JAI TM-1400 operation manual 02S Interface Cable optional

Page 19

Page 12

Installation

When wiring the PD-12UU power supply directly, please note the following:

The lead ends must be twisted together and tin-soldered for strength and electrical continuity.

Shrink tubing or a similar insulator should be used to prevent exposed leads from touching and shorting.

The +12V lead is marked with a red stripe or white lettering; be sure not to reverse the leads.

All connections must be properly insulated to prevent shorting.

2.2.7 (b) JAI PULNiX Power Cables

If you are using JAI PULNiX power cables such as the 12P-02S, please refer to the 12-pin connector pin-out diagram in “12-Pin Connector (TM-1400)” on page 6. The cable pin-out diagram is shown in Figure 7 below. The color-coded leads use Gray for Ground and Yellow for +12V.

FIGURE 7. 12P-02S Interface Cable (optional)

 

 

+12 V

 

GND (Gray)

 

 

Jack

Power (Yellow)

 

 

 

Video Out (Red Coax)

}

 

HD In (White Coax)

 

 

VD In (Black Coax)

 

Analog

Frame Grabber

12P-02S Interface Cable

Pin#

Lead Color

Function

Pin#

Lead Color

Function

 

 

 

 

 

 

1

Gray

GND

7

Black coax

VD Input

 

 

 

 

 

 

2

Yellow

+12V DC

8

White coax shield

Reserved

 

 

 

 

 

 

3

Red coax shield

GND

9

White coax

HD Input

 

 

 

 

 

 

4

Red coax

Video

10

Brown

RXD

 

 

 

 

 

 

5

Orange coax shield

GND

11

Blue

Integration

 

 

 

 

 

 

6

Orange coax

VINIT IN

12

Black coax shield

TXD

 

 

 

 

 

 

Note: Make sure that the unused leads are not touching and that there is no possibility that exposed wires could cause the leads to short.

2.2.7 (c) Building Your Own Power Cable

Refer to the 12-pin connector pin-out in Section 2.2.2 (a on page 6. Connect the Ground lead to pin #1, and the +12V DC lead to pin #2 of the 12-pin connector. Power must be DC-regulated, and of sufficient current to properly power the camera.

2.2.7 (d) Attaching the Power Cable to the Connector

The 12-pin connector is keyed and will only fit in one orientation. Follow these directions to properly attach the power cable to the camera connector:

1.Rotate the connector while applying slight pressure until the keyways line up.

2.Press the connector into place until firmly seated.

3.Plug the power cord into the AC socket. This will power the camera up.

TM-1400 Series Progressive Scan Shutter Cameras

Image 19
Contents TM-1400 Series Progressive Scan Shutter Cameras JAI PULNiX, Inc CE CompliancePage Table of Contents InstallationTroubleshooting List of Figures TM-1400 System ConfigurationList of Tables May 2 Product DescriptionIntroduction FeaturesFunctional Options WarrantyIntegration TM-1400 System Configuration System ConfigurationGetting Started Camera SetupPin Description Connector Pin ConfigurationsLDV Pin # DescriptionSerToFG Differential Serial Communication to frame grabber Normal Async Installation 4 RS-232 Communication Cable TM-1400 onlyShutter Speed Control Dial TM-1400 only Shutter Exposure Time SecondsPinout Configuration for Digital Output Cable Installation Digital Output Cable TM-1400 onlyPower Supplies and Power Cable Setup Installation Camera Link Cable CL Versions Only02S Interface Cable optional Attaching the Camera Lens Installation Attaching the Analog Video OutputCamera Rear Panel TM-1400 Mode Selection Switch Camera Rear Panel CL Versions Power and External Sync ConnectorProgressive Scanning Electronic Shutter Asynchronous ResetExternal Vinit With Pulse Width Internal Shutter Speed Control No-Delay ShutterProgrammable Look-Up Table LUT and Knee Control Dynamic Range ControlFull Progressive Scan Scan ModesExternal Sync Bayer Color Filter Color VersionsBayer Color Filter Array CFA Operation Color Filter ArraySync and Data Operation Starting Pixel ConfigurationFDV Camera FunctionsColor Interpolation Operation Interpolation SoftwareManufacturer Frame Grabber Software Tcc =14 nsec, Tdc = 6 nsec, Thd = 5 nsec Horizontal Signals Camera Timing ChartsAsync Shutter Reset Timing Operation Mode 15 Frame /sec Async Shutter Reset Timing Async Shutter Reset Timing Partial Scan 500 Lines Async Shutter Reset Timing Partial Scan 250 Lines Serial Communication Kit CS-232C not required for CL version Symptom Dark Video Problems and SolutionsTroubleshooting Symptom No VideoInformation and Support Resources Appendix SpecificationsModel TM-1400 series Effective Image Area Physical DimensionsSpectral Response Physical Dimensions TM-1400CLW . j a i p u l n i x . c o m