JAI TM-1400 operation manual CE Compliance, JAI PULNiX, Inc

Page 2

i Notice Page

Notice

The material contained in this manual consists of information that is proprietary to JAI PULNiX, Inc., and may only be used by the purchasers of the product. JAI PULNiX, Inc. makes no warranty for the use of its product and assumes no responsibility for any errors which may appear or for damages resulting from the use of the information contained herein. JAI PULNiX, Inc. reserves the right to make changes without notice.

Microsoft, Windows 95, 98, NT, 2000, XP, and Windows Explorer are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.

Warranty

Please contact your factory representative for details about the warranty.

Certifications

CE Compliance

The TM-1400 series of cameras has been certified to conform to the requirements of Council Directive 89/336/EC for electro- magnetic compatibility and to comply with the following European Standards:

Immunity: EN50082-2/1997

Emissions: CISPR22: 1997/EN55011: 1998 Class A

All JAI PULNiX products bearing the CE mark have been declared to be in conformance with the applicable EEC Council Directives. However, certain factory-installed options or customer-requested modifications may compromise electromagnetic compatibility and affect CE compliance. Please note that the use of interconnect cables that are not properly grounded and shielded may affect CE compliance.

Contact the JAI PULNiX Applications Engineering Department for further information regarding CE compliance.

FCC

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Oper- ation of this equipment in a residential area may cause harmful interference, in which case the user will be required to correct the interference at his own expense.

WARNING

Changes or modifications to this unit not expressly approved by the party responsible for

FCC compliance could void the user’s authority to operate the equipment.

TM-1400 Series Operation Manual

JAI PULNiX, Inc.

1330 Orleans Drive

Sunnyvale, CA 94089 Tel:(408) 747-0300 Tel:(800) 445-5444 Fax:(408) 747-0880

E-mail: imaging@jaipulnix.com

www.jaipulnix.com

 

 

 

E

D

 

 

 

 

AT

I

 

 

 

M

 

 

 

T

O

 

MA

A

U

 

 

I

 

 

 

N

 

 

 

 

G

 

 

 

MEMBER

A

N

S

IO

 

SOCIAT

FILE #

R

U

 

M

 

 

A3942 E

 

 

 

 

G

 

® L R

 

I

 

 

F

I

 

S

D

 

 

 

T

 

 

 

 

 

E RE

 

 

JAI PULNiX, INC.

ISO-9001

TM-1400 Series Progressive Scan Shutter Camera

Image 2
Contents TM-1400 Series Progressive Scan Shutter Cameras CE Compliance JAI PULNiX, IncPage Installation Table of ContentsTroubleshooting TM-1400 System Configuration List of FiguresList of Tables Product Description May 2Features IntroductionIntegration WarrantyFunctional Options System Configuration TM-1400 System ConfigurationCamera Setup Getting StartedConnector Pin Configurations Pin DescriptionPin # Description LDVSerToFG Differential Serial Communication to frame grabber Shutter Exposure Time Seconds Installation 4 RS-232 Communication Cable TM-1400 onlyShutter Speed Control Dial TM-1400 only Normal AsyncInstallation Digital Output Cable TM-1400 only Pinout Configuration for Digital Output CableInstallation Camera Link Cable CL Versions Only Power Supplies and Power Cable Setup02S Interface Cable optional Installation Attaching the Analog Video Output Attaching the Camera LensCamera Rear Panel TM-1400 Mode Selection Switch Progressive Scanning Power and External Sync ConnectorCamera Rear Panel CL Versions External Vinit With Pulse Width Asynchronous ResetElectronic Shutter No-Delay Shutter Internal Shutter Speed ControlDynamic Range Control Programmable Look-Up Table LUT and Knee ControlBayer Color Filter Color Versions Scan ModesExternal Sync Full Progressive ScanOperation Color Filter Array Bayer Color Filter Array CFAOperation Starting Pixel Configuration Sync and DataCamera Functions FDVManufacturer Frame Grabber Software Operation Interpolation SoftwareColor Interpolation Camera Timing Charts Tcc =14 nsec, Tdc = 6 nsec, Thd = 5 nsec Horizontal SignalsAsync Shutter Reset Timing Operation Mode 15 Frame /sec Async Shutter Reset Timing Async Shutter Reset Timing Partial Scan 500 Lines Async Shutter Reset Timing Partial Scan 250 Lines Serial Communication Kit CS-232C not required for CL version Symptom No Video Problems and SolutionsTroubleshooting Symptom Dark VideoInformation and Support Resources Model TM-1400 series SpecificationsAppendix Physical Dimensions Effective Image AreaPhysical Dimensions TM-1400CL Spectral ResponseW . j a i p u l n i x . c o m