Troubleshooting Checklist
Table | (continued) | ||
|
|
| |
Problem | Possible Cause | Recommended Action | |
|
|
| |
Port(s) goes into | Loop condition | Verify that Spanning Tree is enabled. Refer to the | |
standby for no | detected. | Matrix | |
apparent reason. |
| the instructions to set the type of STA. | |
|
| Review the network design and delete | |
|
| unnecessary loops. | |
|
| If the problem continues, contact Enterasys | |
|
| Networks for technical support. | |
|
|
| |
User parameters | Position of Mode switch | Reenter the lost parameters as necessary. Refer | |
(IP address, device | (7), Persistent Data | to the Matrix | |
and module name, | Reset, was changed | Guide for the instructions to configure the device. | |
and so forth) were | sometime before either | If the problem continues, contact Enterasys | |
lost when the | cycling power or | ||
Networks for technical support. | |||
module power was | pressing the OFFLINE/ | ||
| |||
cycled, the front | RESET switch, causing |
| |
panel OFFLINE/ | the |
| |
RESET switch was | parameters to reset to |
| |
pressed. | factory default settings. |
|
Clear Persistent Data was set through Local Management.
The module was moved either from