Zhone Technologies Z-PLEX-10-24-DOC-SC manual Installing the product Installing the Z-Plex

Page 20

Installing the product

Installing the Z-Plex

1.Never install telephone wiring during a lightning storm.

2.Never install this product in a wet location.

3.Never install telephone jacks in wet locations unless the jack is specifically designed for this purpose only.

4.Never touch uninsulated telephone wires or terminals unless the telephone line has first been disconnected at the network interface.

5.Use caution when installing or modifying telephone lines.

6.Never attempt to service this product unless you are an authorized service technician. Doing so can result in injury or damage to the unit and void all warranties.

7.This product is intended for use with a three-wire grounding type plug. This is a safety feature. Equipment grounding is vital to ensure safe operation. Do not defeat the purpose of the grounding type plug by modifying the plug or using an adapter.

8.Prior to installation use an outlet tester or a voltmeter to check the AC receptacle for the presence of earth ground. If the receptacle is not properly grounded, the installation must not continue until a qualified electrician has corrected the problem. In addition, a connection for earth or safety grounding is provided on the chassis. It is a #6 threaded stud located next to the AC inlet receptacle.

9.Slots and openings in the product are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.

10.DO NOT allow anything to rest on the power cord and do not locate the product where persons could step or walk on the power cord.

11.DO NOT attempt to service this product yourself. To avoid exposure to dangerous high voltage points or other risks, refer all servicing to qualified service personnel.

12.Special cables, which may be required by the regulatory inspection authority for the installation site, are the responsibility of the buyer.

13.When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance.

14.A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings. If products installed in separate buildings are interconnected, the voltage potential may cause a hazardous condition. Consult a qualified electrical consultant to determine whether or not this phenomenon exists and, if necessary, implement corrective action prior to interconnecting the product.

2-4 \ Zhone Technologies

Image 20
Contents Plex User’s Guide Trademarks Regulatory Information FCC Part 68 Regulatory InformationCountry-Specific Regulatory Compliance Information Industrie Canada RequirementsPage Page Contents Chapter Configuring the ZPlex Chapter DiagnosticsAppendix a Alphabetical Reference \ Zhone Technologies Product overview Introduction Product overviewFeatures Features IntroductionBenefits TR-08Introduction Managing the Z-Plex Managing the Z-PlexSnmp Product specifications Product specifications Introduction2 CLI TftpIntroduction Product specifications AMI, B8ZSProduct specifications Introduction Back panel Installing the Z-Plex Product descriptionProduct description Unpacking the product Front panelPacking materials Kit of partsInstalling the product Important Safety InstructionsInstalling the product Installing the Z-Plex Installing the Z-Plex Rack mounting Rack mountingWall mounting Locating the product on a desktop Installing the Z-PlexLocating the product on a desktop Backpanel connectors Connector typeElectrical Installation Connector type DCE DB25 data port female connector Data port connector pinoutsData port connector pinouts Electrical Installation Pair female amphenol connector 1 FXO/FXS connectorsElectrical Installation Data port connector pinouts Power requirements 2 RJ48 connectorPower requirements Electrical Installation T1 connector pinoutsAlarm Power installationElectrical Installation Alarm AC power installationGrounding requirements Electrical Installation Grounding requirementsRecommended cables Electrical Installation CablingCabling Cabling Electrical Installation Using the command line interface Configuring the Z-Plex Using the command line interfaceQuick start system configuration Quick start system configuration Configuring the Z-PlexConfiguring the Z-Plex Quick start system configuration Logging in and out of the system Setting the dateConfiguring a management interface Configuring the local management channel Configuring the DS0 management channelConfiguring the Ethernet management channel Configuring the IP over FDL management channelConfiguring Snmp Configuring the Z-Plex Configuring SnmpConfiguring system contact information Configuring T1 interfaces Configuring the Z-Plex Configuring T1 interfacesConfiguring a T1 drop and insert interface Configuring FXS portsConfiguring FXO ports Configuring the Z-Plex Configuring FXO portsConfiguring the V.35 data port Configuring the V.35 data port Configuring the Z-PlexAdding and deleting network routes Configuring the Z-Plex Adding and deleting routesAdding and deleting routes Adding and deleting host routes Example routing configurationAdding and deleting routes Configuring the Z-Plex Example routing configuration Displaying routesRoute Display Values Displaying host routesSystem maintenance commands Rebooting the systemConfiguring the Z-Plex System maintenance commands Displaying flash informationDisplaying list of alarms Displaying and clearing list of history alarmsSystem maintenance commands Configuring the Z-Plex Displaying timeslot usageActivating code in bank Tftp downloading18 \ Zhone Technologies Diagnostics T1 loopbacks T1 loopbacksT1 loopbacks Diagnostics T1 loopbacksBER testing Diagnostics BER testingActivating a BER test for an entire T1 line Activating a BER test for individual time slotsData port loopbacks Diagnostics Data port loopbacksTesting FXO and FXS ports Diagnostics Testing FXO and FXS portsTesting FXO and FXS ports Diagnostics FXO and FXS ports loopbackConfiguring FXO loopbacks Configuring FXS loopbacksUsing test mode on the FXO and FXS ports Setting or viewing the transmit Abcd signaling bitsDiagnostics LED indicators LED indicatorsAlarm LED Power LED LED indicators DiagnosticsEthernet LED WAN LEDsConfiguration groups Table A-1. Configuration groups in the Z-PlexParameter reference Alphabetical Reference Parameter referenceParameter reference Alphabetical Reference Fxotst Alphabetic reference Allcur AllfarcurAllfartot AllfarintCLK BertBES Ctsdelay ClksrcCode CTSCUR DS0FDL DSRErrins Hdlc FdlipFrame Iphdl INTIpfdl Loop FXO LinelenLofc Loopback T1 Loop FXSLoopback Mode FXO MaskMaskfdl MaskhdlMode FXS Rate NchanPattern Rtlp FXO RlsdRngbk RxAB FXS Rtlp FXSRxAB FXO Schan SESSlip StateState T1 State FXOState FXS Syscontact SysdescrSyslocation SysnameTrcntl FXO Test FXSTOT Trnkc FXS Trcntrl FXSTrnkc FXO TS data port Trstat FXOTrstat FXS TS FXO TS FXSTsbertoff TsbertonTtlp FXO Ttlp FXSType FXO TxAB FXOTxAB FXS Type FXS Type UASWAN WAN FXOCommand reference Error messages Alphabetical Reference Error messagesQueryhalarm RebootError messages Alphabetical Reference Basic control commands Table A-4. Basic control commandsCLI reference Alphabetical Reference CLI referenceMovement and search commands CLI reference Alphabetical ReferenceTable A-6. Insert and change commands Insert and change commandsTable A-5. Movement and search commands Delete commands Put and undo commandsTable A-7. Delete commands Table A-8. Put and undo commandsUndo last command 38 \ Zhone Technologies Index LED 194-4 Index-4 / Zhone Technologies WAN LED

