Zhone Technologies Z-PLEX-10-24-DOC-SC manual Displaying timeslot usage, Displaying list of alarms

Page 46

System maintenance commands

Configuring the Z-Plex

BANK2

->Software version : ZPLEX10_1.0.0#6

->Checksum : 0x50a78d4c Active bank is 1

4.10.3 Displaying timeslot usage

To display information about the T1 timeslot usage, enter the following command:

user> QUERYTS

TS 24, WAN 1, SERVICE IP

4.10.4 Displaying list of alarms

To display information about the active alarms, enter the following command:

user> QUERYALARM

There are no Active Alarms

4.10.5 Displaying and clearing list of history alarms

To display information about the history alarms, enter the following command:

user> QUERYHALARM

 

 

 

17

 

MINOR

RESET

0:0:0:3

0:0:0:3

17

WAN1

MAJOR

LOF

0:0:9:4

0:0:9:4

18

WAN1

MAJOR

LOF

0:0:9:6

0:0:9:6

3

WAN1

MAJOR

LOS

0:0:8:35

0:0:8:35

4

WAN1

MAJOR

LOF

0:0:8:35

0:0:8:37

5

WAN1

MAJOR

LOF

0:0:8:39

0:0:8:39

6

WAN1

MAJOR

LOF

0:0:8:41

0:0:8:41

7

WAN1

MAJOR

LOF

0:0:8:43

0:0:8:43

8

WAN1

MAJOR

LOF

0:0:8:45

0:0:8:45

9

WAN1

MAJOR

LOF

0:0:8:47

0:0:8:47

10

WAN1

MAJOR

LOF

0:0:8:49 0:0:8:49

11

WAN1

MAJOR

LOF

0:0:8:51 0:0:8:51

12

WAN1

MAJOR

LOF

0:0:8:53 0:0:8:53

13

WAN1

MAJOR

LOF

0:0:8:55 0:0:8:55

14

WAN1

MAJOR

LOF

0:0:8:57 0:0:8:57

15

WAN1

MAJOR

LOF

0:0:8:59 0:0:8:59

To clear the history alarms, enter the following command:

