Quick Start
Interface Connectors
Interface Connectors
The following are the Adit 3200 interface connectors:
Front of Adit
z(1) DS1 WAN port
z(1)
z(4)
Back of Adit
z
zPower input connector
zGround connector
Grounding the Unit
WARNING! THE ADIT 3200 IS REQUIRED TO BE PERMANENTLY GROUNDED FOR THE PROTECTION OF USERS AND SERVICE PERSONNEL.
Chassis ground is located on the back of the unit. To ground the unit:
1.Connect a minimum 14 AWG ground wire with a #8 ring tongue terminal (not included) to the chassis ground on the back of the unit. Secure with the
Chassis Ground
2.Connect the opposite end of the ground wire to a suitable earth grounding point such as a building grounding electrode, metal water pipe, or metal building
structure that is in compliance with article 250 of NEC.
12 | Adit 3200 - Release 1.6 |