Promise Technology 150TX2 user manual Viewing Drive Assignments, Creating Multiple Arrays

Page 28

FastTrak S150 TX2plus User Manual

Creating Multiple Arrays

If you plan to create multiple arrays,

1.Attach only the drives necessary to create the first disk array and complete the Auto Setup (1).

2.Install the additional drives needed for the second array and again use the Auto Setup (1).

Note

If you wish to customize the settings of individual disk arrays (such as block size), you must manually create disk arrays with the Define Array (3) option from the Main Menu.

Viewing Drive Assignments

The View Drive Assignments (2) option in the Main Menu displays whether drives are assigned to a disk array or are unassigned.

Under the Assignment column, drives are labeled with their assigned disk array or shown as Free if unassigned. Such Free drives can be used for a future array or used as a spare drive when a drive fails in a mirrored array, provided the free drive’s capacity is equal to or larger than the smallest array member.

Unassigned drives are not accessible by the OS. The menu also displays the data transfer mode that relates to speed used by each drive (U5 refers to 100MB/sec transfers, U4 refers to 66MB/sec transfers, etc...)

FastBuild (tm) Utility 2.xx (c) 2002-2005 Promise Technology, Inc.

[ View Drive Assignments ]

Channel:ID

Drive Model

Capacity(MB)

Assignment

Mode

1

:

SEAGATE S380023AS

80024

Array 1

U

2

:

SEAGATE S380023AS

80024

Array 1

U

3

: Slave

WDC WD400BB-53DEA0 40020

Free

U

3

: Master

WDC WD400BB-53DEA0 40020

Free

U

 

 

 

[ Keys Available ]

 

 

[

] Up [] Down [ESC] Exit

Mode (U=UDMA, D=DMA)

 

24

Image 28
Contents Fasttrak S150 TX2PLUS Trademarks CopyrightImportant Data Protection Information Contents Page Introduction FastTrak S150 TX2plusPromise Array Management Utility PAM Key Features and Benefits Features BenefitsCompatibility Installation Unpacking Your FastTrak CardInstalling the FastTrak Card Insert the FastTrak card into an open PCI slotInstalling the Hard Drives FastTrak S150 TX2plus card Creating Your Disk Array Creating a Performance Array Creating a Security Array with New Drives Page Creating a Security Array with an Existing Data Drive Seagate S380023AS Installation Creating a Security Array with Quick Initialization Installation Page Using FastBuild Configuration Utility Viewing FastTrak S150 TX2plus Bios ScreenNavigating the FastBuild Setup Menu Using the Main MenuOptimize Array for Creating Arrays AutomaticallyPerformance Security Security and PerformanceUsing a Hot Spare Drive Viewing Drive Assignments Creating Multiple ArraysManually Creating an Array Selecting Array Type Selecting Stripe BlockGigabyte Boundary Assigning Drives to Array Creating a Striped ArrayCreating a Mirrored Array Using New Drives Adding Fault Tolerance to an Existing Drive Drive Model Capacity MB Page How FastTrak S150 TX2plus Orders Arrays Creating a Hot Spare Drive for Mirrored ArraysHow FastTrak S150 TX2plus Saves Array Information Deleting an Array Array Stripe 160048 Rebuilding a Mirrored Array 80024 Page Installing Software Drivers Procedure NumberWindows XP Installation Existing Windows XP Installation Confirming Windows XP Driver InstallationNew Windows 2000 Installation Existing Windows 2000 Installation Confirming Windows 2000 Driver InstallationNew Windows ME Installation Existing Windows ME Installation Confirming Windows ME Driver InstallationNew Windows NT4.0 Installation Existing Windows NT4.0 Installation Removing Driver from Windows NT4.0New Windows 98 Installation Existing Windows 98 Installation Confirming Windows 98 Driver InstallationPage About Adapter Bios FastBuild Auto Menu SetupAbout FastTrak S150 TX2plus Reserve SectorRAID Level Performance Fault Capacity No. Tolerance Drives Disk Array TermsDisk Array Description Disk Array MemberAbout RAID Levels Striping RAIDMirroring RAID Data Mirror Disk DrivesDisk Array Concepts Striping / Mirroring RAID 0+1 Motherboard Issues Configuring PCI IRQ resourcesIntermittent data problems Freeing additional IRQ resourcesSystem Cmos Issues Using an Onboard IDE Card with FastTrak S150 TX2plusDrive-Related Errors Critical Array Status Error Reported during BootDrive cannot be formed into an array System Cmos displays C or D drive failure during StartupUnable to Partition or Format Array Cannot Rebuild Mirrored RAID 1 Array Operating System-Related Issues Promise Windows driver does not appear in Device ManagerTroubleshooting & Tips Performance Tips Optimize Array for PerformanceChange Setting of PCI Bus Utilization Page Appendix a Frequently Asked Questions Pre-InstallationRAID 1 Mirror RAID 0 StripeRAID 0+1 Stripe + Mirror Drive Issues Page Installation Issues Post-InstallationPage USA Tech Support Center Technical Support ServicesEuropean Tech Support Pacific Rim Sales Office China OfficeLimited Warranty Disclaimer of other warrantiesYour Responsibilities Returning Product for Repair