The ASM-60 DTE interface provides interface for input/output data, clock reference and control signals between the modem and the DTE. The ASM-60 DTE interface can be either HSSI interface module, terminating in SCSI 50 female connector (see Table 2-2), or one of the Ethernet interface modules, described in greater detail in Appendix A, Appendix B and Appendix C.

To connect the HSSI interface:

Attach the HSSI cable, terminated by SCSI 50 male connector to the SCSI 50 socket on the rear panel of ASM-60.

Table 2-2. HSSI Interface Connector Pinout

Signal Name

Function

ASM-60 Signal

Direction

Pin (+Side)

Pin (-Side)

 

 

 

 

 

 

SG

Signal Ground

 

 

1

26

 

 

 

 

 

 

RT

Receive Timing

IR-DXC

From ASM-60

2

27

 

 

 

 

 

 

CA

DCE Available

DSR

From ASM-60

3

28

 

 

 

 

 

 

RD

Receive Data

IR-RXD

From ASM-60

4

29

 

 

 

 

 

 

LC

Loopback Circuit C

From ASM-60

5

30

 

 

 

 

 

 

ST

Send Timing

IR-TXC

From ASM-60

6

31

 

 

 

 

 

 

SG

Signal Ground

7

32

 

 

 

 

 

 

TA

DTE Available

DTR

8

33

 

 

 

 

 

 

TT

Terminal Timing

IR-EXTC

To ASM-60

9

34

 

 

 

 

 

 

LA

Loopback Circuit A

10

35

 

 

 

 

 

 

SD

Send Data

IR-TXD

To ASM-60

11

36

 

 

 

 

 

 

LB

Loopback Circuit B

12

37

 

 

 

 

 

 

SG

Signal Ground

13

38

 

 

 

 

 

 

5

Ancillary to DCE

14–18

39–43

 

 

 

 

 

 

SG

Signal Ground

19

44

 

 

 

 

 

 

4

Ancillary from DCE

20–23

45–48

 

 

 

 

 

 

TM

Test Mode

24

49

 

 

 

 

 

 

SG

Signal Ground

25

50

 

 

 

 

 

 

