-49 Specifications Specifications4H4285-49 Specifications Processors/Memory Table A-1 4H4285-49 Specifications ItemSpecificationTable A-3 Compliance Standards Regulatory Compliance Table A-2 COM Port Pin Assignments Signal Name Input/OutputCOM Port Pinout Assignments Regulatory ComplianceRegulatory Compliance Specifications Required Tools Mode Switch Settings and Option InstallationsSetting the Mode Switches Memory Locations and Replacement Procedures Memory Locations and Replacement ProceduresGaining Access to Memory Modules Gaining Access to Memory ModulesRemoving the Safety Cover Figure B-3 Removing the Safety Cover Removing the Network Expansion Module NEM Dram Simm Replacement ProcedureFigure B-5 Removing the Existing Dram Simm Removing the Dram SimmFigure B-6 Installing the Dram Simm Installing the Dram SimmRemoving the Dimm Dimm Replacement ProcedureFigure B-8 Installing the Dimm Installing the DimmFigure B-9 Installing the Network Expansion Module Reinstalling the Optional Network Expansion ModuleReinstalling the Safety Cover Figure B-10 Installing the Safety Cover Overview About PoE Power over EthernetFront Panel 48 Vdc Interface Power InterfaceProprietary PD Detection Matrix N5 Backplane 48 Vdc InterfaceTable C-2 PoE Status LED Indications PoE Port Status PoE Port Status LEDsPoE Port Status LEDs About PoE Power over Ethernet Numerics IndexPinout assignments console port A-3
Related manuals