Zhone Technologies Z-PLEX-10-24-DOC-SC manual Introduction Product specifications, AMI, B8ZS

Page 15

Introduction

Product specifications

T1 interface

Physical

Two RJ48

 

Frame format

D4, ESF, SLC96 (TR-08)

 

Line code

AMI, B8ZS

 

Line equalization

0 to 133 ft., 134 to 266 ft., 267 to 533 ft., 534 to 655 ft.

 

CSU line buildOut (LBO)

0 dB, -7.5 dB, -15.0 dB, -22.5 dB, automatic receive sensitivity

 

DSX line length

0.6 dB for 0 - 250 ft, 1.8 dB for 251 - 500 ft, 3.0 dB for 501 - 700 ft

 

Clocking

Internal Stratum 4, line

 

FDL

Per ANSI T1.403, AT&T Pub TR62411

 

Input level

+3.0dB to -36dB

 

TR08 support

Universal voice grade (UVG), single-party (SP) signaling

 

Diagnostics

QRSS, line loopback, CSU LB detection, performance statistics over FDL, bantam

 

 

jacks for in-session T1 monitoring

FXS interface

Physical

One 50-pin female amphenol, up to 24 ports

 

FXS supervision mode

FXS, FXS-DN, FXS-DN-Wink, TR-08

 

FXS signaling

Loop Start, Ground Start, Loop Start with forward Disconnect, Ground Start

 

 

Immediate, Ground Start Automatic, Universal Voice Grade, Universal Voice Grade

 

 

Automatic, Single-Party

 

TLP

Increments of 1dB, -3dB to +9dB on transmit; -9dB to +3dB on receive

 

Impedance

600 Ohm

 

Ringing voltage

50 VRMS, on hook transmission for Caller ID support

 

Loop length

At least 800 Ohms external resistance including set

 

Others

CLASS features (distinctive ringing, Caller ID)

 

 

compatibility with V.34 and V90 modem standards

FX0 interface

Physical

One 50-pin female amphenol, up to 8 ports

 

FXO supervision mode

FXO, dial pulse termination

 

FXO signaling

Loop Start, Ground Start, Loop Start with forced Disconnect, Ground Start with

 

 

forced Disconnect, DPT

 

 

Increments of 1dB, -3dB to +9dB on transmit; -9dB to +3dB on receive

 

TLP

600 Ohm

 

Loop length

At least 800 Ohms external resistance including set

 

Others

CLASS features (distinctive ringing, Caller ID)

 

 

compatibility with V.34 and V90 modem standards

Data interface

Physical

One V.35 port (female DB25)

 

Frame format

Transparent HDLC (NRZ, NRZI)

 

Data Rate

Nx56K, Nx64K (N=1-24)

 

Gender

DCE

 

Hardware signaling

RTS/CTS with on, off, auto

 

 

RTS/CTS programmable delay from 0 to 100msec

 

Diagnostics

Local and line loopbacks.

10Base-T interface

Physical

One RJ45

 

Frame format

Ethernet IEEE802.3

 

Interface speed

10Mbps

 

Protocols

IP, SNMP and telnet

 

Diagnostics

SNMP and telnet management, alarm traps

Serial port

Physical

One female DB9

 

Electrical

RS232

 

Interface speed

9600, 19,200, 38,400 bps. The default is 9600

 

Protocols

Asynchronous

Diagnostics

 

Extensive power-up self test

 

 

LED Indicators

 

 

QRSS Test Pattern on T1; 2047 Test Pattern on Data ports

 

 

Loopbacks for FXO/FXS, T1 and Data ports

 

 

CSU Loopback detection

 

 

Performance statistics over FDL

 

 

Bantam jacks for in-session T1 monitoring and line testing

Alarm contacts

 

The alarm connector is OPEN during NORMAL operating conditions

 

 

Alarm connector CLOSES for duration of major alarms only.

 

 

The contacts close both alarm connector and 25th pair of Amphenol connector.