2-4

Installation and Setup

Image 28
Contents ASM-60 Page ASM-60 International Headquarters RAD Data Communications IncLimited Warranty General Safety Instructions Please observe the following precautionsConnection of AC Mains General Safety PracticesConnection of DC Mains Ports Safety Status Connection of Data and Telecommunications CablesElectromagnetic Compatibility EMC Canadian Emission Requirements Page Safety Manufacturers Name Manufacturers AddressProduct Name Supplementary InformationPage Installing ASM-60 Setting the Internal SwitchesConnecting the Interfaces Connecting the PowerConfiguring ASM-60 Operating ASM-60Normal Indications Selecting the Data RateContents Diagnostics List of Figures Table of Contents Chapter Introduction OverviewVersions ApplicationFeatures Physical Description D View of ASM-60ASM-60 Block Diagram Functional DescriptionTechnical Specifications RangeData Rate Interface 24/RS-232 TypeTransformers to the transmit and receive lines AC Voltage 100 to 240 VAC ±10%, 50 to 60 Hz, 6W ProtectionFuse 250A, slow-blow Chapter Installation and Setup Site Requirements and PrerequisitesPackage Contents Installation and SetupOpening the ASM-60 Case Connecting the LineClosing the ASM-60 Case Hssi Interface Connector Pinout Connecting the DTETo connect the Hssi interface To connect the AC power Installation and Setup Front Panel Indicators LED IndicatorsChapter Operation Name FunctionASM-60 Indicator Status Turning On ASM-60Normal Operation Turning Off ASM-60Control Port Interface Characteristics Chapter Management from a TerminalPreparing for the Control Session Preparing TerminalNavigating the Management Menus Initiating a Control SessionTo initiate a control session To choose an optionStarting the Control Session Terminal Management MenusTo display the Configuration menu Main MenuTo access the Display menu Displaying the ASM-60 System InformationDisplaying the ASM-60 Status To display the ASM-60 statusResetting ASM-60 To reset ASM-60Resetting ASM-60 Chapter Diagnostics Error DetectionPower-Up Self-Test AlarmsTo access the log file Working with the Log FileDisplaying the Vdsl Performance Diagnostics ASM-60 AlarmsTo display the Vdsl diagnostics Number Terminal Message Description SeverityAfter the ASM-60 power-up ASM-60 Performance Monitoring ParametersRunning the LEDs Test Running the Diagnostic TestsTo run the LEDs test Running the Diagnostic Tests IR-ETH Connector Options Appendix a IR-ETH Interface ModuleProtocol Appendix a IR-ETH Interface ModuleInstallation and Operation DIP Switch SettingsTable A-2. DIP Switch Settings Section Name Description Default Number SettingLED Indicators Connecting to LANTable A-3. IR-ETH Bridge LED Indicators Description Location Color NameAppendix B IR-ETH/QH Interface Module IR-ETH/QH ConnectorIntroduction Pin Signal Function Table B-1 RJ-45 Connector PinoutProtocol Point-to-point Data Rate Kbps to 45 Mbps Setting the DIP Switch Table B-2. DIP Switch SettingsTable B-3. IR-ETH/QH LED Indicators Section Name Description Possible Settings Factory SettingConnecting the LAN Appendix C IR-IP Interface Module OverviewDelay Frame Connector 10BaseT UTP Shielded RJ-45Standard Conforms to Ieee 802.3/Ethernet Data Rate Mbps ProtocolsIR-IP DIP Switch IR-IP LEDsTable C-1. IR-IP LEDs Functions Table C-3 RJ-45 PinoutIR-IP Management Subsystem, General Accessing the IR-IP Management SubsystemIntroduction Performing Preliminary Configuration Default IP Communication ParametersOutline of Preliminary Configuration To perform the preliminary configuration procedureConnecting the Telnet Host Preliminary Telnet Host ConfigurationAssigning the Router LAN Interface Address IP Learning MechanismTo configure the IP router LAN address To view and edit the ARP table contentsAssigning a LAN IP Address to a New IR-IP Changing the LAN IP Address of a Configured IR-IP What to Do IfNo ping replies from IR-IP IP learning process is not successfulIR-IP Management Utility General Operating ProceduresStarting a Management Utility To access the Quick Setup menu Quick Setup MenuMenu Structure of Management Utility Default Gateway LAN IP AddressLAN IP Mask WAN IP AddressRead Protocol from DIP Switches Operation with Default GatewayProtocol ParametersManagement Access Menu Telnet PasswordTelnet Inactivity Timeout To access the Management Access menuAdvanced Setup Menu To access the Advanced Setup menuTo access the Device Identification menu Device Identification MenuInterface Parameters Menu Aging Timeout Maintenance ProtocolWAN Protocol Parameters Frame Relay Protocol Menu WAN ThrottleAuthentication Protocol WAN Protocol Parameters PPP Protocol MenuHeader and Control Field Compression Protocol Field CompressionPassword To Send Password To AcceptSecurity Host/Guest User Name To SendMulticast IP Menu To access the Multicast IP menuMulticast Forwarding To access the Static Groups menu To access the Device Control menuDevice Control Menu Static GroupsTotal Timeout New Software Download MenuServer IP Address File NameView Error Log Screen Resets MenuReset Device Reset LANReset WAN Configuration and ConnectionView Menu To access the ARP Tables screen To access the Multicast Groups Table screenARP Tables Multicast Groups Table ScreenTo access the Statistics menu Statistics ScreenDiagnostic Tool Ping Terminal Menu To access the Diagnostic Tools menuUsing the Ping Function To ping a hostErasing User’s Configuration To erase the user’s configurationErasing IR-IP Software Desired positions, and then turn ASM-60 on againErasing Application Software Downloading New SoftwareTo erase the application software Case, it is recommended to turn ASM-60 off and then back onAppendix C IR-IP Interface Module Erasing IR-IP Software Customer Response Form Excellent Good Fair Poor Very PoorPage Error Report Page Page International Headquarters
Related manuals
Manual 74 pages 54.1 Kb

ASM-60 specifications

The RAD Data Communications ASM-60 is a highly advanced access and service management platform designed to streamline the deployment and management of various telecommunications services. It is particularly well-suited for carrier-grade applications, offering a robust solution that meets the demands of modern communication networks. The ASM-60 integrates multiple functionalities, ensuring that service providers can efficiently manage their networks and deliver high-quality services to their customers.

One of the standout features of the ASM-60 is its versatility. It supports a wide range of technologies, including Ethernet, TDM, and IP-based services. This adaptability allows service providers to seamlessly integrate legacy systems with newer technologies, ensuring a smooth transition as networks evolve. The platform is equipped to handle both synchronous and asynchronous services, catering to diverse customer needs while maximizing operational efficiency.

Reliability is paramount in telecommunications, and the ASM-60 excels in this regard. It boasts built-in redundancy features, ensuring continuous operation even in the event of a hardware failure. The platform is designed with hot-swappable components, allowing for maintenance and upgrades without disrupting service. This characteristic makes it an ideal choice for mission-critical applications that require uninterrupted service delivery.

In terms of scalability, the ASM-60 offers a comprehensive solution for growing networks. With its modular design, service providers can easily expand their infrastructure as demand increases. This scalability ensures that organizations can effectively respond to changing market conditions and customer requirements, facilitating long-term growth.

Another significant aspect of the ASM-60 is its advanced management capabilities. The platform is equipped with a user-friendly interface that simplifies configuration, monitoring, and troubleshooting tasks. It supports various management protocols, including SNMP and Command Line Interface (CLI), enabling seamless integration with existing network management systems.

Security is also a critical consideration in the design of the ASM-60. It features multiple layers of security, including encryption and authentication protocols, to safeguard sensitive data. This commitment to security helps service providers maintain the integrity and confidentiality of their customers’ information.

In conclusion, the RAD Data Communications ASM-60 is a powerful access and service management platform that meets the diverse needs of modern telecommunications networks. With its versatility, reliability, scalability, advanced management capabilities, and robust security features, the ASM-60 is an ideal choice for service providers looking to enhance their operational efficiency and deliver top-notch services to their customers.