Zhone Technologies Z-PLEX-10-24-DOC-SC manual Fxotst

Page 61

Alphabetical Reference

Parameter reference

Table A-1. Configuration groups in the Z-Plex (Continued)

Group

Index

Description

Parameters

 

 

 

 

FXOTST

A single value

Test mode for FXO ports.

RXAB

 

between 1 and

 

TEST

 

24, or a range of

 

TRCNTRL

 

values.

 

TRSTAT

 

 

 

TXAB

 

 

 

 

FXSCFG

A single value

FXS port configuration, including

LOOP

 

between 1 and

state, mode, and type.

MODE

 

24, or a range of

 

RNGBK

 

values.

 

RTLP

 

 

 

STATE

 

 

 

TRNKC

 

 

 

TS

 

 

 

TTLP

 

 

 

TYPE

 

 

 

WAN

 

 

 

 

FXSTST

A single value

Test mode for FXS ports.

RXAB

 

between 1 and

 

TEST

 

24, or a range of

 

TRCNTRL

 

values.

 

TRSTAT

 

 

 

TXAB

 

 

 

 

PMCUR

1A single value

Current statistics for the T1 interfaces.

ALLCUR

 

between 1 and

 

BES

 

24, or a range of

 

ES

 

values.

 

LOFC

 

 

 

SES

 

 

 

SLIP

 

 

 

UA

 

 

 

 

PMINT

A single value

Interval statistics for the T1 interfaces.

ALLINT

 

between 1 and

 

BES

 

24, or a range of

 

ES

 

values.

 

LOFC

 

 

 

SES

 

 

 

SLIP

 

 

 

UAS\

 

 

 

 

Zhone Technologies / A-3

Image 61
Contents Plex User’s Guide Trademarks FCC Part 68 Regulatory Information Regulatory InformationIndustrie Canada Requirements Country-Specific Regulatory Compliance InformationPage Page Contents Chapter Diagnostics Chapter Configuring the ZPlexAppendix a Alphabetical Reference \ Zhone Technologies Introduction Product overview Product overviewFeatures Introduction FeaturesBenefits TR-08Snmp Managing the Z-PlexIntroduction Managing the Z-Plex Product specifications Introduction Product specifications2 CLI TftpAMI, B8ZS Introduction Product specificationsProduct specifications Introduction Product description Installing the Z-Plex Product descriptionBack panel Front panel Unpacking the productPacking materials Kit of partsImportant Safety Instructions Installing the productInstalling the product Installing the Z-Plex Rack mounting Installing the Z-Plex Rack mountingLocating the product on a desktop Locating the product on a desktop Installing the Z-PlexWall mounting Electrical Installation Connector type Connector typeBackpanel connectors Data port connector pinouts Electrical Installation Data port connector pinoutsDCE DB25 data port female connector Electrical Installation Data port connector pinouts 1 FXO/FXS connectorsPair female amphenol connector 2 RJ48 connector Power requirementsPower requirements Electrical Installation T1 connector pinoutsPower installation AlarmElectrical Installation Alarm AC power installationGrounding requirements Grounding requirements Electrical InstallationCabling Electrical Installation CablingRecommended cables Cabling Electrical Installation Configuring the Z-Plex Using the command line interface Using the command line interfaceQuick start system configuration Configuring the Z-Plex Quick start system configurationConfiguring the Z-Plex Quick start system configuration Configuring a management interface Setting the dateLogging in and out of the system Configuring the DS0 management channel Configuring the local management channelConfiguring the Ethernet management channel Configuring the IP over FDL management channelConfiguring system contact information Configuring SnmpConfiguring Snmp Configuring the Z-Plex Configuring the Z-Plex Configuring T1 interfaces Configuring T1 interfacesConfiguring FXS ports Configuring a T1 drop and insert interfaceConfiguring the Z-Plex Configuring FXO ports Configuring FXO portsConfiguring the V.35 data port Configuring the Z-Plex Configuring the V.35 data portAdding and deleting routes Configuring the Z-Plex Adding and deleting routesAdding and deleting network routes Adding and deleting routes Configuring the Z-Plex Example routing configurationAdding and deleting host routes Displaying routes Example routing configurationDisplaying host routes Route Display ValuesRebooting the system System maintenance commandsConfiguring the Z-Plex System maintenance commands Displaying flash informationDisplaying and clearing list of history alarms Displaying list of alarmsSystem maintenance commands Configuring the Z-Plex Displaying timeslot usageTftp downloading Activating code in bank18 \ Zhone Technologies T1 loopbacks Diagnostics T1 loopbacksT1 loopbacks T1 loopbacks DiagnosticsDiagnostics BER testing BER testingActivating a BER test for an entire T1 line Activating a BER test for individual time slotsData port loopbacks Data port loopbacks DiagnosticsDiagnostics Testing FXO and FXS ports Testing FXO and FXS portsFXO and FXS ports loopback Testing FXO and FXS ports DiagnosticsConfiguring FXS loopbacks Configuring FXO loopbacksSetting or viewing the transmit Abcd signaling bits Using test mode on the FXO and FXS portsAlarm LED LED indicatorsDiagnostics LED indicators LED indicators Diagnostics Power LEDEthernet LED WAN LEDsTable A-1. Configuration groups in the Z-Plex Configuration groupsParameter reference Alphabetical Reference Parameter referenceParameter reference Alphabetical Reference Fxotst Alphabetic reference Allfarcur AllcurAllfartot AllfarintBES BertCLK Clksrc CtsdelayCode CTSDS0 CURErrins DSRFDL Frame FdlipHdlc Ipfdl INTIphdl Lofc LinelenLoop FXO Loopback Loop FXSLoopback T1 Mask Mode FXOMaskfdl MaskhdlMode FXS Pattern NchanRate Rngbk RlsdRtlp FXO RxAB FXO Rtlp FXSRxAB FXS SES SchanSlip StateState FXS State FXOState T1 Sysdescr SyscontactSyslocation SysnameTOT Test FXSTrcntl FXO Trnkc FXO Trcntrl FXSTrnkc FXS Trstat FXS Trstat FXOTS data port TS FXS TS FXOTsberton TsbertoffTtlp FXO Ttlp FXSTxAB FXS TxAB FXOType FXO Type FXS UAS TypeWAN WAN FXOCommand reference Alphabetical Reference Error messages Error messagesQueryhalarm RebootError messages Alphabetical Reference Table A-4. Basic control commands Basic control commandsCLI reference Alphabetical Reference CLI referenceCLI reference Alphabetical Reference Movement and search commandsTable A-5. Movement and search commands Insert and change commandsTable A-6. Insert and change commands Put and undo commands Delete commandsTable A-7. Delete commands Table A-8. Put and undo commandsUndo last command 38 \ Zhone Technologies Index LED 194-4 Index-4 / Zhone Technologies WAN LED

