Multitech MT5634ZBA-USB Monitor Speaker Mode, Modulation Handshake, Return Online to Data Mode

Page 25

 

Chapter 4 - AT Commands, S-Registers and Result Codes

 

 

Command: Mn

Monitor Speaker Mode

Values:

n = 0, 1, 2, or 3

Default:

1

Description:M0

Speaker always off.

M1

Speaker on until carrier signal detected.

M2

Speaker always on when modem is off-hook.

M3

Speaker on until carrier is detected, except while dialing.

Command: Nn

Modulation Handshake

Values:

n = 0 or 1

Default:

1

Description:N0

Modem performs handshake only at communication standard specified by S37 and the B

 

command.

N1

Modem begins handshake at communication standard specified by S37 and the B com-

 

mand. During handshake, fallback to a lower speed can occur.

Command: On

Return Online to Data Mode

Values:

0, 1, 3

Default:

None

Description:O0

Exit online command mode and return to data mode (see +++AT<CR> escape sequence ).

O1

Issue a retrain and return to online data mode.

O3

Issue a rate renegotiation and return to data mode.

Command: P

Pulse Dialing

Values:

P, T

Default:

T

Description:

Configures the modem for pulse (non-touch-tone) dialing. Dialed digits are pulsed until a T

 

command or dial modifier is received.

Command: Qn

Result Codes Enable/Disable

Values:

n = 0 or 1

Default:

0

Description:Q0

Enable result codes.

Q1

Disable result codes.

Q2

Returns an OK for backward compatibility with some software.

Command: Sr=n Set Register Value

Values:

r = S-register number; n varies

Default:

None

Description:

Set value of register Sr to value of n, where n is entered in decimal format. E.g., S0=1.

Command: Sr?

Read Register Value

Values:

r = S-register number

Default:

None

Description:

Read value of register Sr and display it in 3-digit decimal form. E.g., S2? gives the re-

 

sponse 043.

Command: T

Tone Dialing

Values:

P, T

Default:

T

Description:

Configures the modem for DTMF (touch-tone) dialing. Dialed digits are tone dialed until a P

 

command or dial modifier is received.

25

Image 25
Contents User Guide Trademarks Record of RevisionsContents Index Introduction and Description Product Description IntroductionUniversal Serial Bus USB MT5634ZBA-USB User GuideIntroduction and Description What Is in Your Modem Package?MT5634ZBA-USB User Guide Quick Start What You Will Need Safety WarningsWe supply You supplyQuick Start Assemble the ModemInstall the Software Line Connection Connect the Modem to Your SystemPhone Connection USB ConnectionTest Your Modem Select the ModemFeatures What Can You Do with Your Modem? FeaturesData Required Equipment FaxComputer Telephone LineConnecting to the Telephone Line Line Connecting to the Computer USBConnecting to a Telephone Set Phone ConnectionsFront panel Front PanelMT5634ZBA-USB User Guide AT Commands, S-Registers and Result Codes AT Commands AT Command Summary Echo Command Mode Characters Command DS=n Dial Stored Telephone NumberMonitor Speaker Volume Echo Online Data CharactersReturn Online to Data Mode Monitor Speaker ModeResult Codes Enable/Disable Command Sr=n Set Register ValueCommand Xn Result Code Selection MT5634ZBA-USB User Guide Command Vn Result Code FormatCommand Yn Long Space Disconnect Modem ResetCommand &Gn V.22bis Guard Tone Control Load Factory SettingsCommunications Mode Asynchronous Communications ModeDisplay Current Settings MT5634ZBA-USB User Guide Command &Tn V.54 Test CommandsCommand &Wn Store Current Configuration Select Stored Configuration for Hard ResetModem Port Flow Control Error Correction Mode SelectionData Buffer Control Break ControlCommand %Cn Data Compression Control Inactivity TimerCommand %DCnAT Command Control Protocol Result CodeEnter Setup Password Command %En Fallback and Fall Forward ControlCommand #S=x Store Setup Password Command%%%ATCRRemote Configuration Escape SequenceRegisters S38 S37Rates K56flex Rates S43 S42S48 S89Terse Verbose Description Result CodesMT5634ZBA-USB User Guide Remote Configuration Setup Basic ProcedureChanging the Setup Password Changing the Remote Escape Character Remote ConfigurationMT5634ZBA-USB User Guide Troubleshooting Modem Does Not Respond to Commands None of the Indicators LightModem Dials But Cannot Connect TroubleshootingModem Disconnects While Online Modem Cannot Connect When AnsweringModem Doesn’t Work with Caller ID Fax and Data Software Can’t Run at the Same TimeAppendixes FCC Regulations for Telephone Line Interconnection Appendix a Regulatory ComplianceIndustry Canada Class B StatementFAX Branding Statement Canadian Limitations NoticeInternational Modem Restrictions European DirectivesNew Zealand Telecom Warning Notice Appendix B Technical Specifications Carrier Frequencies ConnectorsITU-T ITU-T V.32bis/V.32 Carrier FrequenciesIndicators DiagnosticsDimensions WeightIntroduction Appendix C Loopback TestsLocal Analog Loopback Test V.54 Loop Figure C-1. Local analog loopback test Test ProcedureAppendix C Loopback Tests Remote Digital Loopback Test V.54 LoopLocal Digital Loopback Test V.54 Loop Figure C-3. Local digital loopback test Test ProcedureLimited Warranty Appendix D Warranty, Service, and Technical SupportOnline Warranty Registration ServiceMulti-Tech BBS Technical SupportTo Log on to the Multi-Tech BBS To Download a FileAbout the Internet About the Multi-Tech Fax-Back ServiceIndex Index MT5634ZBA-USB User Guide