RAD Data comm ASM-60 operation manual International Headquarters RAD Data Communications Inc

Page 3

ASM-60

4-Wire Symmetrical VDSL Modem

Installation and Operation Manual

Notice

This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications.

Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to this manual and to the ASM-60 and any software components contained therein are proprietary products of RAD protected under international copyright law and shall be and remain solely with RAD.

ASM-60 is a registered trademark of RAD. No right, license, or interest to such trademark is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark.

You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the ASM-60. You are prohibited from, and shall not, directly or indirectly, develop, market, distribute, license, or sell any product that supports substantially similar functionality as the ASM-60, based on or derived in any way from the ASM-60. Your undertaking in this paragraph shall survive the termination of this Agreement.

This Agreement is effective upon your opening of the ASM-60 package and shall continue until terminated. RAD may terminate this Agreement upon the breach by you of any term hereof. Upon such termination by RAD, you agree to return to RAD the ASM-60 and all copies and portions thereof.

For further information contact RAD at the address below or contact your local distributor.

 

International Headquarters

U.S. Headquarters

 

 

RAD Data Communications Ltd.

RAD Data Communications Inc.

 

 

24 Raoul Wallenberg St.

900 Corporate Drive

 

 

Tel Aviv 69719 Israel

Mahwah, NJ 07430 USA

 

 

Tel: 972-3-6458181

Tel: (201) 529-1100, Toll free: 1-800-444-7234

 

 

Fax: 972-3-6498250

Fax: (201) 529-5777

 

 

E-mail:rad@rad.co.il

E-mail:market@radusa.com

 

 

 

 

 

© 1989–2002 RAD Data Communications Ltd.

Publication No. 145-200-11/02

Image 3
Contents ASM-60 Page International Headquarters RAD Data Communications Inc ASM-60Limited Warranty Please observe the following precautions General Safety InstructionsGeneral Safety Practices Connection of AC MainsConnection of DC Mains Connection of Data and Telecommunications Cables Ports Safety StatusElectromagnetic Compatibility EMC Canadian Emission Requirements Page Supplementary Information SafetyManufacturers Name Manufacturers Address Product NamePage Connecting the Power Installing ASM-60Setting the Internal Switches Connecting the InterfacesSelecting the Data Rate Configuring ASM-60Operating ASM-60 Normal IndicationsContents Diagnostics List of Figures Table of Contents Application Chapter IntroductionOverview VersionsFeatures D View of ASM-60 Physical DescriptionFunctional Description ASM-60 Block DiagramInterface 24/RS-232 Type Technical SpecificationsRange Data RateAC Voltage 100 to 240 VAC ±10%, 50 to 60 Hz, 6W Protection Transformers to the transmit and receive linesFuse 250A, slow-blow Site Requirements and Prerequisites Chapter Installation and SetupInstallation and Setup Package ContentsConnecting the Line Opening the ASM-60 CaseClosing the ASM-60 Case Connecting the DTE Hssi Interface Connector PinoutTo connect the Hssi interface To connect the AC power Installation and Setup Name Function Front Panel IndicatorsLED Indicators Chapter OperationTurning Off ASM-60 ASM-60 Indicator StatusTurning On ASM-60 Normal OperationPreparing Terminal Control Port Interface CharacteristicsChapter Management from a Terminal Preparing for the Control SessionTo choose an option Navigating the Management MenusInitiating a Control Session To initiate a control sessionTerminal Management Menus Starting the Control SessionMain Menu To display the Configuration menuDisplaying the ASM-60 System Information To access the Display menuTo display the ASM-60 status Displaying the ASM-60 StatusTo reset ASM-60 Resetting ASM-60Resetting ASM-60 Alarms Chapter DiagnosticsError Detection Power-Up Self-TestWorking with the Log File To access the log fileNumber Terminal Message Description Severity Displaying the Vdsl Performance DiagnosticsASM-60 Alarms To display the Vdsl diagnosticsASM-60 Performance Monitoring Parameters After the ASM-60 power-upRunning the Diagnostic Tests Running the LEDs TestTo run the LEDs test Running the Diagnostic Tests Appendix a IR-ETH Interface Module IR-ETH Connector OptionsAppendix a IR-ETH Interface Module ProtocolSection Name Description Default Number Setting Installation and OperationDIP Switch Settings Table A-2. DIP Switch SettingsDescription Location Color Name LED IndicatorsConnecting to LAN Table A-3. IR-ETH Bridge LED IndicatorsIR-ETH/QH Connector Appendix B IR-ETH/QH Interface ModuleIntroduction Table B-1 RJ-45 Connector Pinout Pin Signal FunctionProtocol Point-to-point Data Rate Kbps to 45 Mbps Section Name Description Possible Settings Factory Setting Setting the DIP SwitchTable B-2. DIP Switch Settings Table B-3. IR-ETH/QH LED IndicatorsConnecting the LAN Overview Appendix C IR-IP Interface ModuleProtocols Delay FrameConnector 10BaseT UTP Shielded RJ-45 Standard Conforms to Ieee 802.3/Ethernet Data Rate MbpsTable C-3 RJ-45 Pinout IR-IP DIP SwitchIR-IP LEDs Table C-1. IR-IP LEDs FunctionsAccessing the IR-IP Management Subsystem IR-IP Management Subsystem, GeneralIntroduction To perform the preliminary configuration procedure Performing Preliminary ConfigurationDefault IP Communication Parameters Outline of Preliminary ConfigurationIP Learning Mechanism Connecting the Telnet HostPreliminary Telnet Host Configuration Assigning the Router LAN Interface AddressTo view and edit the ARP table contents To configure the IP router LAN addressAssigning a LAN IP Address to a New IR-IP IP learning process is not successful Changing the LAN IP Address of a Configured IR-IPWhat to Do If No ping replies from IR-IPGeneral Operating Procedures IR-IP Management UtilityStarting a Management Utility Quick Setup Menu To access the Quick Setup menuMenu Structure of Management Utility WAN IP Address Default GatewayLAN IP Address LAN IP MaskParameters Read Protocol from DIP SwitchesOperation with Default Gateway ProtocolTo access the Management Access menu Management Access MenuTelnet Password Telnet Inactivity TimeoutDevice Identification Menu Advanced Setup MenuTo access the Advanced Setup menu To access the Device Identification menuInterface Parameters Menu WAN Throttle Aging TimeoutMaintenance Protocol WAN Protocol Parameters Frame Relay Protocol MenuProtocol Field Compression Authentication ProtocolWAN Protocol Parameters PPP Protocol Menu Header and Control Field CompressionUser Name To Send Password To SendPassword To Accept Security Host/GuestTo access the Multicast IP menu Multicast IP MenuMulticast Forwarding Static Groups To access the Static Groups menuTo access the Device Control menu Device Control MenuFile Name Total TimeoutNew Software Download Menu Server IP AddressReset LAN View Error Log ScreenResets Menu Reset DeviceConfiguration and Connection Reset WANView Menu Multicast Groups Table Screen To access the ARP Tables screenTo access the Multicast Groups Table screen ARP TablesStatistics Screen To access the Statistics menuTo access the Diagnostic Tools menu Diagnostic Tool Ping Terminal MenuTo ping a host Using the Ping FunctionDesired positions, and then turn ASM-60 on again Erasing User’s ConfigurationTo erase the user’s configuration Erasing IR-IP SoftwareCase, it is recommended to turn ASM-60 off and then back on Erasing Application SoftwareDownloading New Software To erase the application softwareAppendix C IR-IP Interface Module Erasing IR-IP Software Excellent Good Fair Poor Very Poor Customer Response FormPage Error Report Page Page International Headquarters