system contact

G

Set switch system

switch(config)#system contact

[System Contact]

 

contact window string

xxx

 

 

 

switch>show system-info

show system-info

E

Show system

 

 

information

 

 

 

 

switch(config)#ip address

ip address

G

Configure the IP

[Ip-address]

 

address of switch

192.168.1.1 255.255.255.0

[Subnet-mask]

 

 

192.168.1.254

[Gateway]

 

 

 

 

 

 

switch(config)#ip dhcp

ip dhcp

G

Enable DHCP client

 

 

function of switch

 

 

 

 

switch#show ip

show ip

P

Show IP information of

 

 

switch

 

 

 

 

switch(config)#no ip dhcp

no ip dhcp

G

Disable DHCP client

 

 

function of switch

 

 

 

 

switch(config)#reload

reload

G

Halt and perform a cold

 

 

restart

switch(config)#default

default

G

Restore to default

 

 

 

switch(config)#admin username

admin username

G

Changes a login

[Username]

 

username.

xxxxxx

 

 

(maximum 10 words)

 

 

 

 

switch(config)#admin password

admin password

G

Specifies a password

[Password]

 

(maximum 10 words)

xxxxxx

 

 

 

switch#show admin

show admin

P

Show administrator

 

 

information

 

 

 

 

switch(config)#dhcpserver enable

dhcpserver enable

G

Enable DHCP Server

 

 

 

switch(config)#no dhcpserver

Dhcpserver disable

G

Disable DHCP Server

 

 

 

switch(config)#dhcpserver lowip

dhcpserver lowip

G

Configure low IP

[Low IP]

 

address for IP pool

192.168.1.100

 

 

 

switch(config)#dhcpserver highip

dhcpserver highip

G

Configure high IP

[High IP]

 

address for IP pool

192.168.1.200

 

 

 

switch(config)#dhcpserver

dhcpserver subnetmask

G

Configure subnet

[Subnet mask]

 

mask for DHCP clients

subnetmask 255.255.255.0

 

 

 

switch(config)#dhcpserver

dhcpserver gateway

G

Configure gateway for

[Gateway]

 

DHCP clients

gateway 192.168.1.254

 

 

 

switch(config)#dhcpserver dnsip

dhcpserver dnsip

G

Configure DNS IP for

 

 

 

 

28

Manual Documentation Number: EIR618-2SFP-T_5107m

 

 

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax

815-433-5104www.bb-elec.com

 

