Frame Relay Statistics

The Frame Relay Management Statistics dialog box can be a useful tool for troubleshooting MultiFRAD installations and monitoring the performance of active links, and determining if the MultiFRAD is talking to the provider’s switch.

The Polling Details section lists the various management frames sent and received. For every Status Enquiry Sent, a Status Response should be received from the network. Likewise, for every Full Status Enquiry Sent, there should be one Full Status Response received. The two status enquiry types are used by the FRAD to verify that the frame relay network is operational, and to determine which DLCIs are active. Under default settings a status enquiry is sent every ten seconds, and every sixth enquiry will be a Full Status Enquiry.

The Enquiries Sent and the Responses Received should increment together, and should be equal under normal circumstances. Any gap between them reflects a breakdown in communication with the provider’s switch, and will be reflected as Missed Status Responses.

The Status Errors section lists the number of errors that have occurred. A Missed Status Response means that the frame relay network did not respond to a status enquiry from the MultiFRAD before the next status enquiry was sent (by default there are 10 seconds between status enquiries).

A Sequence Error means that the sequence numbers in a received status response do not match what the MultiFRAD expected based on its Status Enquiry. Basically, the Status Enquiry has two numbers (or counts), and one should be incremented by the network and then both numbers should be returned to the FRAD in the Status Response. Sequence Number Errors also reflect missing packets between the MultiFRAD and the switch, but should not be a cause for alarm unless they are incrementing rapidly and steadily.

The Link Details section records the number of times the frame relay link between the MultiFRAD and the network has gone up (become active) or gone down (become inactive). The Link Details provide a more general picture of the status of communication between the MultiFRAD and the frame relay network.

43

Image 43
Contents Models FR3060/3100 User Guide User Guide Contents Appendices Introduction and Description Preview of this Guide IntroductionRouter Management Composite Link Front Panel DescriptionVoice/Fax Channels 1 Monitor XMT/RCV Connector Power ConnectorFrame Ground GND Connector Internal Composite Link T1 DSU ConnectorVoice/Fax Channels 1 8 Connectors Channels 3 10 ConnectorsEthernet Port Technical SpecificationsCommand Port Channel ConnectorsInstallation Unpacking your MultiFRAD Safety WarningsPC or Terminal Units Cabling your MultiFRADMultiFRAD 3000-Series User Guide Software Loading and Configuration Loading your Software Software Loading and Configuration MultiFRAD 3000-Series User Guide Software Loading and Configuration MultiFRAD 3000-Series User Guide Software Loading and Configuration MultiFRAD 3000-Series User Guide Software Loading and Configuration MultiFRAD 3000-Series User Guide MultiFRAD Software Before You Begin Setup Menu IP Setup MultiFRAD Software IPX Setup MultiFRAD Software Spanning Tree Setup Statistics IP Statistics IPX Port Statistics STP Spanning Tree Port Statistics Snmp Statistics WAN Statistics PPP Statistics Data Port Statistics Frame Relay Statistics MultiFRAD 3000-Series User Guide WAN Port Setup Point to Point Setup Frame Relay Setup MultiFRAD 3000-Series User Guide MultiFRAD Software MultiFRAD 3000-Series User Guide Frame Relay Network Data Port Configuration Remote Configuration Modem-Based Remote Configuration Procedure Remote Configuration MultiFRAD 3000-Series User Guide Remote Configuration MultiFRAD 3000-Series User Guide Router Management MultiFRAD Telnet Server Menu Remote User Database MultiFRAD ConfigurationWEB Browser Management Router Management MultiFRAD 3000-Series User Guide Warranty, Service and Tech Support On-line Warranty Registration Limited WarrantyRecording MultiFRAD Information Tech SupportContacting Tech Support via E-mail Multi-Tech BBS ServiceTo log on to the Multi-Tech BBS If you know the file name To Download a fileAbout CompuServe About the Multi-Tech Fax-Back ServiceAbout the Internet Appendices LAN Cables Appendix a Cabling Diagrams Command Port CableRS232C/V.24 * Link Cable Trunk CableCommand Port Remote Configuration CableAppendix B Regulatory Information Figure B-1. OSI Protocol Stack Appendix C Network OverviewPacket Internet Protocol IP Network AddressIP Addressing MultiFRAD 3000-Series User Guide Glossary MultiFRAD 3000-Series User Guide Glossary MultiFRAD 3000-Series User Guide Glossary MultiFRAD 3000-Series User Guide Glossary MultiFRAD 3000-Series User Guide Glossary MultiFRAD 3000-Series User Guide Glossary Subscriber Loop See Local loop Glossary MultiFRAD 3000-Series User Guide Index LEDs Index Telnet