Cobalt Networks 9084 manual Troubleshooting Network/Remote Control Errors, Case of Problems

Page 64

3

 

 

Troubleshooting

 

 

 

 

 

 

 

 

Table 3-5 Troubleshooting Processing Errors by Symptom — continued

 

 

 

 

 

 

 

 

Symptom

Error/Condition

Corrective Action

 

 

 

 

 

 

 

 

 

DashBoard™ shows

Specified Minimum Latency

• Reduce the Minimum Latency Frames setting

 

 

 

Framesync Status error

Frames setting exceeds 9084

as specified in the error message to correct

 

 

 

message in 9084 Framesync

card buffer space for the

the error.

 

 

 

function submenu screen.

selected output video format

Note: Due to card memory limits, the maximum

 

 

 

 

 

available Minimum Latency Frames is

 

 

 

 

 

related to the output video format.

 

 

 

 

 

For example, with a 1080i59.94 output, the

 

 

 

 

 

maximum allowed setting is 5. For a 1080i

 

 

 

 

 

film (23.98) output, the maximum allowed

 

 

 

 

 

setting is 3. Conversely, greater maximum

 

 

 

 

 

settings are allowed for SD formats such as

 

 

 

 

 

525i59.94, where the practical maximum

 

 

 

 

 

limit is 13.

 

 

 

 

 

 

 

 

 

Ancillary data (closed captioning,

• Control(s) not enabled

• Make certain respective control is set to On or

 

 

 

timecode, AFD, etc.) not

 

Enabled (as appropriate).

 

 

 

transferred through 9084.

 

 

 

 

 

• VANC line number conflict

• Make certain each ancillary data item to be

 

 

 

 

 

 

 

 

between two or more

passed is assigned a unique line number (see

 

 

 

 

ancillary data items

Ancillary Data Line Number Locations and

 

 

 

 

 

Ranges on page 3-13).

 

 

 

 

 

 

Troubleshooting Network/Remote Control Errors

 

 

 

 

 

Refer to Cobalt® reference guide “COMPASS™ Remote Control User

 

 

 

Guide” (PN 9000RCS-RM) for network/remote control troubleshooting

 

 

 

information.

 

 

In Case of Problems

 

 

 

 

 

 

Should any problem arise with this product that was not solved by the

 

 

 

information in this section, please contact the Cobalt Digital Inc. Technical

 

 

 

Support Department.

 

 

 

 

 

If required, a Return Material Authorization number (RMA) will be issued to

 

 

 

you, as well as specific shipping instructions. If required, a temporary

 

 

 

replacement item will be made available at a nominal charge. Any shipping

 

 

 

costs incurred are the customer’s responsibility. All products shipped to you

 

 

 

from Cobalt Digital Inc. will be shipped collect.

 

 

 

The Cobalt Digital Inc. Technical Support Department will continue to

 

 

 

provide advice on any product manufactured by Cobalt Digital Inc., beyond

 

 

 

the warranty period without charge, for the life of the product.

 

 

 

See Contact Cobalt Digital Inc. (p. 1-15)in Chapter 1, “Introduction“for

 

 

 

contact information.

 

 

3-40

9084 PRODUCT MANUAL

9084-OM (V4.0)

Image 64
Contents 9084 Cobalt Digital IncDisclaimer CopyrightTrademark Information Table of Contents Operating Instructions Introduction OverviewCard Software Versions and this Manual SupportDownloads link atManual Conventions E201Safety Summary Labeling Symbol DefinitionsFunctional Description Input/OutputsVideo ProcessorColor Corrector Color Corrector Video ProcessorFrame Sync Function AFD InserterComputer with NIC DashBoard Remote Control User Control InterfaceCard Edge Controls Controller CardOther cards installed in openGear frames such as the Cobalt Video Formats Supported by Rear I/O ModulesRaster Structure Frame Rate Technical Specifications CharacteristicTechnical Specifications Introduction Warranty and Service Information Cobalt Digital Inc. Limited WarrantyContact Cobalt Digital Inc PhoneFax Web General Information Technical SupportThis page intentionally blank Installation and Setup Installing the 9084 Into a Frame SlotInstalling the 9084 Into a Frame Slot Installation and Setup Installing a Rear I/O ModuleSetting Up 9084 Network Remote Control Rear I/O Module InstallationOperating Instructions Control and Display DescriptionsFunction Submenu/Parameter Submenu Overview Submenu a Submenu b Submenu z Individual ParametersCard Edge Controls, Indicators, and Display FunctionMenu Depth LEDs Card Edge Control Menu/Submenu StructureNone Card Edge Setup Abbreviated Diagram VidSubmenu Depth ClrCS p DashBoard User Interface Channel Black Adj Set Enable to OnCorrection Cobalt Remote Control Panel User Interfaces Control Panel Setup of Example Video Proc FunctionAccessing the 9084 Card via Remote Control Accessing the 9084 Card Using DashBoardAccessing the 9084 Card Using a Cobalt Remote Control Panel Checking Card Using Info Card Edge Controls Power Consumption and Temperature DisplaysChecking 9084 Card Information Software Version NumberDefault Line No. / Range Ancillary Data Line Number Locations and RangesFormat Line No. Limiting FormatFunction Submenu List and Descriptions Function Submenu ItemReset to Unity Video ProcLuma Gain Luma LiftColor Phase Color GainGang Luma and Color Gain Black Hard ClipApplies white hard clip limiting at specified percentage 50.0% to 109.1% null = 109.1%Card Edge Control Menu Applies white soft clip limiting at specified percentageOutput Mode Incoming AFDOutput Code Output LineOperating Instructions Black Adj. Green Red BlueGang Black Level Controls White Adj. Green Red BlueGang Gamma Controls Vertical Delay Control Framesync EnableHorizontal Delay Control Video Delay Display Loss of Input Signal SelectionMinimum Latency Frames Control Framesync Status DisplayReset Framesync Framesync LOS Freeze ColorCustom Color Hue Custom Color SaturationPreset Name field and Preset Save button Preset Load button and the Selected PresetPreset Save and Load Selected Preset drop-down listReset Current Preset Function Parameter/Setting Video ProcPreset Name Download PresetsColor and Video Correction Examples Using Feed To SwitcherOn-Set Monitor Color Correction Example Anchor Desk Set with Monitor10 Uncorrected Uncompensated Monitor Waveform To Switcher From Monitor Video Feed 12 Applying Correction to Example Monitor Waveform Signal Condition Observed On Waveform Monitor Correction Using Miscellaneous Color and Video Correction ExamplesLuma gain less than 100% level as shown below for VAR10.PNG VAR10A.PNG Troubleshooting Error and Failure Indicator OverviewCard Edge Status/Error Indicators and Display Status/Error Input Format Indicators IndicatorsCharacter Alphanumeric Display AlphanumericDashBoard Status/Error Indicators and Displays Indicator Icon or Display Error Description15 Selecting Specific Cards for Card Info Status Display Basic Troubleshooting Checks ChecksProcessing Error Troubleshooting Symptom Error/Condition Corrective ActionTroubleshooting Network/Remote Control Errors Case of ProblemsPage 2406 E. University Ave. Urbana, IL 9084-OM