Zhone Technologies Z-PLEX-10-24-DOC-SC manual Ts Fxo, Ts Fxs

Page 83

Alphabetical Reference

Parameter reference

Figure 5-4illustrates how to determine the TS value if you want to use the first four time slots for drop and insert (0000000f).

Figure 5-4.Time slot assignment for drop and insert

Time slots

31 30 29

28

27 26 25

24

23 22 21 20

19 18 17

16

15 14 13

12

11 10 9

8

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time slot

0 0 0

0

0 0 0

0

0 0 0 0

0 0 0

0

0 0 0

0

0 0 0

0

0

0

0

0

1

1

1

1

assignment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hex value

0

 

0

 

0

0

 

0

 

0

 

 

 

0

 

 

 

f

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configuration group: T1CFG

Syntax: (GET/SET) FXSCFG:TS:n:(00000000-ffffffff)

TS (FXO)

Specify the time slots used for FXO service. By default, time slot 1 is mapped to FXO port 2, time slot 2 is mapped to FXO port 2, and so on.

Notes

Each time slot assignment must be unique, even if the time slots are on different WAN lines.

Configuration group: FXOCFG

Syntax: (GET/SET) FXOCFG:TS:n:(1-24)

See also: WAN (FXO)

TS (FXS)

Specify the time slots used for FXS service. By default, time slot 1 is mapped to FXS port 2, time slot 2 is mapped to FXS port 2, and so on.

Notes

Each time slot assignment must be unique, even if the time slots are on different WAN lines.

Configuration group: FXSCFG

Zhone Technologies / A-25

Image 83
Contents Plex User’s Guide Trademarks FCC Part 68 Regulatory Information Regulatory InformationIndustrie Canada Requirements Country-Specific Regulatory Compliance InformationPage Page Contents Chapter Diagnostics Chapter Configuring the ZPlexAppendix a Alphabetical Reference \ Zhone Technologies Introduction Product overview Product overviewTR-08 FeaturesFeatures Introduction BenefitsIntroduction Managing the Z-Plex Managing the Z-PlexSnmp Tftp Product specificationsProduct specifications Introduction 2 CLIAMI, B8ZS Introduction Product specificationsProduct specifications Introduction Back panel Installing the Z-Plex Product descriptionProduct description Kit of parts Unpacking the productFront panel Packing materialsImportant Safety Instructions Installing the productInstalling the product Installing the Z-Plex Rack mounting Installing the Z-Plex Rack mountingWall mounting Locating the product on a desktop Installing the Z-PlexLocating the product on a desktop Backpanel connectors Connector typeElectrical Installation Connector type DCE DB25 data port female connector Data port connector pinoutsData port connector pinouts Electrical Installation Pair female amphenol connector 1 FXO/FXS connectorsElectrical Installation Data port connector pinouts T1 connector pinouts Power requirements2 RJ48 connector Power requirements Electrical InstallationAC power installation AlarmPower installation Electrical Installation AlarmGrounding requirements Grounding requirements Electrical InstallationRecommended cables Electrical Installation CablingCabling Cabling Electrical Installation Configuring the Z-Plex Using the command line interface Using the command line interfaceQuick start system configuration Configuring the Z-Plex Quick start system configurationConfiguring the Z-Plex Quick start system configuration Logging in and out of the system Setting the dateConfiguring a management interface Configuring the IP over FDL management channel Configuring the local management channelConfiguring the DS0 management channel Configuring the Ethernet management channelConfiguring Snmp Configuring the Z-Plex Configuring SnmpConfiguring system contact information Configuring the Z-Plex Configuring T1 interfaces Configuring T1 interfacesConfiguring FXS ports Configuring a T1 drop and insert interfaceConfiguring the Z-Plex Configuring FXO ports Configuring FXO portsConfiguring the V.35 data port Configuring the Z-Plex Configuring the V.35 data portAdding and deleting network routes Configuring the Z-Plex Adding and deleting routesAdding and deleting routes Adding and deleting host routes Example routing configurationAdding and deleting routes Configuring the Z-Plex Displaying routes Example routing configurationDisplaying host routes Route Display ValuesDisplaying flash information System maintenance commandsRebooting the system Configuring the Z-Plex System maintenance commandsDisplaying timeslot usage Displaying list of alarmsDisplaying and clearing list of history alarms System maintenance commands Configuring the Z-PlexTftp downloading Activating code in bank18 \ Zhone Technologies T1 loopbacks Diagnostics T1 loopbacksT1 loopbacks T1 loopbacks DiagnosticsActivating a BER test for individual time slots BER testingDiagnostics BER testing Activating a BER test for an entire T1 lineData port loopbacks Data port loopbacks DiagnosticsDiagnostics Testing FXO and FXS ports Testing FXO and FXS portsFXO and FXS ports loopback Testing FXO and FXS ports DiagnosticsConfiguring FXS loopbacks Configuring FXO loopbacksSetting or viewing the transmit Abcd signaling bits Using test mode on the FXO and FXS portsDiagnostics LED indicators LED indicatorsAlarm LED WAN LEDs Power LEDLED indicators Diagnostics Ethernet LEDAlphabetical Reference Parameter reference Configuration groupsTable A-1. Configuration groups in the Z-Plex Parameter referenceParameter reference Alphabetical Reference Fxotst Alphabetic reference Allfarint AllcurAllfarcur AllfartotCLK BertBES CTS CtsdelayClksrc CodeDS0 CURFDL DSRErrins Hdlc FdlipFrame Iphdl INTIpfdl Loop FXO LinelenLofc Loopback T1 Loop FXSLoopback Maskhdl Mode FXOMask MaskfdlMode FXS Rate NchanPattern Rtlp FXO RlsdRngbk RxAB FXS Rtlp FXSRxAB FXO State SchanSES SlipState T1 State FXOState FXS Sysname SyscontactSysdescr SyslocationTrcntl FXO Test FXSTOT Trnkc FXS Trcntrl FXSTrnkc FXO TS data port Trstat FXOTrstat FXS TS FXS TS FXOTtlp FXS TsbertoffTsberton Ttlp FXOType FXO TxAB FXOTxAB FXS Type FXS WAN FXO TypeUAS WANCommand reference Reboot Error messagesAlphabetical Reference Error messages QueryhalarmError messages Alphabetical Reference Alphabetical Reference CLI reference Basic control commandsTable A-4. Basic control commands CLI referenceCLI reference Alphabetical Reference Movement and search commandsTable A-6. Insert and change commands Insert and change commandsTable A-5. Movement and search commands Table A-8. Put and undo commands Delete commandsPut and undo commands Table A-7. Delete commandsUndo last command 38 \ Zhone Technologies Index LED 194-4 Index-4 / Zhone Technologies WAN LED

