The following hardware platforms are supported by this release of this guide:

The PowerConnect B-FCX624s stackable switch has twenty 10/100/1000 Mbps RJ45 ports plus four Combo ports, which include four 10/100/1000 Mbps RJ45 ports and four 100/1000 Mbps SFP ports. The switch has two management interfaces, a DB9 serial port (Console) on the front panel and an RJ45 port (Out-of-band Management Interface) on the rear panel. Two rear-panel power supply receptacles allow for up to two power supply units. Two dedicated 16 GbE CX4 ports on the rear panel allow stacking for up to eight units. The front panel also has a module slot for an optional two-port 10 Gbps XFP module.

The PowerConnect B-FCX648s stackable switch has forty four 10/100/1000 Mbps RJ45 ports plus four Combo ports, which include four 10/100/1000 Mbps RJ45 ports and four 100/1000 Mbps SFP ports. The switch has two management interfaces, a DB9 serial port (Console) on the front panel and an RJ45 port (Out-of-band Management Interface) on the rear panel. Two rear-panel power supply receptacles allow for up to two power supply units. Two dedicated 16 Gbps Ethernet CX4 ports on the rear panel allow stacking for up to eight units. The front panel also has a module slot for an optional two-port 10 Gbps Ethernet XFP module.

The PowerConnect B-FCX624-E switch has twenty four 10/100/1000 Mbps RJ45 ports plus four Combo 1 Gbps ports. The device has two management interfaces on the front panel, a DB9 serial port (Console) and an RJ45 port (Out-of-band Management Interface). The front panel has a slot for an optional four-port 1GbE SFP module (works as Combo port) or four-port 10 Gbps SFP+ module. On the rear panel a removable fan tray provides a cooling airflow from the front to the back (FtB) of the device. Two rear-panel power supply receptacles accommodate up to two power supply units that also support a front-to-back cooling airflow.

The PowerConnect B-FCX624-I switch has twenty four 10/100/1000 Mbps RJ45 ports plus four Combo 1 Gbps ports. The device has two management interfaces on the front panel, a serial port (Console) and an RJ45 port (Out-of-band Management Interface). The front panel has a slot for an optional four-port 1GbE SFP module (works as Combo port) or four-port 10 Gbps SFP+ module. On the rear panel a removable fan tray provides a cooling airflow from the back to the front (BtF) of the device. Two rear-panel power supply receptacles accommodate up to two power supply units that also support a back-to-front cooling airflow.

The PowerConnect B-FCX648-E switch has forty four 10/100/1000 Mbps RJ45 ports plus four Combo 1 Gbps ports. The device has two management interfaces on the front panel, a serial port (Console) and an RJ45 port (Out-of-band Management Interface). The front panel has a slot for an optional four-port 1GbE SFP module (works as Combo port) or four-port 10 Gbps SFP+ module. On the rear panel a removable fan tray provides a cooling airflow from the front to the back (FtB) of the device. Two rear-panel power supply receptacles accommodate up to two power supply units that also support a front-to-back cooling airflow.

PowerConnect B-FCX Switch Hardware Installation Guide

1

53-1002267-01

 

