Dell B-FCX manual Device

Page 85

 

Danger notices

B

 

 

DANGER

Disconnect the power cord from all power sources to completely remove power from the

 

device.

 

 

 

 

GEFAHR

Ziehen Sie das Stromkabel aus allen Stromquellen, um sicherzustellen, dass dem

 

 

Gerät kein Strom zugeführt wird.

 

 

 

DANGER

Débranchez le cordon d'alimentation de toutes les sources d'alimentation pour couper

 

complètement l'alimentation du dispositif.

 

 

 

PELIGRO

Para desconectar completamente la corriente del instrumento, desconecte el cordón

 

de corriente de todas las fuentes de corriente.

 

 

 

 

 

DANGER

If the installation requires a different power cord than the one supplied with the device,

 

make sure you use a power cord displaying the mark of the safety agency that defines

 

the regulations for power cords in your country. The mark is your assurance that the

 

power cord can be used safely with the device.

 

 

 

 

GEFAHR

Falls für die Installation ein anderes Stromkabel erforderlich ist (wenn das mit dem

 

 

Gerät gelieferte Kabel nicht passt), müssen Sie sicherstellen, dass Sie ein Stromkabel

 

mit dem Siegel einer Sicherheitsbehörde verwenden, die für die Zertifizierung von

 

 

Stromkabeln in Ihrem Land zuständig ist. Das Siegel ist Ihre Garantie, dass das

 

 

Stromkabel sicher mit Ihrem Gerät verwendet werden kann.

 

 

 

 

DANGER

Si l'installation nécessite un cordon d'alimentation autre que celui fourni avec le

 

 

dispositif, assurez-vous d'utiliser un cordon d'alimentation portant la marque de

 

 

l'organisation responsable de la sécurité qui définit les normes et régulations pour les

 

cordons d'alimentation dans votre pays. Cette marque vous assure que vous pouvez

 

utiliser le cordon d'alimentation avec le dispositif en toute sécurité.

 

 

 

PELIGRO

Si la instalación requiere un cordón de corriente distinto al que se ha suministrado con

 

el instrumento, verifique que usa un cordón de corriente que venga con la marca de la

 

agencia de seguridad que defina las regulaciones para cordones de corriente en su

 

país. Esta marca será su garantía de que el cordón de corriente puede ser utilizado con

 

seguridad con el instrumento.

 

 

 

 

 

DANGER

For safety reasons, the ESD wrist strap should contain a series 1 meg ohm resistor.

 

 

 

GEFAHR

Aus Sicherheitsgründen sollte ein EGB-Armband zum Schutz von elektronischen

 

 

gefährdeten Bauelementen mit einem 1 Megaohm-Reihenwiderstand ausgestattet

 

 

sein.

 

 

 

DANGER

Pour des raisons de sécurité, la dragonne ESD doit contenir une résistance de

 

série 1 méga ohm.

 

 

 

PELIGRO

Por razones de seguridad, la correa de muñeca ESD deberá contener un resistor en

 

serie de 1 mega ohmio.

 

 

 

 

PowerConnect B-FCX Switch Hardware Installation Guide

75

53-1002267-01

 

