Dell B-FCX manual Testing connectivity Network connection-related LED states, Desired Meaning

Page 54

3 Testing connectivity

TABLE 19

Network connection-related LED states

 

 

 

 

 

 

LED

Desired

Meaning

Abnormal State

Meaning or Action

 

State

 

 

 

 

 

 

 

 

Ethernet

On or

A link is established with

Off

A link is not established with the remote port. You can do the

(1-24/48)

Blinking

the remote port and user

 

following:

Link or

(Green or

packets are being

 

Verify that the connection to the other network device has

Activity or

Amber)

transmitted or received.

 

been properly made. Also, make certain that the other

Speed

 

 

 

network device is powered on and operating correctly.

 

 

 

 

Verify that the port has not been disabled through a

 

 

 

 

configuration change. You can use the CLI. If you have

 

 

 

 

configured an IP address on the device, you also can use

 

 

 

 

the Web management interface or Brocade Network

 

 

 

 

Advisor.

 

 

 

 

For the combination ports (ports 1~4), check that the

 

 

 

 

shared SFP port (1F~4F) is not being used.

 

 

 

 

If the other actions don’t resolve the problem, try using a

 

 

 

 

different port or a different cable.

 

 

 

 

 

SFP

On Green

A link is established with

Off

A link is not established with the remote port. You can do the

(1F~4F)

 

the remote port.

 

following:

Link or

 

 

 

Verify that the connection to the other network device has

Activity

 

 

 

been properly made. Also, make certain that the other

 

 

 

 

network device is powered on and operating correctly.

 

 

 

 

Verify that the transmit port on the Dell device is

 

 

 

 

connected to the receive port on the other network device,

 

 

 

 

and that the receive port on the Dell device is connected

 

 

 

 

to the transmit port on the other network device. If you are

 

 

 

 

not certain, remove the two cable connectors from the

 

 

 

 

port connector and reinsert them in the port connector,

 

 

 

 

reversing their order.

 

 

 

 

Dust may have accumulated in the cable connector or port

 

 

 

 

connector. For information about cleaning the connectors,

 

 

 

 

refer to “Cleaning the fiber optic connectors” on page 43.

 

 

 

 

Verify that the port has not been disabled through a

 

 

 

 

configuration change.

 

 

 

 

Check that the configuration has not forced the use of the

 

 

 

 

RJ45 port shared with the SFP port.

 

 

 

 

If the other actions don’t resolve the problem, try using a

 

 

 

 

different port or a different cable.

 

 

 

 

 

SFP

On (Green

A link is established with

Off

A link is not established with the remote port. You can do the

(1F~4F)

or Amber)

the remote port.

 

following:

Speed

 

 

 

Check the Link LED to make sure the link is still

established with the remote port. If not, take the actions described in the Meaning or Action column for the Link LED.

44

PowerConnect B-FCX Switch Hardware Installation Guide

 

