FastTrak S150 TX2plus User Manual
Critical – Degraded array condition due to a failed or removed disk drive. Applies to mirrored arrays (RAID 1 and 0+1) only. Fault tolerance is lost but the data is still accessible. Triggers automatic rebuilding.
Offline – Striped arrays (RAID 0): Degraded array condition due to one failed or removed disk drive. The data is not accessible.
Mirrored arrays (RAID 1 and 0+1): Degraded array condition due to two failed or removed disk drives. Fault tolerance is lost. The data is not accessible.
If your array goes Offline, contact Promise Technical Support for assistance. See Appendix B.
Navigating the FastBuild Setup Menu
When using the menus, these are some of the basic navigation tips: Arrow keys highlights through choices; the Space bar allows to cycle through options; Enter selects an option; Esc aborts or exits the current menu.
Using the Main Menu
This is the first option screen when entering the FastBuild Setup.
FastBuild (tm) Utility 2.xx (c)
Auto Setup | [ 1 ] |
View Drive Assignments | [ 2 ] |
Define Array | [ 3 ] |
Delete Array | [ 4 ] |
Rebuild Array | [ 5 ] |
[ Keys Available ]
Press 1...5 to Select Option [ESC] Exit
To create a new array automatically, follow the steps under Creating Arrays Automatically on page 17. Promise recommends this option for most users.
To manually create an array, see Manually Creating an Array on page 21.
You will also need to manually create an array if you wish to modify block size. To view drives assigned to arrays, see Viewing Drive Assignments on page 20.
To delete an array (but not delete the data contained on the array), see Deleting an Array on page 28.
To rebuild a mirrored array, see Rebuilding a Mirrored Array on page 30.
20