RAD Data comm ASM-60 operation manual Package Contents, Installation and Setup

Page 26

Chapter 2 Installation and Setup

ASM-60Installation and Operation Manual

 

 

 

 

 

 

 

 

 

2.2 Package Contents

The ASM-60 package includes the following items:

One ASM-60 unit

Last Mile Access and Intelligent Modems CD

AC power cord

RM-28 rack installation kit (if ordered).

2.3 Installation and Setup

The ASM-60 standalone unit is designed for desktop installation and is delivered as a fully assembled unit. No provisions are made for bolting the unit to a tabletop.

To install ASM-60:

1.Determine the required configuration of ASM-60, in accordance with your application.

2.Set the DIP switches of the Ethernet interface module accordingly.

3.Connect the line (see Connecting the Line below).

4.Connect the DTE (see Connecting the DTE below).

5.Connect power to the unit (see Connecting the Power below).

Performing the Internal Settings

ASM-60 with HSSI interface does not contain any jumpers or switches for user settings. For instructions on configuring ASM-60 units with an Ethernet interface module, refer to the respective appendix of this manual.

Access to the inside of the equipment is permitted only to the authorized and qualified personnel.

To avoid accidental electric shock, always disconnect the interface cables and Warning the power cord before removing the unit from its casing.

Line voltages are present inside ASM-60 when it is connected to power and/or the lines. Moreover, under certain fault conditions, dangerous voltages may appear on the lines connected to the unit.

Any adjustment, maintenance and repair of the opened instrument under voltage must be avoided as much as possible and, when inevitable, should be carried out only by a skilled technician who is aware of the hazard involved. Capacitors inside the unit may still be charged even after the unit has been disconnected from its source of power.

Caution ASM-60 contains components sensitive to electrostatic discharge (ESD). To prevent ESD damage, avoid touching the internal components. Before moving the jumper, touch the ASM-60 frame.

2-2

Installation and Setup

Image 26
Contents ASM-60 Page ASM-60 International Headquarters RAD Data Communications IncLimited Warranty General Safety Instructions Please observe the following precautionsConnection of DC Mains General Safety PracticesConnection of AC Mains Ports Safety Status Connection of Data and Telecommunications CablesElectromagnetic Compatibility EMC Canadian Emission Requirements Page Product Name SafetyManufacturers Name Manufacturers Address Supplementary InformationPage Connecting the Interfaces Installing ASM-60Setting the Internal Switches Connecting the PowerNormal Indications Configuring ASM-60Operating ASM-60 Selecting the Data RateContents Diagnostics List of Figures Table of Contents Versions Chapter IntroductionOverview ApplicationFeatures Physical Description D View of ASM-60ASM-60 Block Diagram Functional DescriptionData Rate Technical SpecificationsRange Interface 24/RS-232 TypeFuse 250A, slow-blow AC Voltage 100 to 240 VAC ±10%, 50 to 60 Hz, 6W ProtectionTransformers to the transmit and receive lines Chapter Installation and Setup Site Requirements and PrerequisitesPackage Contents Installation and SetupClosing the ASM-60 Case Connecting the LineOpening the ASM-60 Case To connect the Hssi interface Connecting the DTEHssi Interface Connector Pinout To connect the AC power Installation and Setup Chapter Operation Front Panel IndicatorsLED Indicators Name FunctionNormal Operation ASM-60 Indicator StatusTurning On ASM-60 Turning Off ASM-60Preparing for the Control Session Control Port Interface CharacteristicsChapter Management from a Terminal Preparing TerminalTo initiate a control session Navigating the Management MenusInitiating a Control Session To choose an optionStarting the Control Session Terminal Management MenusTo display the Configuration menu Main MenuTo access the Display menu Displaying the ASM-60 System InformationDisplaying the ASM-60 Status To display the ASM-60 statusResetting ASM-60 To reset ASM-60Resetting ASM-60 Power-Up Self-Test Chapter DiagnosticsError Detection AlarmsTo access the log file Working with the Log FileTo display the Vdsl diagnostics Displaying the Vdsl Performance DiagnosticsASM-60 Alarms Number Terminal Message Description SeverityAfter the ASM-60 power-up ASM-60 Performance Monitoring ParametersTo run the LEDs test Running the Diagnostic TestsRunning the LEDs Test Running the Diagnostic Tests IR-ETH Connector Options Appendix a IR-ETH Interface ModuleProtocol Appendix a IR-ETH Interface ModuleTable A-2. DIP Switch Settings Installation and OperationDIP Switch Settings Section Name Description Default Number SettingTable A-3. IR-ETH Bridge LED Indicators LED IndicatorsConnecting to LAN Description Location Color NameIntroduction IR-ETH/QH ConnectorAppendix B IR-ETH/QH Interface Module Protocol Point-to-point Data Rate Kbps to 45 Mbps Table B-1 RJ-45 Connector PinoutPin Signal Function Table B-3. IR-ETH/QH LED Indicators Setting the DIP SwitchTable B-2. DIP Switch Settings Section Name Description Possible Settings Factory SettingConnecting the LAN Appendix C IR-IP Interface Module OverviewStandard Conforms to Ieee 802.3/Ethernet Data Rate Mbps Delay FrameConnector 10BaseT UTP Shielded RJ-45 ProtocolsTable C-1. IR-IP LEDs Functions IR-IP DIP SwitchIR-IP LEDs Table C-3 RJ-45 PinoutIntroduction Accessing the IR-IP Management SubsystemIR-IP Management Subsystem, General Outline of Preliminary Configuration Performing Preliminary ConfigurationDefault IP Communication Parameters To perform the preliminary configuration procedureAssigning the Router LAN Interface Address Connecting the Telnet HostPreliminary Telnet Host Configuration IP Learning MechanismAssigning a LAN IP Address to a New IR-IP To view and edit the ARP table contentsTo configure the IP router LAN address No ping replies from IR-IP Changing the LAN IP Address of a Configured IR-IPWhat to Do If IP learning process is not successfulStarting a Management Utility General Operating ProceduresIR-IP Management Utility Menu Structure of Management Utility Quick Setup MenuTo access the Quick Setup menu LAN IP Mask Default GatewayLAN IP Address WAN IP AddressProtocol Read Protocol from DIP SwitchesOperation with Default Gateway ParametersTelnet Inactivity Timeout Management Access MenuTelnet Password To access the Management Access menuTo access the Device Identification menu Advanced Setup MenuTo access the Advanced Setup menu Device Identification MenuInterface Parameters Menu WAN Protocol Parameters Frame Relay Protocol Menu Aging TimeoutMaintenance Protocol WAN ThrottleHeader and Control Field Compression Authentication ProtocolWAN Protocol Parameters PPP Protocol Menu Protocol Field CompressionSecurity Host/Guest Password To SendPassword To Accept User Name To SendMulticast Forwarding To access the Multicast IP menuMulticast IP Menu Device Control Menu To access the Static Groups menuTo access the Device Control menu Static GroupsServer IP Address Total TimeoutNew Software Download Menu File NameReset Device View Error Log ScreenResets Menu Reset LANView Menu Configuration and ConnectionReset WAN ARP Tables To access the ARP Tables screenTo access the Multicast Groups Table screen Multicast Groups Table ScreenTo access the Statistics menu Statistics ScreenDiagnostic Tool Ping Terminal Menu To access the Diagnostic Tools menuUsing the Ping Function To ping a hostErasing IR-IP Software Erasing User’s ConfigurationTo erase the user’s configuration Desired positions, and then turn ASM-60 on againTo erase the application software Erasing Application SoftwareDownloading New Software Case, it is recommended to turn ASM-60 off and then back onAppendix C IR-IP Interface Module Erasing IR-IP Software Customer Response Form Excellent Good Fair Poor Very PoorPage Error Report Page Page International Headquarters
Related manuals
Manual 74 pages 54.1 Kb