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444

– Fax +353 91-792445www.bb-europe.com

Image 40
Contents Product Description Page Eighteen Port Managed Industrial Ethernet Switches Firmware Version V1.07Kernel Version V2.07FCC Warning Page Content Console Management About Web-based Management Preparing for Web Management Port Mirroring Rate Limiting Vlan configuration 101 102Page Features Introduction¾ Port Based Vlan ¾ 802.1 Q Tag Vlan ¾ GvrpSoftware Specification ManagementPort Trunk with Spanning treeQuality of service Class of serviceLogin Security Relay AlarmPackage Contents Physical Dimension Front Panel of the industrial switchFront Panel D x H 2.83 x 4.13 x 5.98 in 7.2mm x 10.5mm x 15.2 cmTop Panel of the industrial switch Top ViewLED Indicators Ports Straight Through Cable Schematic Cross Over Cable Schematic „ Gigabit Copper/SFP Mini-GBIC combo portCabling Insert the fiber cable into the transceiver Remove LC connector Wiring the Power Inputs Wiring the Fault Alarm Contact Rear Panel of the switch DIN-Rail DIN-Rail MountingManual Documentation Number EIR618-2SFP-T5107m Panel Mounting Hardware Installation Installation StepsNetwork Application Ring ApplicationCoupling Ring Application Dual Homing Application Connecting to the Console Port DB9 Connector RJ-45 ConnectorPin Assignment Orange/White Green/White Blue Blue/White Brown/WhiteLogin in the Console Interface Settings of communication parametersCLI command interface Console login interfaceCLI Management Commands Level Commands Set List System Commands SetSystem Name System LocationPassword System ContactIp-address Subnet-maskHours IP addressPort Commands Set PortidFull half 101001000autoEnable Disable ValueTrunk Commands Set Vlan Commands Set GroupIDGroup Name PortNumbersGroupName PortNumber~61440 Spanning Tree Commands SetSeconds Spanning-tree Hello-time secondsForward-time seconds Stp-path-costAutoTrueFalse TrueFalseQOS Commands Set Igmp Commands SetMac / Filter Table Commands Set Snmp Commands Set Name NoAuthNoPrivAuthNoP RivAuthPrivExactPrifix Read View Name Write View Name Notify ViewPort Mirroring Commands Set Remove specifiedMibview table View Name SNMPV3 agentPort ID 802.1x Commands SetWords Sec Disable reject acceptNumber SystemLog, Smtp and Event Commands Set Tftp Commands SetAuthorize Clientserverboth AccountIndex Email address SystemlogSMTPBothSntp Commands Set Start time End timeRing Commands Set MinuteTimezone 1st Ring Port 2nd RingControl Port Coupling PortDual Homing Port About Web-based Management Preparing for Web ManagementSystem Login System Information System information interfaceIP Configuration IP configuration interfaceDhcp Server System configuration Dhcp Server Configuration interfaceDhcp Server Client Entries Dhcp Client information is displayedDhcp Client Entries interface Dhcp Server Port and IP BindingsPort and IP Bindings interface Tftp Update Firmware Tftp Restore ConfigurationUpdate Firmware interface Restore Configuration interfaceSystem Event Log Syslog Configuration Tftp Backup ConfigurationTftp Server IP Address Enter the Tftp server IP System Event Log Smtp Configuration Syslog Configuration interfaceSystem Event Log Event Configuration Smtp Configuration interfaceEvent Configuration interface Sntp Configuration Fault Relay AlarmFault Relay Alarm interface Local Time Zone Conversion from UTC Time at 1200 UTC Switch Timer Displays the current time Click Apply Daylight Saving Offset mins Enter the offset in minutesSntp Configuration interface IP SecurityUser Authentication interface User AuthenticationIP Security interface Port Statistics Port Statistics interfacePort Control Aggregator setting Port TrunkButton to add Port. To remove unwanted ports, select Port and clickDelete to delete Trunk Group State Activity Aggregator InformationDisplays static trunk group information Port Trunk State Activity interface Port Mirroring Port Trunk Port Mirroring interfaceRate Limiting Rate Limiting interfaceVlan configuration Port-based Vlan Vlan configurationVlan Configuration interface Vlan Port Based interface VLAN-Port Based Add interfaceUse Button to delete the Vlan Use Button to modify group name, Vlan ID, or add/removeMembers of the existing Vlan group VLAN-Port Based Edit/Delete interface„ Hybrid Link Both Access Link and Trunk Link 802.1Q VlanGroup Configuration 802.1Q Vlan interface„ You can modify the Vlan group name and Vlan ID Group Configuration interface„ Click Apply button Rstp System Configuration Rapid Spanning TreeRstp Port Configuration Rstp System Configuration interfaceRstp Port Configuration interface System Configuration Snmp Configuration„ Community Strings Trap Configuration Snmp System Configuration interfaceSNMPV3 Configuration „ Privacy Password Enter the private passwordContext Table User ProfileSnmp V3 configuration interface Group Table Access TableMIBview Table QoS Configuration QoS Policy and Priority Type„ Click Remove to remove an unwanted context name „ QoS Policy select the QoS policy ruleQoS Configuration interface Port-based PriorityIgmp Configuration COS ConfigurationTOS Configuration „ Click Apply button to make the settings effectiveMessage sent from the querier Igmp router or switch Message DescriptionQuery ReportRing Ring Interface 802.1x System Configuration interface 802.1X/Radius ConfigurationSecurity 802.1x Port Configuration 802.1x Per Port Setting interfaceMisc Configuration 802.1x Misc Configuration interfaceMAC Address Table Use the MAC address table to ensure the port securityStatic MAC Addresses interface MAC Filtering interfaceFactory Default All MAC Address interfaceSave Configuration System RebootClick Save to save the configuration to the flash memory Click Reboot to reboot the systemTrouble shooting 101Standard ProtocolTransfer Rate MAC address„ LC Single mode 9/125um Back-plane Power SupplyPower Consumption InstallSafety Stability testingCE/EN60950-1 IEC60068-2-32 Free fall IEC60068-2-27 Shock IEC60068-2-6 Vibration