Z-PLEX-10-24-DOC-SC specifications

Zhone Technologies is a leading provider of innovative telecommunications and data networking solutions, and the Z-PLEX-10-24-DOC-SC is one of their advanced products designed to meet the demands of modern networking environments. This versatile optical networking solution is ideal for service providers looking to deliver high-speed broadband services to residential and business customers.

The Z-PLEX-10-24-DOC-SC provides an impressive 24-port capability, making it a robust choice for deployment in various settings, from small community networks to larger metropolitan areas. Its compact design allows for easy integration into existing systems, minimizing the need for extensive reconfiguration or additional space. The system is geared towards enabling efficient fiber deployment and helps operators enhance their service offerings while reducing operational expenses.

One of the main features of the Z-PLEX-10-24-DOC-SC is its support for Dense Wavelength Division Multiplexing (DWDM) technology. This allows multiple optical signals to be transmitted simultaneously over a single optical fiber, greatly increasing the capacity and efficiency of the network. By leveraging DWDM, service providers can maximize their existing infrastructure without the need for extensive new fiber installation.

Another significant characteristic of the Z-PLEX-10-24-DOC-SC is its scalability. The system is designed to grow with the telecommunication needs of operators, supporting various service types, including voice, video, and data, without sacrificing performance or quality. This flexibility ensures that as users' demands evolve, the Z-PLEX-10-24-DOC-SC can adapt to meet these changing requirements.

The unit also incorporates advanced management features, supported by Zhone's innovative software tools. These tools facilitate network monitoring, configuration, and maintenance, allowing operators to optimize their operations and provide better service to their end-users. This end-to-end management capability is essential in today’s fast-paced digital landscape, where customer satisfaction is paramount.

In summary, the Zhone Technologies Z-PLEX-10-24-DOC-SC is a powerful optical networking solution that combines advanced technology with scalability and efficiency. It empowers service providers to deliver high-quality broadband services while optimizing their resources. With its DWDM support, compact design, and robust management tools, the Z-PLEX-10-24-DOC-SC stands out as a reliable choice for modern telecommunications infrastructure.