Basic Troubleshooting Checks

 

Failures of a general nature (affecting many cards and/or functions

 

simultaneously), or gross inoperability errors are best addressed first by

 

performing basic checks before proceeding further. Table 3-4 provides basic

 

system checks that typically locate the source of most general problems. If

 

required and applicable, perform further troubleshooting in accordance with

 

the other troubleshooting tables in this section.

Table 3-4 Basic Troubleshooting Checks

 

 

Item

Checks

 

 

Verify power presence and

• On both the frame Network Controller Card and the 9084, in all cases when power is

characteristics

being properly supplied there is always at least one indicator illuminated. Any card

 

showing no illuminated indicators should be cause for concern.

 

• Check the Power Consumed indications for both the +12 V and -7.5 V supply rails

 

for the 9084 card. This can be observed using the DashBoard™ Card Info pane, or

 

using the card edge controls and indicators as shown in Figure 3-7on page 3-12.

 

• If either of the rail supplies show no power being consumed, either the frame

 

power supply, connections, or the 9084 card itself is defective.

 

• If either of the rail supplies show excessive power being consumed (see

 

Technical Specifications (p. 1-11)in Chapter 1, “Introduction”), the 9084 card

 

may be defective.

 

 

Check Cable connection

Make certain all cable connections are fully secure (including coaxial cable attachment

secureness and connecting

to cable ferrules on BNC connectors). Also, make certain all connecting points are as

points

intended. Make certain the selected connecting points correlate to the intended card

 

inputs and/or outputs. Cabling mistakes are especially easy to make when working

 

with large I/O modules.

 

 

Card seating within slots

Make certain all cards are properly seated within its frame slot. (It is best to assure

 

proper seating by ejecting the card and reseating it again.)

 

 

Check status indicators and

On both DashBoard™ and the 9084 card edge indicators, red indications signify an

displays

error condition. If a status indicator signifies an error, proceed to the following tables in

 

this section for further action.

 

 

Troubleshoot by substitution

All cards within the frame can be hot-swapped, replacing a suspect card or module

 

with a known-good item.

 

 

3-38

9084 PRODUCT MANUAL

9084-OM (V4.0)

Image 62
Contents 9084 Cobalt Digital IncTrademark Information CopyrightDisclaimer Table of Contents Operating Instructions Introduction OverviewCard Software Versions and this Manual SupportDownloads link atManual Conventions E201Safety Summary Labeling Symbol DefinitionsFunctional Description Input/OutputsColor Corrector ProcessorVideo Frame Sync Function Color CorrectorVideo Processor AFD InserterCard Edge Controls Computer with NIC DashBoard Remote ControlUser Control Interface Controller CardOther cards installed in openGear frames such as the Cobalt Raster Structure Frame Rate Rear I/O ModulesVideo Formats Supported by Technical Specifications CharacteristicTechnical Specifications Introduction Warranty and Service Information Cobalt Digital Inc. Limited WarrantyFax Contact Cobalt Digital IncPhone Web General Information Technical SupportThis page intentionally blank Installation and Setup Installing the 9084 Into a Frame SlotInstalling the 9084 Into a Frame Slot Installation and Setup Installing a Rear I/O ModuleSetting Up 9084 Network Remote Control Rear I/O Module InstallationOperating Instructions Control and Display DescriptionsFunction Submenu/Parameter Submenu Overview Submenu a Submenu b Submenu z Individual ParametersCard Edge Controls, Indicators, and Display FunctionNone Card Edge Control Menu/Submenu StructureMenu Depth LEDs Submenu Depth Card Edge Setup Abbreviated DiagramVid ClrCS p DashBoard User Interface Correction Set Enable to OnChannel Black Adj Cobalt Remote Control Panel User Interfaces Control Panel Setup of Example Video Proc FunctionAccessing the 9084 Card via Remote Control Accessing the 9084 Card Using DashBoardAccessing the 9084 Card Using a Cobalt Remote Control Panel Checking 9084 Card Information Checking Card Using Info Card Edge ControlsPower Consumption and Temperature Displays Software Version NumberFormat Default Line No. / RangeAncillary Data Line Number Locations and Ranges Line No. Limiting FormatFunction Submenu List and Descriptions Function Submenu ItemLuma Gain Reset to UnityVideo Proc Luma LiftGang Luma and Color Gain Color PhaseColor Gain Black Hard ClipCard Edge Control Menu Applies white hard clip limiting at specified percentage50.0% to 109.1% null = 109.1% Applies white soft clip limiting at specified percentageOutput Code Output ModeIncoming AFD Output LineOperating Instructions Black Adj. Green Red BlueGang Black Level Controls White Adj. Green Red BlueGang Gamma Controls Horizontal Delay Control Framesync EnableVertical Delay Control Minimum Latency Frames Control Video Delay DisplayLoss of Input Signal Selection Framesync Status DisplayCustom Color Hue Reset FramesyncFramesync LOS Freeze Color Custom Color SaturationPreset Save and Load Preset Name field and Preset Save buttonPreset Load button and the Selected Preset Selected Preset drop-down listPreset Name Reset Current PresetFunction Parameter/Setting Video Proc Download PresetsOn-Set Monitor Color Correction Example Color and Video Correction Examples UsingFeed To Switcher Anchor Desk Set with Monitor10 Uncorrected Uncompensated Monitor Waveform To Switcher From Monitor Video Feed 12 Applying Correction to Example Monitor Waveform Signal Condition Observed On Waveform Monitor Correction Using Miscellaneous Color and Video Correction ExamplesLuma gain less than 100% level as shown below for VAR10.PNG VAR10A.PNG Troubleshooting Error and Failure Indicator OverviewCharacter Alphanumeric Display Card Edge Status/Error Indicators and DisplayStatus/Error Input Format Indicators Indicators AlphanumericDashBoard Status/Error Indicators and Displays Indicator Icon or Display Error Description15 Selecting Specific Cards for Card Info Status Display Basic Troubleshooting Checks ChecksProcessing Error Troubleshooting Symptom Error/Condition Corrective ActionTroubleshooting Network/Remote Control Errors Case of ProblemsPage 2406 E. University Ave. Urbana, IL 9084-OM