ASM-60 specifications

The RAD Data Communications ASM-60 is a highly advanced access and service management platform designed to streamline the deployment and management of various telecommunications services. It is particularly well-suited for carrier-grade applications, offering a robust solution that meets the demands of modern communication networks. The ASM-60 integrates multiple functionalities, ensuring that service providers can efficiently manage their networks and deliver high-quality services to their customers.

One of the standout features of the ASM-60 is its versatility. It supports a wide range of technologies, including Ethernet, TDM, and IP-based services. This adaptability allows service providers to seamlessly integrate legacy systems with newer technologies, ensuring a smooth transition as networks evolve. The platform is equipped to handle both synchronous and asynchronous services, catering to diverse customer needs while maximizing operational efficiency.

Reliability is paramount in telecommunications, and the ASM-60 excels in this regard. It boasts built-in redundancy features, ensuring continuous operation even in the event of a hardware failure. The platform is designed with hot-swappable components, allowing for maintenance and upgrades without disrupting service. This characteristic makes it an ideal choice for mission-critical applications that require uninterrupted service delivery.

In terms of scalability, the ASM-60 offers a comprehensive solution for growing networks. With its modular design, service providers can easily expand their infrastructure as demand increases. This scalability ensures that organizations can effectively respond to changing market conditions and customer requirements, facilitating long-term growth.

Another significant aspect of the ASM-60 is its advanced management capabilities. The platform is equipped with a user-friendly interface that simplifies configuration, monitoring, and troubleshooting tasks. It supports various management protocols, including SNMP and Command Line Interface (CLI), enabling seamless integration with existing network management systems.

Security is also a critical consideration in the design of the ASM-60. It features multiple layers of security, including encryption and authentication protocols, to safeguard sensitive data. This commitment to security helps service providers maintain the integrity and confidentiality of their customers’ information.

In conclusion, the RAD Data Communications ASM-60 is a powerful access and service management platform that meets the diverse needs of modern telecommunications networks. With its versatility, reliability, scalability, advanced management capabilities, and robust security features, the ASM-60 is an ideal choice for service providers looking to enhance their operational efficiency and deliver top-notch services to their customers.