RAD Data comm ASM-60 Performing Preliminary Configuration, Default IP Communication Parameters

Page 59

ASM-60Installation and Operation Manual

Appendix C IR-IP Interface Module

 

 

Default IP Communication Parameters

The default IP communication parameters of the interface module are:

The default IP address of the IR-IP Ethernet port is 192.168.205.1, and the default IP subnet mask is 255.255.255.252.

The port will accept IP communication only from the IP address 192.168.205.2. Therefore, as long as the factory defaults are in effect, you must assign this address to the Telnet host used to configure IR-IP.

Using the IP learning mechanism, as explained below you can change the default parameters.

Note In the default configuration, the IR-IP WAN interface is disabled. In order to enable the WAN interface, you have to modify the Ethernet port address or the IP subnet mask.

C.5 Performing Preliminary Configuration

General

The software necessary for performing all the management and configuration functions is stored in the IR-IP interface module, and therefore you only need a regular Telnet host to perform all the activities described in this appendix.

A Telnet host is any computer, e.g., an IBM PC or compatible that fulfills the following minimum requirements:

A standard 10BaseT Ethernet interface

A TCP/IP protocol stack, and therefore is capable of supporting IP communication through the Ethernet interface

Telnet client software

A ping utility.

Outline of Preliminary Configuration

To perform the preliminary configuration procedure:

1.Connect the Telnet host to the IR-IP interface module.

2.Configure the Telnet host to enable communication with the IR-IP interface module using the default IP parameters.

3.Establish communication with IR-IP and assign the prescribed IP address to its LAN interface.

4.Establish again communication with IR-IP and continue the preliminary configuration in accordance with the Quick Setup Menu section below.

Performing Preliminary Configuration

C-5

Image 59
Contents ASM-60 Page International Headquarters RAD Data Communications Inc ASM-60Limited Warranty Please observe the following precautions General Safety InstructionsConnection of DC Mains General Safety PracticesConnection of AC Mains Connection of Data and Telecommunications Cables Ports Safety StatusElectromagnetic Compatibility EMC Canadian Emission Requirements Page Supplementary Information SafetyManufacturers Name Manufacturers Address Product NamePage Connecting the Power Installing ASM-60Setting the Internal Switches Connecting the InterfacesSelecting the Data Rate Configuring ASM-60Operating ASM-60 Normal IndicationsContents Diagnostics List of Figures Table of Contents Application Chapter IntroductionOverview VersionsFeatures D View of ASM-60 Physical DescriptionFunctional Description ASM-60 Block DiagramInterface 24/RS-232 Type Technical SpecificationsRange Data RateFuse 250A, slow-blow AC Voltage 100 to 240 VAC ±10%, 50 to 60 Hz, 6W ProtectionTransformers to the transmit and receive lines Site Requirements and Prerequisites Chapter Installation and SetupInstallation and Setup Package ContentsClosing the ASM-60 Case Connecting the LineOpening the ASM-60 Case To connect the Hssi interface Connecting the DTEHssi Interface Connector Pinout To connect the AC power Installation and Setup Name Function Front Panel IndicatorsLED Indicators Chapter OperationTurning Off ASM-60 ASM-60 Indicator StatusTurning On ASM-60 Normal OperationPreparing Terminal Control Port Interface CharacteristicsChapter Management from a Terminal Preparing for the Control SessionTo choose an option Navigating the Management MenusInitiating a Control Session To initiate a control sessionTerminal Management Menus Starting the Control SessionMain Menu To display the Configuration menuDisplaying the ASM-60 System Information To access the Display menuTo display the ASM-60 status Displaying the ASM-60 StatusTo reset ASM-60 Resetting ASM-60Resetting ASM-60 Alarms Chapter DiagnosticsError Detection Power-Up Self-TestWorking with the Log File To access the log fileNumber Terminal Message Description Severity Displaying the Vdsl Performance DiagnosticsASM-60 Alarms To display the Vdsl diagnosticsASM-60 Performance Monitoring Parameters After the ASM-60 power-upTo run the LEDs test Running the Diagnostic TestsRunning the LEDs Test Running the Diagnostic Tests Appendix a IR-ETH Interface Module IR-ETH Connector OptionsAppendix a IR-ETH Interface Module ProtocolSection Name Description Default Number Setting Installation and OperationDIP Switch Settings Table A-2. DIP Switch SettingsDescription Location Color Name LED IndicatorsConnecting to LAN Table A-3. IR-ETH Bridge LED IndicatorsIntroduction IR-ETH/QH ConnectorAppendix B IR-ETH/QH Interface Module Protocol Point-to-point Data Rate Kbps to 45 Mbps Table B-1 RJ-45 Connector PinoutPin Signal Function Section Name Description Possible Settings Factory Setting Setting the DIP SwitchTable B-2. DIP Switch Settings Table B-3. IR-ETH/QH LED IndicatorsConnecting the LAN Overview Appendix C IR-IP Interface ModuleProtocols Delay FrameConnector 10BaseT UTP Shielded RJ-45 Standard Conforms to Ieee 802.3/Ethernet Data Rate MbpsTable C-3 RJ-45 Pinout IR-IP DIP SwitchIR-IP LEDs Table C-1. IR-IP LEDs FunctionsIntroduction Accessing the IR-IP Management SubsystemIR-IP Management Subsystem, General To perform the preliminary configuration procedure Performing Preliminary ConfigurationDefault IP Communication Parameters Outline of Preliminary ConfigurationIP Learning Mechanism Connecting the Telnet HostPreliminary Telnet Host Configuration Assigning the Router LAN Interface AddressAssigning a LAN IP Address to a New IR-IP To view and edit the ARP table contentsTo configure the IP router LAN address IP learning process is not successful Changing the LAN IP Address of a Configured IR-IPWhat to Do If No ping replies from IR-IPStarting a Management Utility General Operating ProceduresIR-IP Management Utility Menu Structure of Management Utility Quick Setup MenuTo access the Quick Setup menu WAN IP Address Default GatewayLAN IP Address LAN IP MaskParameters Read Protocol from DIP SwitchesOperation with Default Gateway ProtocolTo access the Management Access menu Management Access MenuTelnet Password Telnet Inactivity TimeoutDevice Identification Menu Advanced Setup MenuTo access the Advanced Setup menu To access the Device Identification menuInterface Parameters Menu WAN Throttle Aging TimeoutMaintenance Protocol WAN Protocol Parameters Frame Relay Protocol MenuProtocol Field Compression Authentication ProtocolWAN Protocol Parameters PPP Protocol Menu Header and Control Field CompressionUser Name To Send Password To SendPassword To Accept Security Host/GuestMulticast Forwarding To access the Multicast IP menuMulticast IP Menu Static Groups To access the Static Groups menuTo access the Device Control menu Device Control MenuFile Name Total TimeoutNew Software Download Menu Server IP AddressReset LAN View Error Log ScreenResets Menu Reset DeviceView Menu Configuration and ConnectionReset WAN Multicast Groups Table Screen To access the ARP Tables screenTo access the Multicast Groups Table screen ARP TablesStatistics Screen To access the Statistics menuTo access the Diagnostic Tools menu Diagnostic Tool Ping Terminal MenuTo ping a host Using the Ping FunctionDesired positions, and then turn ASM-60 on again Erasing User’s ConfigurationTo erase the user’s configuration Erasing IR-IP SoftwareCase, it is recommended to turn ASM-60 off and then back on Erasing Application SoftwareDownloading New Software To erase the application softwareAppendix C IR-IP Interface Module Erasing IR-IP Software Excellent Good Fair Poor Very Poor Customer Response FormPage Error Report Page Page International Headquarters
Related manuals
Manual 74 pages 54.1 Kb