Z-PLEX-10-24-DOC-SC specifications

Zhone Technologies is a leading provider of innovative telecommunications and data networking solutions, and the Z-PLEX-10-24-DOC-SC is one of their advanced products designed to meet the demands of modern networking environments. This versatile optical networking solution is ideal for service providers looking to deliver high-speed broadband services to residential and business customers.

The Z-PLEX-10-24-DOC-SC provides an impressive 24-port capability, making it a robust choice for deployment in various settings, from small community networks to larger metropolitan areas. Its compact design allows for easy integration into existing systems, minimizing the need for extensive reconfiguration or additional space. The system is geared towards enabling efficient fiber deployment and helps operators enhance their service offerings while reducing operational expenses.

One of the main features of the Z-PLEX-10-24-DOC-SC is its support for Dense Wavelength Division Multiplexing (DWDM) technology. This allows multiple optical signals to be transmitted simultaneously over a single optical fiber, greatly increasing the capacity and efficiency of the network. By leveraging DWDM, service providers can maximize their existing infrastructure without the need for extensive new fiber installation.

Another significant characteristic of the Z-PLEX-10-24-DOC-SC is its scalability. The system is designed to grow with the telecommunication needs of operators, supporting various service types, including voice, video, and data, without sacrificing performance or quality. This flexibility ensures that as users' demands evolve, the Z-PLEX-10-24-DOC-SC can adapt to meet these changing requirements.

The unit also incorporates advanced management features, supported by Zhone's innovative software tools. These tools facilitate network monitoring, configuration, and maintenance, allowing operators to optimize their operations and provide better service to their end-users. This end-to-end management capability is essential in today’s fast-paced digital landscape, where customer satisfaction is paramount.

In summary, the Zhone Technologies Z-PLEX-10-24-DOC-SC is a powerful optical networking solution that combines advanced technology with scalability and efficiency. It empowers service providers to deliver high-quality broadband services while optimizing their resources. With its DWDM support, compact design, and robust management tools, the Z-PLEX-10-24-DOC-SC stands out as a reliable choice for modern telecommunications infrastructure.