Zhone Technologies Z-PLEX-10-24-DOC-SC Alphabetical Reference Error messages, Queryhalarm

Page 89

Alphabetical Reference

Error messages

QUERYHALARM

Displays a list of history alarms.

REBOOT

Reboots the system.

TFTPDLD

This command initiates a TFTP download. It prompts for the IP address of the server, the code bank to download the image to, and the filename of the software image.

A.3 Error messages

Table A-3describes the error messages.

 

Table A-3. Error messages

 

 

Message

Explanation

 

 

FDL mgmt not supported

Tried to activate FDL on WAN 2. Only WAN 1 supports IP over

on this wan

FDL.

 

 

Invalid instance number.

Invalid index for a static route.

Valid range is 1-16

 

 

 

Invalid Loopback

Loopback activated while another loop back (either local or remote)

 

is active.

 

 

Invalid MTU size valid

Invalid MTU size.

range is 128-1500

 

 

 

Invalid parameter value

Invalid parameter value in SET command.

 

 

Invalid time slot valid

Tried to assign invalid TS.

range is 1-24

 

 

 

Invalid Wan Number

Tried to enter an invalid WAN number.

 

 

IP broadcast address

User tried to assign broadcast IP address. The Z-Plex unit does not

cannot be used

support broadcast IP addresses.

 

 

Zhone Technologies / A-31

Image 89
Contents Plex User’s Guide Trademarks FCC Part 68 Regulatory Information Regulatory InformationIndustrie Canada Requirements Country-Specific Regulatory Compliance InformationPage Page Contents Chapter Diagnostics Chapter Configuring the ZPlexAppendix a Alphabetical Reference \ Zhone Technologies Introduction Product overview Product overviewFeatures Introduction FeaturesBenefits TR-08Introduction Managing the Z-Plex Managing the Z-PlexSnmp Product specifications Introduction Product specifications2 CLI TftpAMI, B8ZS Introduction Product specificationsProduct specifications Introduction Back panel Installing the Z-Plex Product descriptionProduct description Front panel Unpacking the productPacking materials Kit of partsImportant Safety Instructions Installing the productInstalling the product Installing the Z-Plex Rack mounting Installing the Z-Plex Rack mountingWall mounting Locating the product on a desktop Installing the Z-PlexLocating the product on a desktop Backpanel connectors Connector typeElectrical Installation Connector type DCE DB25 data port female connector Data port connector pinoutsData port connector pinouts Electrical Installation Pair female amphenol connector 1 FXO/FXS connectorsElectrical Installation Data port connector pinouts 2 RJ48 connector Power requirementsPower requirements Electrical Installation T1 connector pinoutsPower installation AlarmElectrical Installation Alarm AC power installationGrounding requirements Grounding requirements Electrical InstallationRecommended cables Electrical Installation CablingCabling Cabling Electrical Installation Configuring the Z-Plex Using the command line interface Using the command line interfaceQuick start system configuration Configuring the Z-Plex Quick start system configurationConfiguring the Z-Plex Quick start system configuration Logging in and out of the system Setting the dateConfiguring a management interface Configuring the DS0 management channel Configuring the local management channelConfiguring the Ethernet management channel Configuring the IP over FDL management channelConfiguring Snmp Configuring the Z-Plex Configuring SnmpConfiguring system contact information Configuring the Z-Plex Configuring T1 interfaces Configuring T1 interfacesConfiguring FXS ports Configuring a T1 drop and insert interfaceConfiguring the Z-Plex Configuring FXO ports Configuring FXO portsConfiguring the V.35 data port Configuring the Z-Plex Configuring the V.35 data portAdding and deleting network routes Configuring the Z-Plex Adding and deleting routesAdding and deleting routes Adding and deleting host routes Example routing configurationAdding and deleting routes Configuring the Z-Plex Displaying routes Example routing configurationDisplaying host routes Route Display ValuesRebooting the system System maintenance commandsConfiguring the Z-Plex System maintenance commands Displaying flash informationDisplaying and clearing list of history alarms Displaying list of alarmsSystem maintenance commands Configuring the Z-Plex Displaying timeslot usageTftp downloading Activating code in bank18 \ Zhone Technologies T1 loopbacks Diagnostics T1 loopbacksT1 loopbacks T1 loopbacks DiagnosticsDiagnostics BER testing BER testingActivating a BER test for an entire T1 line Activating a BER test for individual time slotsData port loopbacks Data port loopbacks DiagnosticsDiagnostics Testing FXO and FXS ports Testing FXO and FXS portsFXO and FXS ports loopback Testing FXO and FXS ports DiagnosticsConfiguring FXS loopbacks Configuring FXO loopbacksSetting or viewing the transmit Abcd signaling bits Using test mode on the FXO and FXS portsDiagnostics LED indicators LED indicatorsAlarm LED LED indicators Diagnostics Power LEDEthernet LED WAN LEDsTable A-1. Configuration groups in the Z-Plex Configuration groupsParameter reference Alphabetical Reference Parameter referenceParameter reference Alphabetical Reference Fxotst Alphabetic reference Allfarcur AllcurAllfartot AllfarintCLK BertBES Clksrc CtsdelayCode CTSDS0 CURFDL DSRErrins Hdlc FdlipFrame Iphdl INTIpfdl Loop FXO LinelenLofc Loopback T1 Loop FXSLoopback Mask Mode FXOMaskfdl MaskhdlMode FXS Rate NchanPattern Rtlp FXO RlsdRngbk RxAB FXS Rtlp FXSRxAB FXO SES SchanSlip StateState T1 State FXOState FXS Sysdescr SyscontactSyslocation SysnameTrcntl FXO Test FXSTOT Trnkc FXS Trcntrl FXSTrnkc FXO TS data port Trstat FXOTrstat FXS TS FXS TS FXOTsberton TsbertoffTtlp FXO Ttlp FXSType FXO TxAB FXOTxAB FXS Type FXS UAS TypeWAN WAN FXOCommand reference Alphabetical Reference Error messages Error messagesQueryhalarm RebootError messages Alphabetical Reference Table A-4. Basic control commands Basic control commandsCLI reference Alphabetical Reference CLI referenceCLI reference Alphabetical Reference Movement and search commandsTable A-6. Insert and change commands Insert and change commandsTable A-5. Movement and search commands Put and undo commands Delete commandsTable A-7. Delete commands Table A-8. Put and undo commandsUndo last command 38 \ Zhone Technologies Index LED 194-4 Index-4 / Zhone Technologies WAN LED