Image 11
Contents PowerConnect B-FCX Switch Page Contents Managing the PowerConnect B-FCX Hardware Checking Network Devices and Testing ConnectivityChapter Troubleshooting PowerConnect B-FCX Switch Hardware Installation Guide Text formatting AudienceSupported hardware and software Document conventions Related publications Command syntax conventions Command Parameters Contacting Dell Getting technical help or reporting errorsPowerConnect B-FCX Switch Hardware Installation Guide Product Overview Hardware featuresPowerConnect B-FCX624s front panel Device Label on required power supply Control featuresHardware features Out-of-band RJ45 management interface Hardware features Out-of-band RJ45 management InterfacePowerConnect B-FCX 10/100/1000 BASE-T ports Serial management interface DB9 Console portDevice Slot Slot designationsInterface Show Media Description SFP interfacesOptional two-port 10 Gbps XFP uplink module Condition Status Optional Four-port 1 Gbps SFP and 10 Gbps SFP+ modulesOptional 10Gbps XFP module is not hot-swappable Four-port 1 Gbps SFP module status LEDsFour-port 10 Gbps SFP+ module status LEDs Cable specifications for CX4 stacking ports16/10 Gbps Ethernet CX4 stacking ports Port status LEDs Power status LEDs Hardware features System status LEDsState Switch StatusSFP+ Hardware features Port status LEDsSwitch Status Redundancy Power suppliesPower supply unit operation General requirements Package contentsUnpacking the device Task Where to Find More Information Number Installation tasksInstallation precautions Follow all precautions when installing a Dell deviceInstallation precautions General precautionsLifting precautions Power precautionsCabling infrastructure Preparing the installation siteInstallation location Preparing the installation siteDesktop installation Installing the deviceRack mount installation PowerConnect B-FCX624s and PowerConnect B-FCX648s devices Connecting devices in a stackPowerConnect B-FCX Switch Hardware Installation Guide PowerConnect B-FCX624 and PowerConnect B-FCX648 devices Powering on the system Attaching a PC or terminal As indicated in , some of the wires should not be connected Installing and replacing a power supply unitWiring map for serial cable Serial cable wiringInstalling and replacing a power supply unit PowerConnect B-FCX Switch Hardware Installation Guide Page PowerConnect B-FCX Switch Hardware Installation Guide Page PowerConnect B-FCX Switch Hardware Installation Guide Assigning permanent passwords Checking Network Devices and Testing ConnectivityEnter the following command to set the super user password Setting passwordsRecovering from a lost password Assigning permanent passwordsDevices running Layer 2 software Configuring IP addressesSyntax enable password Devices running Layer 3 software Assigning an IP address to an Ethernet port Configuring IP addressesSyntax router-interface ve num Syntax interface ve num Deleting an IP addressSyntax interface loopback num Assigning an IP address to a virtual routing interfaceConnecting to Ethernet or fast Ethernet hubs Connecting network devicesConnectors Cable specificationsFiber Optic transceivers Connecting to workstations, servers, or routersConnecting a network device to a fiber port Automatic MDI or Mdix detectionGigabit Optic Distance Supported for stacking Installing a transceiverAll fiber optic interfaces use Class 1 lasers Cabling a fiber optic transceiver Pinging an IP address Testing connectivityCleaning the fiber optic connectors Testing connectivityMeaning or Action Testing connectivity Network connection-related LED statesDesired Meaning Tracing a route Troubleshooting network connectionsViewing the results of the cable analysis Using Virtual Cable Testing to diagnose a cableConfiguration notes Command syntaxThis Line Displays Digital optical monitoringSyntax show cable-diag tdr port-num Defines the fields shown in this output Cable statisticsTroubleshooting network connections Displaying the temperature Managing temperature settingsUsing the temperature sensor Syntax temperature warning stack-unit value Displaying Syslog messages for temperatureChanging temperature warning and shutdown levels Managing temperature settingsSyntax fan-threshold speed-3 mp lowest value highest value Changing the shutdown temperatureCommand Syntax chassis poll-time stack-idvalue Displaying PowerConnect B-FCX CPU usageChanging the temperature polling interval Removing MAC address entriesRemoving a copper or fiber optic module Hardware maintenance scheduleHardware maintenance schedule Replacing a copper or fiber optic moduleReplacing a copper or fiber optic module Cleaning the fiber optic connectorsCabling a fiber optic module Replacing a copper or fiber optic module Operating Environment Hardware specificationsPhysical dimensions and weight Environmental considerationsStorage environment Hardware specificationsStorage Temperature Storage Humidity Storage Altitude Cooling system and fansAir Inflow Air outlet Mgmt Serial Console port pinouts Pinouts and signallingMicrons MHz*km or Cable Type Connector TypeRange meters Hardware specifications Cable length summary Power cordsAC power supply specifications Hardware specifications Troubleshooting chart Diagnosing switch indicatorsPower and cooling problems InstallationDiagnosing switch indicators In-band accessJapan Vcci USA FCC CFR 47 Part 15 WarningIndustry Canada statement Europe and Australia Cispr 22 Class a WarningClass a statement Japan power cordKorea RussiaCertifications Regulatory complianceRegulatory compliance Regulatory compliance Vorsicht Devices near the input power connectors Never leave tools inside the chassis Gefahr Device PowerConnect B-FCX Switch Hardware Installation Guide