Multitech 3100, FR3060 manual Frame Relay Setup

Page 47

Chapter 4 - MultiFRAD Software

Frame Relay Setup

The Frame Relay dialog box displays the CIR Measurement Interval in milliseconds, the Management Type and details of that management type, and the number of DLCI’s that are active. The MultiFRAD can detect DLCIs and the Management Type when you are connected to an active frame relay service. So it is important that if you change any frame relay parameters, that the new parameters agree with the way your frame relay service is provisioned.

In the Frame Relay Setup dialog box, you can change the Management Type by choosing one of the three options and then the detail parameters for that option are displayed to the right of the Management Type. For example, in the above dialog box, Annex D is the chosen management type with the Full Status Enquiry Interval [N391] set to 6 down thru Polling Verification Timer [T392] set to 15.

Usually, you will have no need to change the management type because the MultiFRAD will automatically detect the network’s management type at power-up, or when the network becomes active. This auto-detection feature takes about 1 to 2 minutes to detect the management type and get a list of the DLCI’s.

Occasionally the Management Type parameters can be changed to correct a problem. In these cases making the following changes could alleviate the problem:

1.Change the Link Integrity Verification Timer. This feature sets how often the MultiFRAD verifies that the link is good. Changing the setting from the default value of 10 seconds, to a lower value, i.e.,

5seconds, will increase the frequency of those verifications.

2.Change the Full Status Enquiry Interval to affect how often DCLI Status is updated. This

parameter defines how often the MultiFRAD will send a request for DLCI status information along with the Link Integrity Verification request. The default value is to include such a request every sixth time the link integrity is checked. A value less than every sixth request will allow faster detection of active/inactive DLCIs, but will also produce a slight increase in management overhead.

3.Change the Monitored Events Count and the Error Threshold to affect the MultiFRAD’s sensitivity to errors on the link. Every management frame received by the MultiFRAD is considered an event, and if the link integrity sequence numbers are wrong, for example, it is considered an “errored” event. With the default settings, if Error Threshold is 3 and Monitored Events Count is 4, and 3 out of 4 events are “errored”, then the link is considered to be bad, and the FRAD stops sending on all DLCIs and restarts the initial procedures to activate the link.

4.Change the CIR Measurement Interval to change the time frame in which the FRAD calculates throughput for each DLCI. By default, every 1000 milliseconds (1 second), the MultiFRAD calculates how much information has been sent on each DLCI, and depending on the congestion management option for a DLCI the MultiFRAD may stop sending on that DLCI because it has exceeded its CIR or CIR+Be rating. By changing the CIR Measurement interval, the throughput calculations can be made more or less often.

Note: performance could be compromised if the MultiFRAD is set to calculate throughput too often.

47

Image 47
Contents Models FR3060/3100 User Guide User Guide Contents Appendices Introduction and Description Preview of this Guide IntroductionRouter Management Composite Link Front Panel DescriptionVoice/Fax Channels 1 Monitor XMT/RCV Connector Power ConnectorFrame Ground GND Connector Internal Composite Link T1 DSU ConnectorVoice/Fax Channels 1 8 Connectors Channels 3 10 ConnectorsEthernet Port Technical SpecificationsCommand Port Channel ConnectorsInstallation Unpacking your MultiFRAD Safety WarningsPC or Terminal Units Cabling your MultiFRADMultiFRAD 3000-Series User Guide Software Loading and Configuration Loading your Software Software Loading and Configuration MultiFRAD 3000-Series User Guide Software Loading and Configuration MultiFRAD 3000-Series User Guide Software Loading and Configuration MultiFRAD 3000-Series User Guide Software Loading and Configuration MultiFRAD 3000-Series User Guide MultiFRAD Software Before You Begin Setup Menu IP Setup MultiFRAD Software IPX Setup MultiFRAD Software Spanning Tree Setup Statistics IP Statistics IPX Port Statistics STP Spanning Tree Port Statistics Snmp Statistics WAN Statistics PPP Statistics Data Port Statistics Frame Relay Statistics MultiFRAD 3000-Series User Guide WAN Port Setup Point to Point Setup Frame Relay Setup MultiFRAD 3000-Series User Guide MultiFRAD Software MultiFRAD 3000-Series User Guide Frame Relay Network Data Port Configuration Remote Configuration Modem-Based Remote Configuration Procedure Remote Configuration MultiFRAD 3000-Series User Guide Remote Configuration MultiFRAD 3000-Series User Guide Router Management MultiFRAD Telnet Server Menu Remote User Database MultiFRAD ConfigurationWEB Browser Management Router Management MultiFRAD 3000-Series User Guide Warranty, Service and Tech Support On-line Warranty Registration Limited WarrantyContacting Tech Support via E-mail Tech SupportRecording MultiFRAD Information To log on to the Multi-Tech BBS ServiceMulti-Tech BBS If you know the file name To Download a fileAbout the Internet About the Multi-Tech Fax-Back ServiceAbout CompuServe Appendices LAN Cables Appendix a Cabling Diagrams Command Port CableRS232C/V.24 * Link Cable Trunk CableCommand Port Remote Configuration CableAppendix B Regulatory Information Figure B-1. OSI Protocol Stack Appendix C Network OverviewPacket Internet Protocol IP Network AddressIP Addressing MultiFRAD 3000-Series User Guide Glossary MultiFRAD 3000-Series User Guide Glossary MultiFRAD 3000-Series User Guide Glossary MultiFRAD 3000-Series User Guide Glossary MultiFRAD 3000-Series User Guide Glossary MultiFRAD 3000-Series User Guide Glossary Subscriber Loop See Local loop Glossary MultiFRAD 3000-Series User Guide Index LEDs Index Telnet