Zhone Technologies Z-PLEX-10-24-DOC-SC Configuring the Z-Plex Quick start system configuration

Page 33

Configuring the Z-Plex

Quick start system configuration

3.Change the default user password. For example:

user> SET USER:PASSWD:zplex321

The password can be from 7 to 12 characters long. The password is used any time you log into the Z-Plex unit to manage it.

4.Configure SNMP agent addresses, community strings, and enable traps, if necessary. For example:

user> SET CPUCFG:IPHOST1:1:192.168.10.21 user> SET CPUCFG:IPHOST2:1:192.168.10.22 user> SET CPUCFG:RDCOMSTRING:1:W23rw user> SET CPUCFG:WTCOMSTRING:1:q34mw

5.Configure a management interface, either DS024, Ethernet, or IP over FDL. (FDL over typically used only for a connection to a Premisys IMACs). For example, the following commands configure a DS0 management interface:

user> SET T1CFG:DS0:1:ON

user> SET CPUCFG:MASKHDL:1:255.255.255.252 user> SET CPUCFG:IPHDL:1:192.168.8.22

6.Assign static routes if necessary. For example, the following command configures a static host route to 62.6.5.34 with a gateway of 192.168.8.21 (the IP address of the Z-Plex Ethernet interface):

SET ROUTE:ADDHOSTRT:10:62.6.5.34:192.168.8.21

Static routes might be necessary to telnet into the Z-Plex to manage it.

7.Set the date on the system. For example, the following commands prompt you for the system date:

user> SET DATE

The system prompts you for the date in mm:dd:yyyy hh/mm/ss format.

8.Configure basic system contact information such as name, location, and contact.

user> SET SYSTEM:SYSCONTACT:Scott_Berman user> SET SYSTEM:SYSNAME:ZPlex-10-2-1

user> SET SYSTEM:SYSLOCATION:10th_flr-rack_2-unit_1

9.Reboot the system:

user> REBOOT

Zhone Technologies / 4-3

Image 33
Contents Plex User’s Guide Trademarks FCC Part 68 Regulatory Information Regulatory InformationIndustrie Canada Requirements Country-Specific Regulatory Compliance InformationPage Page Contents Chapter Diagnostics Chapter Configuring the ZPlexAppendix a Alphabetical Reference \ Zhone Technologies Introduction Product overview Product overviewFeatures Introduction FeaturesBenefits TR-08Managing the Z-Plex SnmpIntroduction Managing the Z-Plex Product specifications Introduction Product specifications2 CLI TftpAMI, B8ZS Introduction Product specificationsProduct specifications Introduction Installing the Z-Plex Product description Product descriptionBack panel Front panel Unpacking the productPacking materials Kit of partsImportant Safety Instructions Installing the productInstalling the product Installing the Z-Plex Rack mounting Installing the Z-Plex Rack mountingLocating the product on a desktop Installing the Z-Plex Locating the product on a desktopWall mounting Connector type Electrical Installation Connector typeBackpanel connectors Data port connector pinouts Data port connector pinouts Electrical InstallationDCE DB25 data port female connector 1 FXO/FXS connectors Electrical Installation Data port connector pinoutsPair female amphenol connector 2 RJ48 connector Power requirementsPower requirements Electrical Installation T1 connector pinoutsPower installation AlarmElectrical Installation Alarm AC power installationGrounding requirements Grounding requirements Electrical InstallationElectrical Installation Cabling CablingRecommended cables Cabling Electrical Installation Configuring the Z-Plex Using the command line interface Using the command line interfaceQuick start system configuration Configuring the Z-Plex Quick start system configurationConfiguring the Z-Plex Quick start system configuration Setting the date Configuring a management interfaceLogging in and out of the system Configuring the DS0 management channel Configuring the local management channelConfiguring the Ethernet management channel Configuring the IP over FDL management channelConfiguring Snmp Configuring system contact informationConfiguring Snmp Configuring the Z-Plex Configuring the Z-Plex Configuring T1 interfaces Configuring T1 interfacesConfiguring FXS ports Configuring a T1 drop and insert interfaceConfiguring the Z-Plex Configuring FXO ports Configuring FXO portsConfiguring the V.35 data port Configuring the Z-Plex Configuring the V.35 data portConfiguring the Z-Plex Adding and deleting routes Adding and deleting routesAdding and deleting network routes Example routing configuration Adding and deleting routes Configuring the Z-PlexAdding and deleting host routes Displaying routes Example routing configurationDisplaying host routes Route Display ValuesRebooting the system System maintenance commandsConfiguring the Z-Plex System maintenance commands Displaying flash informationDisplaying and clearing list of history alarms Displaying list of alarmsSystem maintenance commands Configuring the Z-Plex Displaying timeslot usageTftp downloading Activating code in bank18 \ Zhone Technologies T1 loopbacks Diagnostics T1 loopbacksT1 loopbacks T1 loopbacks DiagnosticsDiagnostics BER testing BER testingActivating a BER test for an entire T1 line Activating a BER test for individual time slotsData port loopbacks Data port loopbacks DiagnosticsDiagnostics Testing FXO and FXS ports Testing FXO and FXS portsFXO and FXS ports loopback Testing FXO and FXS ports DiagnosticsConfiguring FXS loopbacks Configuring FXO loopbacksSetting or viewing the transmit Abcd signaling bits Using test mode on the FXO and FXS portsLED indicators Alarm LEDDiagnostics LED indicators LED indicators Diagnostics Power LEDEthernet LED WAN LEDsTable A-1. Configuration groups in the Z-Plex Configuration groupsParameter reference Alphabetical Reference Parameter referenceParameter reference Alphabetical Reference Fxotst Alphabetic reference Allfarcur AllcurAllfartot AllfarintBert BESCLK Clksrc CtsdelayCode CTSDS0 CURDSR ErrinsFDL Fdlip FrameHdlc INT IpfdlIphdl Linelen LofcLoop FXO Loop FXS LoopbackLoopback T1 Mask Mode FXOMaskfdl MaskhdlMode FXS Nchan PatternRate Rlsd RngbkRtlp FXO Rtlp FXS RxAB FXORxAB FXS SES SchanSlip StateState FXO State FXSState T1 Sysdescr SyscontactSyslocation SysnameTest FXS TOTTrcntl FXO Trcntrl FXS Trnkc FXOTrnkc FXS Trstat FXO Trstat FXSTS data port TS FXS TS FXOTsberton TsbertoffTtlp FXO Ttlp FXSTxAB FXO TxAB FXSType FXO Type FXS UAS TypeWAN WAN FXOCommand reference Alphabetical Reference Error messages Error messagesQueryhalarm RebootError messages Alphabetical Reference Table A-4. Basic control commands Basic control commandsCLI reference Alphabetical Reference CLI referenceCLI reference Alphabetical Reference Movement and search commandsInsert and change commands Table A-5. Movement and search commandsTable A-6. Insert and change commands Put and undo commands Delete commandsTable A-7. Delete commands Table A-8. Put and undo commandsUndo last command 38 \ Zhone Technologies Index LED 194-4 Index-4 / Zhone Technologies WAN LED

