Advantech ADAM-4550 user manual Send Data to Remote

Page 28

Example

Command :

$0AL(cr)

 

Response

: !0A(cr)

 

command : 0A 80 12 34 56

 

.....................

length 2688

 

bytes followed by data 12h 34h

4.12. Send Data to Remote

Description

Send the DATA to RS-485 de-

 

vice through the remote module

 

at address AA

This command only works in Data Pass mode. The user can use the “Set Data Gate” com- mand to open the data gate of the module at AA so that you

can send the data to module AA without {AA.

Syntax {AA(Data string)(cr)

{— one of the eight optional de- limiters which is configured into the module

Example Command : {0C123456abcdABCD(cr)

The command sends data ‘123456abcdABCD(cr)’ through the local ADAM4550 and the re- mote ADAM-4550 module at ad- dress 0Ch to a connected RS- 485 device.

28

ADAM-4550 User's Manual

Image 28
Contents ADAM-4550 Contents FCC Identification FCC WarningIntroduction FeaturesBuilt-in Intelligence Page Installation Basic ConfigurationFactory Default Settings Power SupplyRS-485 Communication Wiring Software ConfigurationConfiguring ADAM-4550 Basic Connection Diagram Pin Assignment Uploading a New Version of Firmware Using the Diagnostics Functions Antenna Installation Using ADAM-4550 ADAM-4550-S RS-232 115.2ADAM-4550-01 Test Sample ADAM-4550 Command Set SyntaxConfiguration Mode Commands Data Pass Mode Commands Command Descriptions Set New ConfigurationExample Command Read Configuration Write IdentificationRead Identification Set Delimiter CharacterRead Delimiter Character Set Data GateRemain at Open Gate/Write to Flash Read Data Gate Status Description ResponseExample Read Firmware VersionRead Module Name UploadingSend Data to Remote Get Error Rate Statistics Data Pass modeAppendix a External Antenna Options DBi Omni-Directional AntennaDBi Grid Parabolic Reflector Directional Antenna Appendix B External Antenna Wiring Diagram