1Locate the faulty fan indicated by the diagnostic software.

2Turn off the system and all attached peripherals.

3Open the system. See "Opening the System" on page 50.

4Reseat the fan's power cable.

5Restart the system.

If the fan functions properly, close the system. See "Closing the System" on page 51.

6If the fan does not function, turn off the system and install a new fan. See "Cooling Fans" on page 74.

7Restart the system.

If the problem is resolved, close the system. See "Closing the System" on page 51.

If the replacement fan does not operate, see "Getting Help" on page 119.

Troubleshooting System Memory

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

NOTE: Invalid memory configurations can cause your system to halt at startup without video output. See General Memory Module Installation Guidelines and verify that your memory configuration complies with all applicable guidelines.

1If the system is operational, run the appropriate online diagnostic test. See "Running the System Diagnostics" on page 111.

If diagnostics indicates a fault, follow the corrective actions provided by the diagnostic program.

2If the system is not operational, turn off the system and attached peripherals, and unplug the system from the power source. Wait at least 10 seconds and then reconnect the system to power.

3Turn on the system and attached peripherals and note the messages on the screen.

104

Troubleshooting Your System

Image 104
Contents Dell PowerEdge R210 II Systems February Contents Using the Boot Manager Navigation Keys Embedded System ManagementOpening and Closing the System IDRAC6 Express Card Optional IDRAC6 Enterprise Card OptionalTroubleshooting a Wet System Troubleshooting a Damaged SystemTroubleshooting the System Battery Troubleshooting Power SupplyDisabling a Forgotten Password 118 111115 116Index Contents Accessing System Features During Startup Keystroke DescriptionFront-Panel Features and Indicators Power to the system is turned offIndicator, Button, or Icon Description Connector Back-Panel Features and Indicators Guidelines for Connecting External Devices NIC Indicator Codes Indicator Indicator CodeDiagnostic Lights Diagnostic Indicator Codes Causes Corrective ActionCode Causes Corrective Action System Messages Message Causes Corrective ActionsKeyboard cable connector is Reseat the keyboard cable. If There is no device connected Information only Diagnostics Messages Alert MessagesOther Information You May Need About Your System Using the System Setup Program and Boot Manager Choosing the System Boot ModeEntering the System Setup Program Responding to Error MessagesUsing the System Setup Program Navigation Keys Keys ActionOption Description System Setup OptionsMain Screen Option Description System event log Memory Settings ScreenProcessor Settings Screen Sata Settings Screen Running virtualization softwareBoot Settings Screen Not installed in the same boot modeIntegrated Devices Screen Emulation Type fieldsPCI IRQ Assignments Screen NIC2Serial Communication Screen Serial Device 1=COM1 Serial Device2=COM2Power Management Screen OS Control defaultKeys prior to enabling this option System Security ScreenOff Delay Immediate Exit ScreenEntering the Boot Manager Using the Boot Manager Navigation Keys Boot Manager ScreenBoot Settings Screen Boot Mode BiosBoot Mode Uefi System Utilities ScreenAssigning a System Password System and Setup Password FeaturesUsing the System Password Using Your System Password to Secure Your System Assigning a Setup Password Using the Setup PasswordDeleting or Changing an Existing System Password Embedded System Management Operating With a Setup Password EnabledDeleting or Changing an Existing Setup Password Baseboard Management Controller Configuration Entering the BMC Setup ModuleIDRAC6 Configuration Utility Entering the iDRAC6 Configuration UtilityUsing the System Setup Program and Boot Manager Installing System Components Recommended ToolsInside the System Inside the SystemRemoving the Front Bezel Installing the Front BezelFront Bezel Optional Opening and Closing the System Opening the SystemClosing the System Optical Drive Optional Removing an Optical DriveRemoving and Installing the Optical Drive Installing an Optical Drive Filler PanelInstalling a Filler Panel Removing a Filler PanelHard Drives Removing a 3.5-Inch Hard DriveRemoving and Installing a 3.5-Inch Hard Drive Installing a 3.5-Inch Hard Drive Removing a 3.5-Inch Hard Drive From a Hard-Drive Carrier Installing a 3.5-Inch Hard Drive Into a Hard-Drive Carrier Removing a 3.5-Inch Hard Drive From a Hard-Drive CarrierRemoving an Expansion Card Expansion Card Installation GuidelinesExpansion Card Installing an Expansion Card Expansion-Card Riser Removing an Expansion-Card RiserRemoving and Installing an Expansion-Card Riser Installing an Expansion-Card Riser Internal USB Memory Key10. Removing and Installing a USB Memory Key Cooling ShroudRemoving the Cooling Shroud 11. Removing and Installing the Cooling Shroud System Memory Installing the Cooling ShroudGeneral Memory Module Installation Guidelines Memory GB Sample Udimm Memory Configuration Memory Sockets PhysicalMode-Specific Guidelines Installing Memory Modules 12. Removing and Installing a Memory Module Removing Memory Modules Cooling Fans Removing a Cooling FanInstalling a Cooling Fan 13. Removing and Installing a FanInstalling an iDRAC6 Express Card IDRAC6 Express Card Optional14. Removing and Installing an iDRAC6 Express Card Removing an iDRAC6 Express Card Installing an iDRAC6 Enterprise Card IDRAC6 Enterprise Card Optional15. Removing and Installing an iDRAC6 Enterprise Card Removing an iDRAC6 Enterprise Card Installing a VFlash Media Card VFlash Media OptionalProcessor Removing a VFlash Media CardInstalling System Components 16. Removing and Installing the Heat Sink 17. Removing and Installing a Processor Installing a Processor Power Supply Removing the Power Supply18. Removing and Installing the Power Supply Replacing the System Battery System BatteryInstalling the Power Supply 19. Replacing the System Battery Control Panel Assembly Removing the Control Panel Assembly20. Removing and Installing the Control Panel Removing the System Board Installing the Control Panel AssemblySystem Board Installing System Components Installing the System Board 21. Removing and Installing the System BoardInstalling System Components Troubleshooting Your System Troubleshooting External ConnectionsTroubleshooting the Video Subsystem Troubleshooting a USB DeviceTroubleshooting a Serial I/O Device Troubleshooting a NICTroubleshooting a Wet System 100 Troubleshooting a Damaged System 101Troubleshooting the System Battery 102Troubleshooting Power Supply Troubleshooting System Cooling ProblemsTroubleshooting a Fan 103Troubleshooting System Memory 104105 Troubleshooting an Internal USB Key 106Troubleshooting an Optical Drive 107Troubleshooting a Hard Drive 108Troubleshooting an Expansion Card 109Troubleshooting the Processor 110111 Using Online DiagnosticsEmbedded System Diagnostics Features When to Use the Embedded System Diagnostics Running the Embedded System DiagnosticsSystem Diagnostics Testing Options Testing Option FunctionUsing the Custom Test Options Selecting Devices for TestingSelecting Diagnostics Options Viewing Information and Results114 115 System Board Jumper Settings DescriptionSystem Board Jumpers System Board Connectors 116System Board Jumpers and Connectors Description 117Disabling a Forgotten Password 118Contacting Dell 119120 Index 121122 Post 123124 125 126