Zhone Technologies Z-PLEX-10-24-DOC-SC BER testing, Activating a BER test for an entire T1 line

Page 51

Diagnostics

BER testing

5.2BER testing

The bit error rate (BER) test sends a data pattern and measures the bit error rate on the selected interface. The Z-Plex supports BER tests on entire T1 lines or on individual time slots. The BER test supports the following BER test patterns:

Quasi-random signal source (QRSS)

ALT (10101010)

2047

During a BER test, all connections between either the data ports or the FXS/FXO ports and the T1 interface are broken and a test pattern is transmitted onto the T1 interface. During the test, the WAN LED blinks green.

5.2.1Activating a BER test for an entire T1 line

To configure a BER test on an entire T1 line, enter the following command:

user> SET T1CFG:BERT:x:(QRSS/ALT/2047)

where x is the number of the T1 interface to loopback. To end the BER test, enter the following command:

user> SET T1CFG:BERT:x:OFF

While the BER test is active, you can insert random BIT errors into the test data stream using the following command:

user> SET T1BE:ERRINS:x:BIT

5.2.2Activating a BER test for individual time slots

To configure a BER test on single T1 timeslot:

1.Specify the BER test pattern for the test:

user> SET T1CFG:BERT:x:(QRSS/ALT/2047)

where x is the number of the T1 interface to apply the pattern to.

2.Activate the BER test:

user> SET T1CFG:TSBERTON:x:(1-24)

3.To de-activate the BER test:

Zhone Technologies / 5-3

Image 51
Contents Plex User’s Guide Trademarks FCC Part 68 Regulatory Information Regulatory InformationIndustrie Canada Requirements Country-Specific Regulatory Compliance InformationPage Page Contents Chapter Diagnostics Chapter Configuring the ZPlexAppendix a Alphabetical Reference \ Zhone Technologies Introduction Product overview Product overviewTR-08 FeaturesFeatures Introduction BenefitsManaging the Z-Plex SnmpIntroduction Managing the Z-Plex Tftp Product specificationsProduct specifications Introduction 2 CLIAMI, B8ZS Introduction Product specificationsProduct specifications Introduction Installing the Z-Plex Product description Product descriptionBack panel Kit of parts Unpacking the productFront panel Packing materialsImportant Safety Instructions Installing the productInstalling the product Installing the Z-Plex Rack mounting Installing the Z-Plex Rack mountingLocating the product on a desktop Installing the Z-Plex Locating the product on a desktopWall mounting Connector type Electrical Installation Connector typeBackpanel connectors Data port connector pinouts Data port connector pinouts Electrical InstallationDCE DB25 data port female connector 1 FXO/FXS connectors Electrical Installation Data port connector pinoutsPair female amphenol connector T1 connector pinouts Power requirements2 RJ48 connector Power requirements Electrical InstallationAC power installation AlarmPower installation Electrical Installation AlarmGrounding requirements Grounding requirements Electrical InstallationElectrical Installation Cabling CablingRecommended cables Cabling Electrical Installation Configuring the Z-Plex Using the command line interface Using the command line interfaceQuick start system configuration Configuring the Z-Plex Quick start system configurationConfiguring the Z-Plex Quick start system configuration Setting the date Configuring a management interfaceLogging in and out of the system Configuring the IP over FDL management channel Configuring the local management channelConfiguring the DS0 management channel Configuring the Ethernet management channelConfiguring Snmp Configuring system contact informationConfiguring Snmp Configuring the Z-Plex Configuring the Z-Plex Configuring T1 interfaces Configuring T1 interfacesConfiguring FXS ports Configuring a T1 drop and insert interfaceConfiguring the Z-Plex Configuring FXO ports Configuring FXO portsConfiguring the V.35 data port Configuring the Z-Plex Configuring the V.35 data portConfiguring the Z-Plex Adding and deleting routes Adding and deleting routesAdding and deleting network routes Example routing configuration Adding and deleting routes Configuring the Z-PlexAdding and deleting host routes Displaying routes Example routing configurationDisplaying host routes Route Display ValuesDisplaying flash information System maintenance commandsRebooting the system Configuring the Z-Plex System maintenance commandsDisplaying timeslot usage Displaying list of alarmsDisplaying and clearing list of history alarms System maintenance commands Configuring the Z-PlexTftp downloading Activating code in bank18 \ Zhone Technologies T1 loopbacks Diagnostics T1 loopbacksT1 loopbacks T1 loopbacks DiagnosticsActivating a BER test for individual time slots BER testingDiagnostics BER testing Activating a BER test for an entire T1 lineData port loopbacks Data port loopbacks DiagnosticsDiagnostics Testing FXO and FXS ports Testing FXO and FXS portsFXO and FXS ports loopback Testing FXO and FXS ports DiagnosticsConfiguring FXS loopbacks Configuring FXO loopbacksSetting or viewing the transmit Abcd signaling bits Using test mode on the FXO and FXS portsLED indicators Alarm LEDDiagnostics LED indicators WAN LEDs Power LEDLED indicators Diagnostics Ethernet LEDAlphabetical Reference Parameter reference Configuration groupsTable A-1. Configuration groups in the Z-Plex Parameter referenceParameter reference Alphabetical Reference Fxotst Alphabetic reference Allfarint AllcurAllfarcur AllfartotBert BESCLK CTS CtsdelayClksrc CodeDS0 CURDSR ErrinsFDL Fdlip FrameHdlc INT IpfdlIphdl Linelen LofcLoop FXO Loop FXS LoopbackLoopback T1 Maskhdl Mode FXOMask MaskfdlMode FXS Nchan PatternRate Rlsd RngbkRtlp FXO Rtlp FXS RxAB FXORxAB FXS State SchanSES SlipState FXO State FXSState T1 Sysname SyscontactSysdescr SyslocationTest FXS TOTTrcntl FXO Trcntrl FXS Trnkc FXOTrnkc FXS Trstat FXO Trstat FXSTS data port TS FXS TS FXOTtlp FXS TsbertoffTsberton Ttlp FXOTxAB FXO TxAB FXSType FXO Type FXS WAN FXO TypeUAS WANCommand reference Reboot Error messagesAlphabetical Reference Error messages QueryhalarmError messages Alphabetical Reference Alphabetical Reference CLI reference Basic control commandsTable A-4. Basic control commands CLI referenceCLI reference Alphabetical Reference Movement and search commandsInsert and change commands Table A-5. Movement and search commandsTable A-6. Insert and change commands Table A-8. Put and undo commands Delete commandsPut and undo commands Table A-7. Delete commandsUndo last command 38 \ Zhone Technologies Index LED 194-4 Index-4 / Zhone Technologies WAN LED