Image 85
Contents PowerConnect B-FCX Switch Page Contents Managing the PowerConnect B-FCX Hardware Checking Network Devices and Testing ConnectivityChapter Troubleshooting PowerConnect B-FCX Switch Hardware Installation Guide Supported hardware and software AudienceDocument conventions Text formattingCommand Parameters Command syntax conventionsRelated publications Contacting Dell Getting technical help or reporting errorsPowerConnect B-FCX Switch Hardware Installation Guide Product Overview Hardware featuresPowerConnect B-FCX624s front panel Hardware features Control featuresDevice Label on required power supply PowerConnect B-FCX 10/100/1000 BASE-T ports Hardware features Out-of-band RJ45 management InterfaceSerial management interface DB9 Console port Out-of-band RJ45 management interfaceDevice Slot Slot designationsOptional two-port 10 Gbps XFP uplink module SFP interfacesInterface Show Media Description Optional 10Gbps XFP module is not hot-swappable Optional Four-port 1 Gbps SFP and 10 Gbps SFP+ modulesFour-port 1 Gbps SFP module status LEDs Condition Status16/10 Gbps Ethernet CX4 stacking ports Cable specifications for CX4 stacking portsFour-port 10 Gbps SFP+ module status LEDs Port status LEDs Power status LEDs Hardware features System status LEDsState Switch StatusSFP+ Hardware features Port status LEDsSwitch Status Redundancy Power suppliesPower supply unit operation Unpacking the device Package contentsGeneral requirements Installation precautions Installation tasksFollow all precautions when installing a Dell device Task Where to Find More Information NumberLifting precautions General precautionsPower precautions Installation precautionsInstallation location Preparing the installation sitePreparing the installation site Cabling infrastructureDesktop installation Installing the deviceRack mount installation PowerConnect B-FCX624s and PowerConnect B-FCX648s devices Connecting devices in a stackPowerConnect B-FCX Switch Hardware Installation Guide PowerConnect B-FCX624 and PowerConnect B-FCX648 devices Powering on the system Attaching a PC or terminal Wiring map for serial cable Installing and replacing a power supply unitSerial cable wiring As indicated in , some of the wires should not be connectedInstalling and replacing a power supply unit PowerConnect B-FCX Switch Hardware Installation Guide Page PowerConnect B-FCX Switch Hardware Installation Guide Page PowerConnect B-FCX Switch Hardware Installation Guide Assigning permanent passwords Checking Network Devices and Testing ConnectivityRecovering from a lost password Setting passwordsAssigning permanent passwords Enter the following command to set the super user passwordSyntax enable password Configuring IP addressesDevices running Layer 2 software Devices running Layer 3 software Assigning an IP address to an Ethernet port Configuring IP addressesSyntax interface loopback num Deleting an IP addressAssigning an IP address to a virtual routing interface Syntax router-interface ve num Syntax interface ve numConnectors Connecting network devicesCable specifications Connecting to Ethernet or fast Ethernet hubsConnecting a network device to a fiber port Connecting to workstations, servers, or routersAutomatic MDI or Mdix detection Fiber Optic transceiversAll fiber optic interfaces use Class 1 lasers Installing a transceiverGigabit Optic Distance Supported for stacking Cabling a fiber optic transceiver Cleaning the fiber optic connectors Testing connectivityTesting connectivity Pinging an IP addressDesired Meaning Testing connectivity Network connection-related LED statesMeaning or Action Tracing a route Troubleshooting network connectionsConfiguration notes Using Virtual Cable Testing to diagnose a cableCommand syntax Viewing the results of the cable analysisSyntax show cable-diag tdr port-num Digital optical monitoringDefines the fields shown in this output Cable statistics This Line DisplaysTroubleshooting network connections Using the temperature sensor Managing temperature settingsDisplaying the temperature Changing temperature warning and shutdown levels Displaying Syslog messages for temperatureManaging temperature settings Syntax temperature warning stack-unit valueSyntax fan-threshold speed-3 mp lowest value highest value Changing the shutdown temperatureCommand Changing the temperature polling interval Displaying PowerConnect B-FCX CPU usageRemoving MAC address entries Syntax chassis poll-time stack-idvalueHardware maintenance schedule Hardware maintenance scheduleReplacing a copper or fiber optic module Removing a copper or fiber optic moduleCabling a fiber optic module Cleaning the fiber optic connectorsReplacing a copper or fiber optic module Replacing a copper or fiber optic module Physical dimensions and weight Hardware specificationsEnvironmental considerations Operating EnvironmentStorage Temperature Storage Humidity Storage Altitude Hardware specificationsCooling system and fans Storage environmentAir Inflow Air outlet Mgmt Serial Console port pinouts Pinouts and signallingRange meters Cable Type Connector TypeMicrons MHz*km or AC power supply specifications Power cordsHardware specifications Cable length summary Hardware specifications Power and cooling problems Diagnosing switch indicatorsInstallation Troubleshooting chartDiagnosing switch indicators In-band accessIndustry Canada statement USA FCC CFR 47 Part 15 WarningEurope and Australia Cispr 22 Class a Warning Japan VcciKorea Japan power cordRussia Class a statementRegulatory compliance Regulatory complianceCertifications Regulatory compliance Vorsicht Devices near the input power connectors Never leave tools inside the chassis Gefahr Device PowerConnect B-FCX Switch Hardware Installation Guide