ASM-60 specifications

The RAD Data Communications ASM-60 is a highly advanced access and service management platform designed to streamline the deployment and management of various telecommunications services. It is particularly well-suited for carrier-grade applications, offering a robust solution that meets the demands of modern communication networks. The ASM-60 integrates multiple functionalities, ensuring that service providers can efficiently manage their networks and deliver high-quality services to their customers.

One of the standout features of the ASM-60 is its versatility. It supports a wide range of technologies, including Ethernet, TDM, and IP-based services. This adaptability allows service providers to seamlessly integrate legacy systems with newer technologies, ensuring a smooth transition as networks evolve. The platform is equipped to handle both synchronous and asynchronous services, catering to diverse customer needs while maximizing operational efficiency.

Reliability is paramount in telecommunications, and the ASM-60 excels in this regard. It boasts built-in redundancy features, ensuring continuous operation even in the event of a hardware failure. The platform is designed with hot-swappable components, allowing for maintenance and upgrades without disrupting service. This characteristic makes it an ideal choice for mission-critical applications that require uninterrupted service delivery.

In terms of scalability, the ASM-60 offers a comprehensive solution for growing networks. With its modular design, service providers can easily expand their infrastructure as demand increases. This scalability ensures that organizations can effectively respond to changing market conditions and customer requirements, facilitating long-term growth.

Another significant aspect of the ASM-60 is its advanced management capabilities. The platform is equipped with a user-friendly interface that simplifies configuration, monitoring, and troubleshooting tasks. It supports various management protocols, including SNMP and Command Line Interface (CLI), enabling seamless integration with existing network management systems.

Security is also a critical consideration in the design of the ASM-60. It features multiple layers of security, including encryption and authentication protocols, to safeguard sensitive data. This commitment to security helps service providers maintain the integrity and confidentiality of their customers’ information.

In conclusion, the RAD Data Communications ASM-60 is a powerful access and service management platform that meets the diverse needs of modern telecommunications networks. With its versatility, reliability, scalability, advanced management capabilities, and robust security features, the ASM-60 is an ideal choice for service providers looking to enhance their operational efficiency and deliver top-notch services to their customers.