Enterasys Networks 9033989-06, 6H308-48, 4H4285-49 manual Rx/Tx

Page 62

Using LANVIEW

Table 4-1 LANVIEW LEDs (continued)

LED

Color

State

Recommended Action

 

 

RX/TX LED Indications in PoE Port Status Mode

 

 

 

 

 

RX/TX

Green/

There is a connection to a

None.

 

Off

PD. There is 48 Vdc at the

 

 

 

RJ45 connector.

 

Off/Red Port is off due to overload. The attached device exceeded maximum load according to 802.3af standard PoE device power classification.

1.Check the attached PD to see if it is defective and drawing too much power for its Power Classification.

2.Check Ethernet cable from the PD for short circuits.

3.Contact Enterasys Networks for technical support.

Red/Off Port is off due to PoE power None management. Port may be

turned off due to priority or other administration configuration.

Off/Off

Port is off for other reason.

1.There is no connection to a PD.

2.If the DFE module is in an N5 chassis, ensure that the N5 is turned on.

3.If connected to an N-POE Power System, ensure that the power system is turned on.

4.If the power is being received from an N-POE Power System, check the 48 Vdc power cable connection.

5.Swap 48 Vdc power cable with a known good one.

6.If you still have a problem, contact Enterasys Networks for technical support.

4-6 Troubleshooting

Image 62
Contents Enterasys Matrix Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Supplement to Product Instructions Vcci Notice Safety Information Class 1 Laser Transceivers Enterasys NETWORKS, INC. Firmware License Agreement Viii Page Page Contents Appendix B Mode Switch Settings and Option Installations TroubleshootingAppendix a Specifications Appendix C About PoE Power over EthernetFigures TablesXiv Important Notice About This GuideWho Should Use This Guide For Refer to How to Use This GuideRelated Documents Conventions Used in This Guide Following conventions are used in this guideGetting Help Introduction For information about Refer to4H4285-49 Overview of DFE-Gold PoE Module CapabilitiesDFE-Gold Module DFE-Gold Module 4H4285-49 DFE-Gold Module Connectivity Switch Configuration Using WebViewSwitch Configuration Using CLI Commands ManagementLanview Diagnostic LEDs Standards CompatibilityNetwork Requirements Link Aggregation10BASE-T Network 100BASE-TX NetworkInstallation Unpacking the DFE Module Installation Site RequirementContents of DFE Module Carton Quantity Installing Optional Network Expansion Module NEM DFE Module Placement and Installation RulesExample 1 -1, a Example 3 -1, C Preparing to Install the 4H4285-49 Installing 4H4285-49 into a Matrix E7 or N7 Chassis Preparing to Install the 4H4285-49 Card guides Installing 4H4285-49 into Matrix N3 or N5 Chassis Card guides Connecting 48 Vdc Power for PoE Operation Making the UTP Connections Connecting to the NetworkConnecting UTP Cables to 4H4285-49 Connecting a Twisted Pair Segment with RJ45 Connector RX+ TX+ RX+ Verifying PoE Port Status Connecting to an IBM PC or Compatible Device Connecting to COM Port for Local ManagementWhat Is Needed Connecting to a VT Series Terminal Parameter Setting10 Connecting a VT Series Terminal Connecting to a Modem 11 Connecting Using a Modem VT Series Port Adapter Wiring and Signal Diagram Adapter Wiring and Signal AssignmentsCOM Port Adapter Wiring and Signal Diagram RJ45 RJ45 DB25Modem Port Adapter Wiring and Signal Diagram RJ45 DB25 Completing the InstallationCompleting the Installation of a New System First-Time Log-In Using a Console Port Connection 12 Matrix Defogged Startup Screen Example N7 Chassis Logging in with an Administratively-Configured User Account EnterCompleting the Installation About the Management Mgmt LED TroubleshootingUsing Lanview Viewing Receive/Transmit Activity Lanview LEDsViewing the PoE Port Status Color State Recommended ActionAlternately 67% on, 33% LED RX/TX Troubleshooting Checklist Refer to the Matrix DFE-Gold Series ConfigurationMatrix DFE-Gold Series Configuration Guide for Overview of DFE Module Shutdown Procedure OFFLINE/RESET SwitchRecommended Shutdown Procedure Using OFFLINE/RESET Switch Last Resort Shutdown Procedure Using OFFLINE/RESET SwitchTable A-1 4H4285-49 Specifications Specifications4H4285-49 Specifications Table A-1 4H4285-49 Specifications ItemSpecification Processors/MemoryRegulatory Compliance Table A-2 COM Port Pin Assignments Signal Name Input/OutputCOM Port Pinout Assignments Table A-3 Compliance Standards Regulatory ComplianceRegulatory Compliance Specifications Mode Switch Settings and Option Installations Required ToolsSetting the Mode Switches Memory Locations and Replacement Procedures Memory Locations and Replacement ProceduresGaining Access to Memory Modules Gaining Access to Memory ModulesRemoving the Safety Cover Figure B-3 Removing the Safety Cover Dram Simm Replacement Procedure Removing the Network Expansion Module NEMRemoving the Dram Simm Figure B-5 Removing the Existing Dram SimmInstalling the Dram Simm Figure B-6 Installing the Dram SimmDimm Replacement Procedure Removing the DimmInstalling the Dimm Figure B-8 Installing the DimmReinstalling the Optional Network Expansion Module Figure B-9 Installing the Network Expansion ModuleReinstalling the Safety Cover Figure B-10 Installing the Safety Cover About PoE Power over Ethernet OverviewMatrix N5 Backplane 48 Vdc Interface Power InterfaceProprietary PD Detection Front Panel 48 Vdc InterfacePoE Port Status LEDs Table C-2 PoE Status LED Indications PoE Port StatusPoE Port Status LEDs About PoE Power over Ethernet Index NumericsPinout assignments console port A-3
Related manuals
Manual 56 pages 18.08 Kb