Z-PLEX-10-24-DOC-SC specifications

Zhone Technologies is a leading provider of innovative telecommunications and data networking solutions, and the Z-PLEX-10-24-DOC-SC is one of their advanced products designed to meet the demands of modern networking environments. This versatile optical networking solution is ideal for service providers looking to deliver high-speed broadband services to residential and business customers.

The Z-PLEX-10-24-DOC-SC provides an impressive 24-port capability, making it a robust choice for deployment in various settings, from small community networks to larger metropolitan areas. Its compact design allows for easy integration into existing systems, minimizing the need for extensive reconfiguration or additional space. The system is geared towards enabling efficient fiber deployment and helps operators enhance their service offerings while reducing operational expenses.

One of the main features of the Z-PLEX-10-24-DOC-SC is its support for Dense Wavelength Division Multiplexing (DWDM) technology. This allows multiple optical signals to be transmitted simultaneously over a single optical fiber, greatly increasing the capacity and efficiency of the network. By leveraging DWDM, service providers can maximize their existing infrastructure without the need for extensive new fiber installation.

Another significant characteristic of the Z-PLEX-10-24-DOC-SC is its scalability. The system is designed to grow with the telecommunication needs of operators, supporting various service types, including voice, video, and data, without sacrificing performance or quality. This flexibility ensures that as users' demands evolve, the Z-PLEX-10-24-DOC-SC can adapt to meet these changing requirements.

The unit also incorporates advanced management features, supported by Zhone's innovative software tools. These tools facilitate network monitoring, configuration, and maintenance, allowing operators to optimize their operations and provide better service to their end-users. This end-to-end management capability is essential in today’s fast-paced digital landscape, where customer satisfaction is paramount.

In summary, the Zhone Technologies Z-PLEX-10-24-DOC-SC is a powerful optical networking solution that combines advanced technology with scalability and efficiency. It empowers service providers to deliver high-quality broadband services while optimizing their resources. With its DWDM support, compact design, and robust management tools, the Z-PLEX-10-24-DOC-SC stands out as a reliable choice for modern telecommunications infrastructure.