Carrier Access quick start Basic Configuration, Setup Adit 3200 for access via Web-Browser

Page 22

Quick Start

Basic Configuration

Basic Configuration

The following configuration is divided into logical sections, where each section configures an additional function. The first must be configured before the second and so forth, however, you may stop at any section and not add the following feature.

NOTE: The order in which commands are entered can affect the successful provisioning of the Adit 3200.

zSetup Adit 3200 for access via Web-Browser

zRestore Factory Defaults

zModify Default Admin User

zConfigure Ethernet WAN Interface

zConfigure Serial 1 as WAN

Setup Adit 3200 for access via Web-Browser

The following steps will configure the Adit 3200 to allow access to the Web Browser for configuration, through one of the 4 10/100Base-T LAN connections.

Note: for LAN access, no additional configuration is required to access the Adit using the web browser. To configure the WAN access:

1.Connect to the CLI via the DB-9 RS-232. See Setting up a CLI Connection on page 19.

2.Enable the remote admin WAN access with the following command sequence:

Command

Description

Username: admin

Log into the system (username and password).

Password: ********

 

Adit 3200> enable

Enter the Privileged mode.

Password: ********

Enter password for the Privileged mode.

#configure terminal

Enter the Configuration mode.

(config)# remote-admin web

Enable remote web admin.

primary-port enable

 

22

Adit 3200 - Release 1.6

Image 22 Contents
Adit Page Quick Start Guide Installation Environment Electrostatic Discharge ESD PrecautionsUnpacking and Inspection User Safety InstallationCompliant Installation Wall Mounting Rack Mounting Optional Feature To rack mount the Adit 3000, follow the instructions belowTray Slide Adit 3104, 3200, 3300 and 3400 Battery Backup Front Chassis OverviewBack Back of Adit Interface ConnectorsFront of Adit Grounding the UnitTo connect AC power PowerBattery Connection To connect -48 VDC powerRS-232 Craft Port Female DB-9 Direction DescriptionPin Name Description DS1/E1 Connection PortsState Description Reset Button 10/100Base-TX EthernetAlarm/Status LEDs Web-Based Management To access the management consoleCommand Description #show interface ethernet 2 Eth WANSetting up a CLI Connection Set the New-line/Transmit value CR+LFLog Key Enabled Software Features Adit 3200 show versionBasic Configuration Setup Adit 3200 for access via Web-BrowserRestore Factory Defaults Select Restore DefaultsModify Default Admin User Quick Start Configure Ethernet WAN Interface Web-browserSelect Apply to apply the new settings Configure Serial 1 as WAN Set Network to WAN