Zhone Technologies Z-PLEX-10-24-DOC-SC manual CLI reference, Basic control commands

Page 91

Alphabetical Reference

CLI reference

A.4 CLI reference

The basic CLI commands are divided into the following categories:

Basic control commands

Movement and searching commands

Insert and change commands

Delete commands

Put and undo commands

The following sections describe these commands.

A.4.1 Basic control commands

Table A-4describes the basic commands to edit, delete, and enter commands into the system.

 

Table A-4. Basic control commands

 

 

Command

Description

 

 

h [size]

Display the shell history if no argument; otherwise set history

 

buffer to the specified size.

 

 

ESC

Switch the line editing mode from regular input mode.

 

 

ENTER

Enter line and leave edit mode.

 

 

CTRL + H

Delete a character (backspace).

 

 

CTRL + U

Delete and entire line (in edit mode).

 

 

CTRL + L

Redraw a line (in edit mode).

 

 

CTRL + D

Complete a symbol name (in edit mode) or end shell session (in

 

input mode).

 

 

CTRL + S

Suspend output.

 

 

CTRL + Q

Resume output.

 

 

Zhone Technologies / A-33

Image 91
Contents Plex User’s Guide Trademarks FCC Part 68 Regulatory Information Regulatory InformationIndustrie Canada Requirements Country-Specific Regulatory Compliance InformationPage Page Contents Chapter Diagnostics Chapter Configuring the ZPlexAppendix a Alphabetical Reference \ Zhone Technologies Introduction Product overview Product overviewTR-08 FeaturesFeatures Introduction BenefitsSnmp Managing the Z-PlexIntroduction Managing the Z-Plex Tftp Product specificationsProduct specifications Introduction 2 CLIAMI, B8ZS Introduction Product specificationsProduct specifications Introduction Product description Installing the Z-Plex Product descriptionBack panel Kit of parts Unpacking the productFront panel Packing materialsImportant Safety Instructions Installing the productInstalling the product Installing the Z-Plex Rack mounting Installing the Z-Plex Rack mountingLocating the product on a desktop Locating the product on a desktop Installing the Z-PlexWall mounting Electrical Installation Connector type Connector typeBackpanel connectors Data port connector pinouts Electrical Installation Data port connector pinoutsDCE DB25 data port female connector Electrical Installation Data port connector pinouts 1 FXO/FXS connectorsPair female amphenol connector T1 connector pinouts Power requirements2 RJ48 connector Power requirements Electrical InstallationAC power installation AlarmPower installation Electrical Installation AlarmGrounding requirements Grounding requirements Electrical InstallationCabling Electrical Installation CablingRecommended cables Cabling Electrical Installation Configuring the Z-Plex Using the command line interface Using the command line interfaceQuick start system configuration Configuring the Z-Plex Quick start system configurationConfiguring the Z-Plex Quick start system configuration Configuring a management interface Setting the dateLogging in and out of the system Configuring the IP over FDL management channel Configuring the local management channelConfiguring the DS0 management channel Configuring the Ethernet management channelConfiguring system contact information Configuring SnmpConfiguring Snmp Configuring the Z-Plex Configuring the Z-Plex Configuring T1 interfaces Configuring T1 interfacesConfiguring FXS ports Configuring a T1 drop and insert interfaceConfiguring the Z-Plex Configuring FXO ports Configuring FXO portsConfiguring the V.35 data port Configuring the Z-Plex Configuring the V.35 data portAdding and deleting routes Configuring the Z-Plex Adding and deleting routesAdding and deleting network routes Adding and deleting routes Configuring the Z-Plex Example routing configurationAdding and deleting host routes Displaying routes Example routing configurationDisplaying host routes Route Display ValuesDisplaying flash information System maintenance commandsRebooting the system Configuring the Z-Plex System maintenance commandsDisplaying timeslot usage Displaying list of alarmsDisplaying and clearing list of history alarms System maintenance commands Configuring the Z-PlexTftp downloading Activating code in bank18 \ Zhone Technologies T1 loopbacks Diagnostics T1 loopbacksT1 loopbacks T1 loopbacks DiagnosticsActivating a BER test for individual time slots BER testingDiagnostics BER testing Activating a BER test for an entire T1 lineData port loopbacks Data port loopbacks DiagnosticsDiagnostics Testing FXO and FXS ports Testing FXO and FXS portsFXO and FXS ports loopback Testing FXO and FXS ports DiagnosticsConfiguring FXS loopbacks Configuring FXO loopbacksSetting or viewing the transmit Abcd signaling bits Using test mode on the FXO and FXS portsAlarm LED LED indicatorsDiagnostics LED indicators WAN LEDs Power LEDLED indicators Diagnostics Ethernet LEDAlphabetical Reference Parameter reference Configuration groupsTable A-1. Configuration groups in the Z-Plex Parameter referenceParameter reference Alphabetical Reference Fxotst Alphabetic reference Allfarint AllcurAllfarcur AllfartotBES BertCLK CTS CtsdelayClksrc CodeDS0 CURErrins DSRFDL Frame FdlipHdlc Ipfdl INTIphdl Lofc LinelenLoop FXO Loopback Loop FXSLoopback T1 Maskhdl Mode FXOMask MaskfdlMode FXS Pattern NchanRate Rngbk RlsdRtlp FXO RxAB FXO Rtlp FXSRxAB FXS State SchanSES SlipState FXS State FXOState T1 Sysname SyscontactSysdescr SyslocationTOT Test FXSTrcntl FXO Trnkc FXO Trcntrl FXSTrnkc FXS Trstat FXS Trstat FXOTS data port TS FXS TS FXOTtlp FXS TsbertoffTsberton Ttlp FXOTxAB FXS TxAB FXOType FXO Type FXS WAN FXO TypeUAS WANCommand reference Reboot Error messagesAlphabetical Reference Error messages QueryhalarmError messages Alphabetical Reference Alphabetical Reference CLI reference Basic control commandsTable A-4. Basic control commands CLI referenceCLI reference Alphabetical Reference Movement and search commandsTable A-5. Movement and search commands Insert and change commandsTable A-6. Insert and change commands Table A-8. Put and undo commands Delete commandsPut and undo commands Table A-7. Delete commandsUndo last command 38 \ Zhone Technologies Index LED 194-4 Index-4 / Zhone Technologies WAN LED