Z-PLEX-10-24-DOC-SC specifications

Zhone Technologies is a leading provider of innovative telecommunications and data networking solutions, and the Z-PLEX-10-24-DOC-SC is one of their advanced products designed to meet the demands of modern networking environments. This versatile optical networking solution is ideal for service providers looking to deliver high-speed broadband services to residential and business customers.

The Z-PLEX-10-24-DOC-SC provides an impressive 24-port capability, making it a robust choice for deployment in various settings, from small community networks to larger metropolitan areas. Its compact design allows for easy integration into existing systems, minimizing the need for extensive reconfiguration or additional space. The system is geared towards enabling efficient fiber deployment and helps operators enhance their service offerings while reducing operational expenses.

One of the main features of the Z-PLEX-10-24-DOC-SC is its support for Dense Wavelength Division Multiplexing (DWDM) technology. This allows multiple optical signals to be transmitted simultaneously over a single optical fiber, greatly increasing the capacity and efficiency of the network. By leveraging DWDM, service providers can maximize their existing infrastructure without the need for extensive new fiber installation.

Another significant characteristic of the Z-PLEX-10-24-DOC-SC is its scalability. The system is designed to grow with the telecommunication needs of operators, supporting various service types, including voice, video, and data, without sacrificing performance or quality. This flexibility ensures that as users' demands evolve, the Z-PLEX-10-24-DOC-SC can adapt to meet these changing requirements.

The unit also incorporates advanced management features, supported by Zhone's innovative software tools. These tools facilitate network monitoring, configuration, and maintenance, allowing operators to optimize their operations and provide better service to their end-users. This end-to-end management capability is essential in today’s fast-paced digital landscape, where customer satisfaction is paramount.

In summary, the Zhone Technologies Z-PLEX-10-24-DOC-SC is a powerful optical networking solution that combines advanced technology with scalability and efficiency. It empowers service providers to deliver high-quality broadband services while optimizing their resources. With its DWDM support, compact design, and robust management tools, the Z-PLEX-10-24-DOC-SC stands out as a reliable choice for modern telecommunications infrastructure.