53-1002267-01

Image 54
Contents PowerConnect B-FCX Switch Page Contents Checking Network Devices and Testing Connectivity Managing the PowerConnect B-FCX HardwareChapter Troubleshooting PowerConnect B-FCX Switch Hardware Installation Guide Document conventions AudienceSupported hardware and software Text formattingCommand syntax conventions Command ParametersRelated publications Getting technical help or reporting errors Contacting DellPowerConnect B-FCX Switch Hardware Installation Guide Hardware features Product OverviewPowerConnect B-FCX624s front panel Control features Hardware featuresDevice Label on required power supply Serial management interface DB9 Console port Hardware features Out-of-band RJ45 management InterfacePowerConnect B-FCX 10/100/1000 BASE-T ports Out-of-band RJ45 management interfaceSlot designations Device SlotSFP interfaces Optional two-port 10 Gbps XFP uplink moduleInterface Show Media Description Four-port 1 Gbps SFP module status LEDs Optional Four-port 1 Gbps SFP and 10 Gbps SFP+ modulesOptional 10Gbps XFP module is not hot-swappable Condition StatusCable specifications for CX4 stacking ports 16/10 Gbps Ethernet CX4 stacking portsFour-port 10 Gbps SFP+ module status LEDs Port status LEDs Hardware features System status LEDs Power status LEDsSwitch Status StateHardware features Port status LEDs SFP+Power supplies Switch Status RedundancyPower supply unit operation Package contents Unpacking the deviceGeneral requirements Follow all precautions when installing a Dell device Installation tasksInstallation precautions Task Where to Find More Information NumberPower precautions General precautionsLifting precautions Installation precautionsPreparing the installation site Preparing the installation siteInstallation location Cabling infrastructureInstalling the device Desktop installationRack mount installation Connecting devices in a stack PowerConnect B-FCX624s and PowerConnect B-FCX648s devicesPowerConnect B-FCX Switch Hardware Installation Guide PowerConnect B-FCX624 and PowerConnect B-FCX648 devices Powering on the system Attaching a PC or terminal Serial cable wiring Installing and replacing a power supply unitWiring map for serial cable As indicated in , some of the wires should not be connectedInstalling and replacing a power supply unit PowerConnect B-FCX Switch Hardware Installation Guide Page PowerConnect B-FCX Switch Hardware Installation Guide Page PowerConnect B-FCX Switch Hardware Installation Guide Checking Network Devices and Testing Connectivity Assigning permanent passwordsAssigning permanent passwords Setting passwordsRecovering from a lost password Enter the following command to set the super user passwordConfiguring IP addresses Syntax enable passwordDevices running Layer 2 software Devices running Layer 3 software Configuring IP addresses Assigning an IP address to an Ethernet portAssigning an IP address to a virtual routing interface Deleting an IP addressSyntax interface loopback num Syntax router-interface ve num Syntax interface ve numCable specifications Connecting network devicesConnectors Connecting to Ethernet or fast Ethernet hubsAutomatic MDI or Mdix detection Connecting to workstations, servers, or routersConnecting a network device to a fiber port Fiber Optic transceiversInstalling a transceiver All fiber optic interfaces use Class 1 lasersGigabit Optic Distance Supported for stacking Cabling a fiber optic transceiver Testing connectivity Testing connectivityCleaning the fiber optic connectors Pinging an IP addressTesting connectivity Network connection-related LED states Desired MeaningMeaning or Action Troubleshooting network connections Tracing a routeCommand syntax Using Virtual Cable Testing to diagnose a cableConfiguration notes Viewing the results of the cable analysisDefines the fields shown in this output Cable statistics Digital optical monitoringSyntax show cable-diag tdr port-num This Line DisplaysTroubleshooting network connections Managing temperature settings Using the temperature sensorDisplaying the temperature Managing temperature settings Displaying Syslog messages for temperatureChanging temperature warning and shutdown levels Syntax temperature warning stack-unit valueChanging the shutdown temperature Syntax fan-threshold speed-3 mp lowest value highest valueCommand Removing MAC address entries Displaying PowerConnect B-FCX CPU usageChanging the temperature polling interval Syntax chassis poll-time stack-idvalueReplacing a copper or fiber optic module Hardware maintenance scheduleHardware maintenance schedule Removing a copper or fiber optic moduleCleaning the fiber optic connectors Cabling a fiber optic moduleReplacing a copper or fiber optic module Replacing a copper or fiber optic module Environmental considerations Hardware specificationsPhysical dimensions and weight Operating EnvironmentCooling system and fans Hardware specificationsStorage Temperature Storage Humidity Storage Altitude Storage environmentAir Inflow Air outlet Mgmt Pinouts and signalling Serial Console port pinoutsCable Type Connector Type Range metersMicrons MHz*km or Power cords AC power supply specificationsHardware specifications Cable length summary Hardware specifications Installation Diagnosing switch indicatorsPower and cooling problems Troubleshooting chartIn-band access Diagnosing switch indicatorsEurope and Australia Cispr 22 Class a Warning USA FCC CFR 47 Part 15 WarningIndustry Canada statement Japan VcciRussia Japan power cordKorea Class a statementRegulatory compliance Regulatory complianceCertifications Regulatory compliance Vorsicht Devices near the input power connectors Never leave tools inside the chassis Gefahr Device PowerConnect B-FCX Switch Hardware Installation Guide