Z-PLEX-10-24-DOC-SC specifications

Zhone Technologies is a leading provider of innovative telecommunications and data networking solutions, and the Z-PLEX-10-24-DOC-SC is one of their advanced products designed to meet the demands of modern networking environments. This versatile optical networking solution is ideal for service providers looking to deliver high-speed broadband services to residential and business customers.

The Z-PLEX-10-24-DOC-SC provides an impressive 24-port capability, making it a robust choice for deployment in various settings, from small community networks to larger metropolitan areas. Its compact design allows for easy integration into existing systems, minimizing the need for extensive reconfiguration or additional space. The system is geared towards enabling efficient fiber deployment and helps operators enhance their service offerings while reducing operational expenses.

One of the main features of the Z-PLEX-10-24-DOC-SC is its support for Dense Wavelength Division Multiplexing (DWDM) technology. This allows multiple optical signals to be transmitted simultaneously over a single optical fiber, greatly increasing the capacity and efficiency of the network. By leveraging DWDM, service providers can maximize their existing infrastructure without the need for extensive new fiber installation.

Another significant characteristic of the Z-PLEX-10-24-DOC-SC is its scalability. The system is designed to grow with the telecommunication needs of operators, supporting various service types, including voice, video, and data, without sacrificing performance or quality. This flexibility ensures that as users' demands evolve, the Z-PLEX-10-24-DOC-SC can adapt to meet these changing requirements.

The unit also incorporates advanced management features, supported by Zhone's innovative software tools. These tools facilitate network monitoring, configuration, and maintenance, allowing operators to optimize their operations and provide better service to their end-users. This end-to-end management capability is essential in today’s fast-paced digital landscape, where customer satisfaction is paramount.

In summary, the Zhone Technologies Z-PLEX-10-24-DOC-SC is a powerful optical networking solution that combines advanced technology with scalability and efficiency. It empowers service providers to deliver high-quality broadband services while optimizing their resources. With its DWDM support, compact design, and robust management tools, the Z-PLEX-10-24-DOC-SC stands out as a reliable choice for modern telecommunications infrastructure.