| Chapter 4 - AT Commands, |
|
|
Command: &Fn | Load Factory Settings |
Values: | n = 0 |
Default: | None |
Description:&F0 | Load factory settings as active configuration. |
Note: See also the Z command. | |
Command: &Gn V.22bis Guard Tone Control | |
Values: | n = 0, 1, or 2 |
Default: | 0 |
Description:&G0 | Disable guard tone. |
&G1 | Set guard tone to 550 Hz. |
&G2 | Set guard tone to 1800 Hz. |
Note: The &G command is not used in North America.
Command: &Jn | Auxiliary Relay Control |
Values: | n = 0 |
Default: | 0 |
Description:&J0 | The auxiliary relay is never closed. |
&J1 | Not |
Command: &Kn | Flow Control Selection |
Values: | n = 0, 3, or 4 |
Defaults: | 3 |
Description:&K0 | Disable flow control. |
&K3 | Enable CTS/RTS hardware flow control. |
&K4 | Enable XON/XOFF software flow control. |
Command: &Mn | Communications Mode |
Values: | n = 0 |
Defaults: | 0 |
Description:&M0 | Asynchronous mode. |
&M1 | Not |
Command: &Qn | Asynchronous Communications Mode |
Values: | n = 0, 5, 6, 8, or 9 |
Default: | 5 |
Description:&Q0 | Asynchronous with data buffering. Same as \N0. |
&Q5 | Error control with data buffering. Same as \N3. |
&Q6 | Asynchronous with data buffering. Same as \N0. |
&Q8 | MNP error control mode. If MNP error control is not established, the modem falls back ac- |
| cording to the setting in S36. |
&Q9 | V.42 or MNP error control mode. If neither error control is established, the modem falls |
| back according to the setting in S36. |
Command: &Sn | Data Set Ready (DSR) Control |
Values: | n = 0 or 1 |
Default: | 0 |
Description:&S0 | Force DSR always high (on). |
&S1 | Let DSR go high only during a connection. |
27