Z-PLEX-10-24-DOC-SC specifications

Zhone Technologies is a leading provider of innovative telecommunications and data networking solutions, and the Z-PLEX-10-24-DOC-SC is one of their advanced products designed to meet the demands of modern networking environments. This versatile optical networking solution is ideal for service providers looking to deliver high-speed broadband services to residential and business customers.

The Z-PLEX-10-24-DOC-SC provides an impressive 24-port capability, making it a robust choice for deployment in various settings, from small community networks to larger metropolitan areas. Its compact design allows for easy integration into existing systems, minimizing the need for extensive reconfiguration or additional space. The system is geared towards enabling efficient fiber deployment and helps operators enhance their service offerings while reducing operational expenses.

One of the main features of the Z-PLEX-10-24-DOC-SC is its support for Dense Wavelength Division Multiplexing (DWDM) technology. This allows multiple optical signals to be transmitted simultaneously over a single optical fiber, greatly increasing the capacity and efficiency of the network. By leveraging DWDM, service providers can maximize their existing infrastructure without the need for extensive new fiber installation.

Another significant characteristic of the Z-PLEX-10-24-DOC-SC is its scalability. The system is designed to grow with the telecommunication needs of operators, supporting various service types, including voice, video, and data, without sacrificing performance or quality. This flexibility ensures that as users' demands evolve, the Z-PLEX-10-24-DOC-SC can adapt to meet these changing requirements.

The unit also incorporates advanced management features, supported by Zhone's innovative software tools. These tools facilitate network monitoring, configuration, and maintenance, allowing operators to optimize their operations and provide better service to their end-users. This end-to-end management capability is essential in today’s fast-paced digital landscape, where customer satisfaction is paramount.

In summary, the Zhone Technologies Z-PLEX-10-24-DOC-SC is a powerful optical networking solution that combines advanced technology with scalability and efficiency. It empowers service providers to deliver high-quality broadband services while optimizing their resources. With its DWDM support, compact design, and robust management tools, the Z-PLEX-10-24-DOC-SC stands out as a reliable choice for modern telecommunications infrastructure.