Zhone Technologies / 1-5

Image 15
Contents Plex User’s Guide Trademarks FCC Part 68 Regulatory Information Regulatory InformationIndustrie Canada Requirements Country-Specific Regulatory Compliance InformationPage Page Contents Chapter Diagnostics Chapter Configuring the ZPlexAppendix a Alphabetical Reference \ Zhone Technologies Introduction Product overview Product overviewTR-08 FeaturesFeatures Introduction BenefitsManaging the Z-Plex SnmpIntroduction Managing the Z-Plex Tftp Product specificationsProduct specifications Introduction 2 CLIAMI, B8ZS Introduction Product specificationsProduct specifications Introduction Installing the Z-Plex Product description Product descriptionBack panel Kit of parts Unpacking the productFront panel Packing materialsImportant Safety Instructions Installing the productInstalling the product Installing the Z-Plex Rack mounting Installing the Z-Plex Rack mountingLocating the product on a desktop Installing the Z-Plex Locating the product on a desktopWall mounting Connector type Electrical Installation Connector typeBackpanel connectors Data port connector pinouts Data port connector pinouts Electrical InstallationDCE DB25 data port female connector 1 FXO/FXS connectors Electrical Installation Data port connector pinoutsPair female amphenol connector T1 connector pinouts Power requirements2 RJ48 connector Power requirements Electrical InstallationAC power installation AlarmPower installation Electrical Installation AlarmGrounding requirements Grounding requirements Electrical InstallationElectrical Installation Cabling CablingRecommended cables Cabling Electrical Installation Configuring the Z-Plex Using the command line interface Using the command line interfaceQuick start system configuration Configuring the Z-Plex Quick start system configurationConfiguring the Z-Plex Quick start system configuration Setting the date Configuring a management interfaceLogging in and out of the system Configuring the IP over FDL management channel Configuring the local management channelConfiguring the DS0 management channel Configuring the Ethernet management channelConfiguring Snmp Configuring system contact informationConfiguring Snmp Configuring the Z-Plex Configuring the Z-Plex Configuring T1 interfaces Configuring T1 interfacesConfiguring FXS ports Configuring a T1 drop and insert interfaceConfiguring the Z-Plex Configuring FXO ports Configuring FXO portsConfiguring the V.35 data port Configuring the Z-Plex Configuring the V.35 data portConfiguring the Z-Plex Adding and deleting routes Adding and deleting routesAdding and deleting network routes Example routing configuration Adding and deleting routes Configuring the Z-PlexAdding and deleting host routes Displaying routes Example routing configurationDisplaying host routes Route Display ValuesDisplaying flash information System maintenance commandsRebooting the system Configuring the Z-Plex System maintenance commandsDisplaying timeslot usage Displaying list of alarmsDisplaying and clearing list of history alarms System maintenance commands Configuring the Z-PlexTftp downloading Activating code in bank18 \ Zhone Technologies T1 loopbacks Diagnostics T1 loopbacksT1 loopbacks T1 loopbacks DiagnosticsActivating a BER test for individual time slots BER testingDiagnostics BER testing Activating a BER test for an entire T1 lineData port loopbacks Data port loopbacks DiagnosticsDiagnostics Testing FXO and FXS ports Testing FXO and FXS portsFXO and FXS ports loopback Testing FXO and FXS ports DiagnosticsConfiguring FXS loopbacks Configuring FXO loopbacksSetting or viewing the transmit Abcd signaling bits Using test mode on the FXO and FXS portsLED indicators Alarm LEDDiagnostics LED indicators WAN LEDs Power LEDLED indicators Diagnostics Ethernet LEDAlphabetical Reference Parameter reference Configuration groupsTable A-1. Configuration groups in the Z-Plex Parameter referenceParameter reference Alphabetical Reference Fxotst Alphabetic reference Allfarint AllcurAllfarcur AllfartotBert BESCLK CTS CtsdelayClksrc CodeDS0 CURDSR ErrinsFDL Fdlip FrameHdlc INT IpfdlIphdl Linelen LofcLoop FXO Loop FXS LoopbackLoopback T1 Maskhdl Mode FXOMask MaskfdlMode FXS Nchan PatternRate Rlsd RngbkRtlp FXO Rtlp FXS RxAB FXORxAB FXS State SchanSES SlipState FXO State FXSState T1 Sysname SyscontactSysdescr SyslocationTest FXS TOTTrcntl FXO Trcntrl FXS Trnkc FXOTrnkc FXS Trstat FXO Trstat FXSTS data port TS FXS TS FXOTtlp FXS TsbertoffTsberton Ttlp FXOTxAB FXO TxAB FXSType FXO Type FXS WAN FXO TypeUAS WANCommand reference Reboot Error messagesAlphabetical Reference Error messages QueryhalarmError messages Alphabetical Reference Alphabetical Reference CLI reference Basic control commandsTable A-4. Basic control commands CLI referenceCLI reference Alphabetical Reference Movement and search commandsInsert and change commands Table A-5. Movement and search commandsTable A-6. Insert and change commands Table A-8. Put and undo commands Delete commandsPut and undo commands Table A-7. Delete commandsUndo last command 38 \ Zhone Technologies Index LED 194-4 Index-4 / Zhone Technologies WAN LED

Z-PLEX-10-24-DOC-SC specifications

Zhone Technologies is a leading provider of innovative telecommunications and data networking solutions, and the Z-PLEX-10-24-DOC-SC is one of their advanced products designed to meet the demands of modern networking environments. This versatile optical networking solution is ideal for service providers looking to deliver high-speed broadband services to residential and business customers.

The Z-PLEX-10-24-DOC-SC provides an impressive 24-port capability, making it a robust choice for deployment in various settings, from small community networks to larger metropolitan areas. Its compact design allows for easy integration into existing systems, minimizing the need for extensive reconfiguration or additional space. The system is geared towards enabling efficient fiber deployment and helps operators enhance their service offerings while reducing operational expenses.

One of the main features of the Z-PLEX-10-24-DOC-SC is its support for Dense Wavelength Division Multiplexing (DWDM) technology. This allows multiple optical signals to be transmitted simultaneously over a single optical fiber, greatly increasing the capacity and efficiency of the network. By leveraging DWDM, service providers can maximize their existing infrastructure without the need for extensive new fiber installation.

Another significant characteristic of the Z-PLEX-10-24-DOC-SC is its scalability. The system is designed to grow with the telecommunication needs of operators, supporting various service types, including voice, video, and data, without sacrificing performance or quality. This flexibility ensures that as users' demands evolve, the Z-PLEX-10-24-DOC-SC can adapt to meet these changing requirements.

The unit also incorporates advanced management features, supported by Zhone's innovative software tools. These tools facilitate network monitoring, configuration, and maintenance, allowing operators to optimize their operations and provide better service to their end-users. This end-to-end management capability is essential in today’s fast-paced digital landscape, where customer satisfaction is paramount.

In summary, the Zhone Technologies Z-PLEX-10-24-DOC-SC is a powerful optical networking solution that combines advanced technology with scalability and efficiency. It empowers service providers to deliver high-quality broadband services while optimizing their resources. With its DWDM support, compact design, and robust management tools, the Z-PLEX-10-24-DOC-SC stands out as a reliable choice for modern telecommunications infrastructure.