Dell B-FCX manual Power cords, AC power supply specifications

Page 73

 

 

 

 

 

Hardware specifications

5

TABLE 24

Cable length summary (Continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable Type

Connector Type

Core Diameter

Modal Bandwidth

Range (meters)

 

 

 

 

 

(microns)

(MHz*km) or

 

 

 

 

 

 

 

Wavelength (nm)

 

 

 

 

 

 

 

 

 

 

1000Base-T

 

Copper

RJ-45 jack for standard

n/a

n/a

up to 100 meters

 

 

 

 

unshielded twisted pair (UTP

 

 

 

 

 

 

 

or Category 5)

 

 

 

 

 

 

 

 

 

 

 

100Base-BX-U

SMF

LC connector for SFP module

9

1310/1490

10000 (10 km)

 

100Base-BX-D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Base-FX

 

MMF

LC connector for SFP module

62.5

500

up to 2000 (2 km)

 

 

 

 

 

 

 

 

100Base-FX-IR

MMF

SC

62.5

125

2 km (1.24 miles)

 

 

 

 

 

 

 

 

100Base-FX-LR

SMF

SC

9

125

20 km

 

 

 

 

 

 

 

(12.43 miles)

 

 

 

 

 

 

 

 

 

10GBase-CX4

 

Infiniband 4x

XAUI connector

n/a

n/a

up to 15

 

 

 

copper

 

 

 

 

 

 

 

 

 

 

 

 

 

10G SFP+

 

TWNX

SFP

n/a

n/a

up to 15

 

 

 

 

 

 

 

 

 

Power cords

All devices ship with US-compatible power cords unless otherwise specified at the time of order. United Kingdom- and European-compatible power cords are also available.

AC power supply specifications

All devices ship with one removable AC power supply unit with a standard IEC type (IEC320) input connector, operating 100 VAC to 240 VAC input, universal or wide input. Table 25 lists the AC power supply specifications for these devices.

NOTE

For Class 1, 2, or 3 power usage, these devices can support up to 48 ports.

TABLE 25

AC power supply specifications

 

 

 

 

 

 

 

 

 

 

 

 

Input voltage range

Input current

Inrush current

Power draw

Max output power

 

 

 

(PSU x 1)

 

 

(PSU x1)

 

 

 

 

 

 

PowerConnect

100 - 240 VAC

1.2 - 2.8 Amps

< 75 Amps peak

93.67 W

210 W

B-FCX624s

 

 

 

maximum

 

 

 

 

 

 

 

 

PowerConnect

100 - 240 VAC

1.2 - 2.8 Amps

< 75 Amps peak

122.62 W

210 W

B-FCX648s

 

 

 

maximum

 

 

 

 

 

 

 

 

PowerConnect

100 - 240 VAC

1.2 - 2.8 Amps

< 75 Amps peak

57.36 W

210 W

B-FCX624-E

 

 

 

maximum

 

 

 

 

 

 

 

 

PowerConnect

100 - 240 VAC

1.2 - 2.8 Amps

< 75 Amps peak

57.36 W

210 W

B-FCX624-I

 

 

 

maximum

 

 

 

 

 

 

 

 

PowerConnect

100 - 240 VAC

1.2 - 2.8 Amps

< 75 Amps peak

57.36 W

210 W

B-FCX648-E

 

 

 

maximum

 

 

 

 

 

 

 

 

PowerConnect

100 - 240 VAC

1.2 - 2.8 Amps

< 75 Amps peak

57.36 W

210 W

B-FCX648-I

 

 

 

maximum

 

 

 

 

 

 

 

 

 

PowerConnect B-FCX Switch Hardware Installation Guide

63

53-1002267-01

 

