Multitech MT5634ZBA-USB manual Basic Procedure, Changing the Setup Password

Page 38

MT5634ZBA-USB User Guide

Introduction

Remote configuration is a network management tool that allows you to configure modems anywhere in your network from one location. With password-protected remote configuration, you can issue AT commands to a remote MT5634ZBA-USB modem for maintenance or troubleshooting as if you were on-site.

Basic Procedure

The following steps are valid regardless of whether the connection is established by the local or the remote Multi-Tech modem.

1.Establish a data connection with a remote MT5634ZBA-USB modem.

2.Send three remote configuration escape characters followed by AT and the setup password, and press ENTER. Example: %%%ATMTSMODEM<CR>. You have four tries to enter the correct password before being disconnected. If the password is correct, the remote modem responds with

OK

3.You can now send AT commands to configure the remote modem.

4.When you have finished configuring the remote modem, save the new configuration by typing AT&W0<CR>, then type ATO<CR> to exit remote configuration. You can then break the connection in the normal way.

CAUTION: If you hang up while you are in remote configuration mode, it may lock up the remote modem.

Setup

Multi-Tech modems are shipped with a default setup password (MTSMODEM). Because anyone who has an owner’s manual knows the default setup password, for security you should change the password and possibly also the remote configuration escape character.

Changing the Setup Password

1.Open a data communications program such as HyperTerminal.

2.In the terminal window, type AT#SMTSMODEM (or AT#Syyyyyy if you have replaced the MTSMODEM password with yyyyyy) and press ENTER. The modem responds with OK if the setup password is correct, and ERROR if it is wrong.

3.To change the password, type AT#S=yyyyyy, where yyyyyy stands for the password, and press ENTER. The password can include any keyboard character, and must be one to eight characters long. The modem responds with OK.

4.The new password is saved automatically. You can now either enter more AT commands or exit the data communications program. The next time you remotely configure the modem you must use the new setup password.

Note: You can only change the setup password locally; you cannot do it remotely. Also, passwords are case sensitive. The next time you enter the password, it must be in the same case as you set it up.

38

Image 38
Contents User Guide Record of Revisions TrademarksContents Index Introduction and Description Universal Serial Bus USB IntroductionProduct Description MT5634ZBA-USB User GuideWhat Is in Your Modem Package? Introduction and DescriptionMT5634ZBA-USB User Guide Quick Start We supply Safety WarningsWhat You Will Need You supplyAssemble the Modem Quick StartInstall the Software Phone Connection Connect the Modem to Your SystemLine Connection USB ConnectionSelect the Modem Test Your ModemFeatures Data FeaturesWhat Can You Do with Your Modem? Computer FaxRequired Equipment Telephone LineConnecting to a Telephone Set Phone Connecting to the Computer USBConnecting to the Telephone Line Line ConnectionsFront Panel Front panelMT5634ZBA-USB User Guide AT Commands, S-Registers and Result Codes AT Commands AT Command Summary Monitor Speaker Volume Command DS=n Dial Stored Telephone NumberEcho Command Mode Characters Echo Online Data CharactersResult Codes Enable/Disable Monitor Speaker ModeReturn Online to Data Mode Command Sr=n Set Register ValueCommand Yn Long Space Disconnect MT5634ZBA-USB User Guide Command Vn Result Code FormatCommand Xn Result Code Selection Modem ResetCommunications Mode Load Factory SettingsCommand &Gn V.22bis Guard Tone Control Asynchronous Communications ModeCommand &Wn Store Current Configuration MT5634ZBA-USB User Guide Command &Tn V.54 Test CommandsDisplay Current Settings Select Stored Configuration for Hard ResetData Buffer Control Error Correction Mode SelectionModem Port Flow Control Break ControlCommand %DCnAT Command Control Inactivity TimerCommand %Cn Data Compression Control Protocol Result CodeCommand #S=x Store Setup Password Command %En Fallback and Fall Forward ControlEnter Setup Password Command%%%ATCRRemote Configuration Escape SequenceRegisters Rates K56flex Rates S37S38 S48 S42S43 S89Result Codes Terse Verbose DescriptionMT5634ZBA-USB User Guide Remote Configuration Changing the Setup Password Basic ProcedureSetup Remote Configuration Changing the Remote Escape CharacterMT5634ZBA-USB User Guide Troubleshooting None of the Indicators Light Modem Does Not Respond to CommandsTroubleshooting Modem Dials But Cannot ConnectModem Doesn’t Work with Caller ID Modem Cannot Connect When AnsweringModem Disconnects While Online Fax and Data Software Can’t Run at the Same TimeAppendixes Appendix a Regulatory Compliance FCC Regulations for Telephone Line InterconnectionClass B Statement Industry CanadaCanadian Limitations Notice FAX Branding StatementNew Zealand Telecom Warning Notice European DirectivesInternational Modem Restrictions Appendix B Technical Specifications ITU-T ConnectorsCarrier Frequencies ITU-T V.32bis/V.32 Carrier FrequenciesDimensions DiagnosticsIndicators WeightAppendix C Loopback Tests IntroductionFigure C-1. Local analog loopback test Test Procedure Local Analog Loopback Test V.54 LoopRemote Digital Loopback Test V.54 Loop Appendix C Loopback TestsFigure C-3. Local digital loopback test Test Procedure Local Digital Loopback Test V.54 LoopOnline Warranty Registration Appendix D Warranty, Service, and Technical SupportLimited Warranty ServiceTo Log on to the Multi-Tech BBS Technical SupportMulti-Tech BBS To Download a FileAbout the Multi-Tech Fax-Back Service About the InternetIndex Index MT5634ZBA-USB User Guide