Advantech ADAM-4550 user manual Read Configuration, Write Identification

Page 22

4.2 Read Configuration

Description Requests to read the current baud rate and address from the module.

Syntax $AA2(cr)

AA:module address ( 2 hexa- decimal characters )

Response !AATTCCFFPP(cr) if the com- mand is valid (refer to “Set New Configuration” in Command Set)

?AA(cr) if an invalid command is entered

Example Command : $0A2(cr)

Response:

!0A40AA2103(cr)

4.3 Write Identification

Description Requests to assign identification data to the module at address

AA.The identification character lengths can range from 0 to 16 bytes including carriage-return.

Syntax $AA6(identification characters)(cr)

Response !AA(cr) if the command is valid

?AA(cr) if an invalid command is entered

Example Command: $0A6ADAM4550 Unit#1(cr)

Response: !0A(cr)

22

ADAM-4550 User's Manual

Image 22
Contents ADAM-4550 Contents FCC Identification FCC WarningIntroduction FeaturesBuilt-in Intelligence Page Factory Default Settings InstallationBasic Configuration Power SupplyRS-485 Communication Wiring Software ConfigurationConfiguring ADAM-4550 Basic Connection Diagram Pin Assignment Uploading a New Version of Firmware Using the Diagnostics Functions Antenna Installation Using ADAM-4550 ADAM-4550-S RS-232 115.2ADAM-4550-01 Test Sample ADAM-4550 Command Set SyntaxConfiguration Mode Commands Data Pass Mode Commands Command Descriptions Set New ConfigurationExample Command Read Configuration Write IdentificationRead Identification Set Delimiter CharacterRead Delimiter Character Set Data GateRemain at Open Gate/Write to Flash Example Read Data Gate Status DescriptionResponse Read Firmware VersionRead Module Name UploadingSend Data to Remote Get Error Rate Statistics Data Pass modeAppendix a External Antenna Options DBi Omni-Directional AntennaDBi Grid Parabolic Reflector Directional Antenna Appendix B External Antenna Wiring Diagram