Image 73
Contents PowerConnect B-FCX Switch Page Contents Managing the PowerConnect B-FCX Hardware Checking Network Devices and Testing ConnectivityChapter Troubleshooting PowerConnect B-FCX Switch Hardware Installation Guide Supported hardware and software AudienceDocument conventions Text formattingCommand Parameters Command syntax conventionsRelated publications Contacting Dell Getting technical help or reporting errorsPowerConnect B-FCX Switch Hardware Installation Guide Product Overview Hardware featuresPowerConnect B-FCX624s front panel Hardware features Control featuresDevice Label on required power supply PowerConnect B-FCX 10/100/1000 BASE-T ports Hardware features Out-of-band RJ45 management InterfaceSerial management interface DB9 Console port Out-of-band RJ45 management interfaceDevice Slot Slot designationsOptional two-port 10 Gbps XFP uplink module SFP interfacesInterface Show Media Description Optional 10Gbps XFP module is not hot-swappable Optional Four-port 1 Gbps SFP and 10 Gbps SFP+ modulesFour-port 1 Gbps SFP module status LEDs Condition Status16/10 Gbps Ethernet CX4 stacking ports Cable specifications for CX4 stacking portsFour-port 10 Gbps SFP+ module status LEDs Port status LEDs Power status LEDs Hardware features System status LEDsState Switch StatusSFP+ Hardware features Port status LEDsSwitch Status Redundancy Power suppliesPower supply unit operation Unpacking the device Package contentsGeneral requirements Installation precautions Installation tasksFollow all precautions when installing a Dell device Task Where to Find More Information NumberLifting precautions General precautionsPower precautions Installation precautionsInstallation location Preparing the installation sitePreparing the installation site Cabling infrastructureDesktop installation Installing the deviceRack mount installation PowerConnect B-FCX624s and PowerConnect B-FCX648s devices Connecting devices in a stackPowerConnect B-FCX Switch Hardware Installation Guide PowerConnect B-FCX624 and PowerConnect B-FCX648 devices Powering on the system Attaching a PC or terminal Wiring map for serial cable Installing and replacing a power supply unitSerial cable wiring As indicated in , some of the wires should not be connectedInstalling and replacing a power supply unit PowerConnect B-FCX Switch Hardware Installation Guide Page PowerConnect B-FCX Switch Hardware Installation Guide Page PowerConnect B-FCX Switch Hardware Installation Guide Assigning permanent passwords Checking Network Devices and Testing ConnectivityRecovering from a lost password Setting passwordsAssigning permanent passwords Enter the following command to set the super user passwordSyntax enable password Configuring IP addressesDevices running Layer 2 software Devices running Layer 3 software Assigning an IP address to an Ethernet port Configuring IP addressesSyntax interface loopback num Deleting an IP addressAssigning an IP address to a virtual routing interface Syntax router-interface ve num Syntax interface ve numConnectors Connecting network devicesCable specifications Connecting to Ethernet or fast Ethernet hubsConnecting a network device to a fiber port Connecting to workstations, servers, or routersAutomatic MDI or Mdix detection Fiber Optic transceiversAll fiber optic interfaces use Class 1 lasers Installing a transceiverGigabit Optic Distance Supported for stacking Cabling a fiber optic transceiver Cleaning the fiber optic connectors Testing connectivityTesting connectivity Pinging an IP addressDesired Meaning Testing connectivity Network connection-related LED statesMeaning or Action Tracing a route Troubleshooting network connectionsConfiguration notes Using Virtual Cable Testing to diagnose a cableCommand syntax Viewing the results of the cable analysisSyntax show cable-diag tdr port-num Digital optical monitoringDefines the fields shown in this output Cable statistics This Line DisplaysTroubleshooting network connections Using the temperature sensor Managing temperature settingsDisplaying the temperature Changing temperature warning and shutdown levels Displaying Syslog messages for temperatureManaging temperature settings Syntax temperature warning stack-unit valueSyntax fan-threshold speed-3 mp lowest value highest value Changing the shutdown temperatureCommand Changing the temperature polling interval Displaying PowerConnect B-FCX CPU usageRemoving MAC address entries Syntax chassis poll-time stack-idvalueHardware maintenance schedule Hardware maintenance scheduleReplacing a copper or fiber optic module Removing a copper or fiber optic moduleCabling a fiber optic module Cleaning the fiber optic connectorsReplacing a copper or fiber optic module Replacing a copper or fiber optic module Physical dimensions and weight Hardware specificationsEnvironmental considerations Operating EnvironmentStorage Temperature Storage Humidity Storage Altitude Hardware specificationsCooling system and fans Storage environmentAir Inflow Air outlet Mgmt Serial Console port pinouts Pinouts and signallingRange meters Cable Type Connector TypeMicrons MHz*km or AC power supply specifications Power cordsHardware specifications Cable length summary Hardware specifications Power and cooling problems Diagnosing switch indicatorsInstallation Troubleshooting chartDiagnosing switch indicators In-band accessIndustry Canada statement USA FCC CFR 47 Part 15 WarningEurope and Australia Cispr 22 Class a Warning Japan VcciKorea Japan power cordRussia Class a statementRegulatory compliance Regulatory complianceCertifications Regulatory compliance Vorsicht Devices near the input power connectors Never leave tools inside the chassis Gefahr Device PowerConnect B-FCX Switch Hardware Installation Guide