user> CLEARHALARM

4-16 \ Zhone Technologies

Image 46
Contents Plex User’s Guide Trademarks Regulatory Information FCC Part 68 Regulatory InformationCountry-Specific Regulatory Compliance Information Industrie Canada RequirementsPage Page Contents Chapter Configuring the ZPlex Chapter DiagnosticsAppendix a Alphabetical Reference \ Zhone Technologies Product overview Introduction Product overviewBenefits FeaturesFeatures Introduction TR-08Snmp Managing the Z-PlexIntroduction Managing the Z-Plex 2 CLI Product specificationsProduct specifications Introduction TftpIntroduction Product specifications AMI, B8ZSProduct specifications Introduction Product description Installing the Z-Plex Product descriptionBack panel Packing materials Unpacking the productFront panel Kit of partsInstalling the product Important Safety InstructionsInstalling the product Installing the Z-Plex Installing the Z-Plex Rack mounting Rack mountingLocating the product on a desktop Locating the product on a desktop Installing the Z-PlexWall mounting Electrical Installation Connector type Connector typeBackpanel connectors Data port connector pinouts Electrical Installation Data port connector pinoutsDCE DB25 data port female connector Electrical Installation Data port connector pinouts 1 FXO/FXS connectorsPair female amphenol connector Power requirements Electrical Installation Power requirements2 RJ48 connector T1 connector pinoutsElectrical Installation Alarm AlarmPower installation AC power installationGrounding requirements Electrical Installation Grounding requirementsCabling Electrical Installation CablingRecommended cables Cabling Electrical Installation Using the command line interface Configuring the Z-Plex Using the command line interfaceQuick start system configuration Quick start system configuration Configuring the Z-PlexConfiguring the Z-Plex Quick start system configuration Configuring a management interface Setting the dateLogging in and out of the system Configuring the Ethernet management channel Configuring the local management channelConfiguring the DS0 management channel Configuring the IP over FDL management channelConfiguring system contact information Configuring SnmpConfiguring Snmp Configuring the Z-Plex Configuring T1 interfaces Configuring the Z-Plex Configuring T1 interfacesConfiguring a T1 drop and insert interface Configuring FXS portsConfiguring FXO ports Configuring the Z-Plex Configuring FXO portsConfiguring the V.35 data port Configuring the V.35 data port Configuring the Z-PlexAdding and deleting routes Configuring the Z-Plex Adding and deleting routesAdding and deleting network routes Adding and deleting routes Configuring the Z-Plex Example routing configurationAdding and deleting host routes Example routing configuration Displaying routesRoute Display Values Displaying host routesConfiguring the Z-Plex System maintenance commands System maintenance commandsRebooting the system Displaying flash informationSystem maintenance commands Configuring the Z-Plex Displaying list of alarmsDisplaying and clearing list of history alarms Displaying timeslot usageActivating code in bank Tftp downloading18 \ Zhone Technologies Diagnostics T1 loopbacks T1 loopbacksT1 loopbacks Diagnostics T1 loopbacksActivating a BER test for an entire T1 line BER testingDiagnostics BER testing Activating a BER test for individual time slotsData port loopbacks Diagnostics Data port loopbacksTesting FXO and FXS ports Diagnostics Testing FXO and FXS portsTesting FXO and FXS ports Diagnostics FXO and FXS ports loopbackConfiguring FXO loopbacks Configuring FXS loopbacksUsing test mode on the FXO and FXS ports Setting or viewing the transmit Abcd signaling bitsAlarm LED LED indicatorsDiagnostics LED indicators Ethernet LED Power LEDLED indicators Diagnostics WAN LEDsParameter reference Configuration groupsTable A-1. Configuration groups in the Z-Plex Alphabetical Reference Parameter referenceParameter reference Alphabetical Reference Fxotst Alphabetic reference Allfartot AllcurAllfarcur AllfarintBES BertCLK Code CtsdelayClksrc CTSCUR DS0Errins DSRFDL Frame FdlipHdlc Ipfdl INTIphdl Lofc LinelenLoop FXO Loopback Loop FXSLoopback T1 Maskfdl Mode FXOMask MaskhdlMode FXS Pattern NchanRate Rngbk RlsdRtlp FXO RxAB FXO Rtlp FXSRxAB FXS Slip SchanSES StateState FXS State FXOState T1 Syslocation SyscontactSysdescr SysnameTOT Test FXSTrcntl FXO Trnkc FXO Trcntrl FXSTrnkc FXS Trstat FXS Trstat FXOTS data port TS FXO TS FXSTtlp FXO TsbertoffTsberton Ttlp FXSTxAB FXS TxAB FXOType FXO Type FXS WAN TypeUAS WAN FXOCommand reference Queryhalarm Error messagesAlphabetical Reference Error messages RebootError messages Alphabetical Reference CLI reference Basic control commandsTable A-4. Basic control commands Alphabetical Reference CLI referenceMovement and search commands CLI reference Alphabetical ReferenceTable A-5. Movement and search commands Insert and change commandsTable A-6. Insert and change commands Table A-7. Delete commands Delete commandsPut and undo commands Table A-8. Put and undo commandsUndo last command 38 \ Zhone Technologies Index LED 194-4 Index-4 / Zhone Technologies WAN LED

Z-PLEX-10-24-DOC-SC specifications

Zhone Technologies is a leading provider of innovative telecommunications and data networking solutions, and the Z-PLEX-10-24-DOC-SC is one of their advanced products designed to meet the demands of modern networking environments. This versatile optical networking solution is ideal for service providers looking to deliver high-speed broadband services to residential and business customers.

The Z-PLEX-10-24-DOC-SC provides an impressive 24-port capability, making it a robust choice for deployment in various settings, from small community networks to larger metropolitan areas. Its compact design allows for easy integration into existing systems, minimizing the need for extensive reconfiguration or additional space. The system is geared towards enabling efficient fiber deployment and helps operators enhance their service offerings while reducing operational expenses.

One of the main features of the Z-PLEX-10-24-DOC-SC is its support for Dense Wavelength Division Multiplexing (DWDM) technology. This allows multiple optical signals to be transmitted simultaneously over a single optical fiber, greatly increasing the capacity and efficiency of the network. By leveraging DWDM, service providers can maximize their existing infrastructure without the need for extensive new fiber installation.

Another significant characteristic of the Z-PLEX-10-24-DOC-SC is its scalability. The system is designed to grow with the telecommunication needs of operators, supporting various service types, including voice, video, and data, without sacrificing performance or quality. This flexibility ensures that as users' demands evolve, the Z-PLEX-10-24-DOC-SC can adapt to meet these changing requirements.

The unit also incorporates advanced management features, supported by Zhone's innovative software tools. These tools facilitate network monitoring, configuration, and maintenance, allowing operators to optimize their operations and provide better service to their end-users. This end-to-end management capability is essential in today’s fast-paced digital landscape, where customer satisfaction is paramount.

In summary, the Zhone Technologies Z-PLEX-10-24-DOC-SC is a powerful optical networking solution that combines advanced technology with scalability and efficiency. It empowers service providers to deliver high-quality broadband services while optimizing their resources. With its DWDM support, compact design, and robust management tools, the Z-PLEX-10-24-DOC-SC stands out as a reliable choice for modern telecommunications infrastructure.