Z-PLEX-10-24-DOC-SC specifications

Zhone Technologies is a leading provider of innovative telecommunications and data networking solutions, and the Z-PLEX-10-24-DOC-SC is one of their advanced products designed to meet the demands of modern networking environments. This versatile optical networking solution is ideal for service providers looking to deliver high-speed broadband services to residential and business customers.

The Z-PLEX-10-24-DOC-SC provides an impressive 24-port capability, making it a robust choice for deployment in various settings, from small community networks to larger metropolitan areas. Its compact design allows for easy integration into existing systems, minimizing the need for extensive reconfiguration or additional space. The system is geared towards enabling efficient fiber deployment and helps operators enhance their service offerings while reducing operational expenses.

One of the main features of the Z-PLEX-10-24-DOC-SC is its support for Dense Wavelength Division Multiplexing (DWDM) technology. This allows multiple optical signals to be transmitted simultaneously over a single optical fiber, greatly increasing the capacity and efficiency of the network. By leveraging DWDM, service providers can maximize their existing infrastructure without the need for extensive new fiber installation.

Another significant characteristic of the Z-PLEX-10-24-DOC-SC is its scalability. The system is designed to grow with the telecommunication needs of operators, supporting various service types, including voice, video, and data, without sacrificing performance or quality. This flexibility ensures that as users' demands evolve, the Z-PLEX-10-24-DOC-SC can adapt to meet these changing requirements.

The unit also incorporates advanced management features, supported by Zhone's innovative software tools. These tools facilitate network monitoring, configuration, and maintenance, allowing operators to optimize their operations and provide better service to their end-users. This end-to-end management capability is essential in today’s fast-paced digital landscape, where customer satisfaction is paramount.

In summary, the Zhone Technologies Z-PLEX-10-24-DOC-SC is a powerful optical networking solution that combines advanced technology with scalability and efficiency. It empowers service providers to deliver high-quality broadband services while optimizing their resources. With its DWDM support, compact design, and robust management tools, the Z-PLEX-10-24-DOC-SC stands out as a reliable choice for modern telecommunications infrastructure.