Baldor EXB009A01 manual Section Software Setup, Configure Control Software

Page 28

Section 5

Software Setup

Configure Control Software

After the Resolver to Digital Interface board has been installed and the DIP switches are correctly set, the control software must be configured.

Series 18H and 22H Vector Controls

Note: When the Resolver to Digital Interface board is installed,

the encoder inputs to the control are automatically disabled (J1 pins 23 to 30).

The value of the Level 2, MOTOR DATA Block, ªResolver Speedº parameter (P2509) must be set to the correct speed value.

Procedure:

1.At the keypad, access the Level 2 Blocks.

2.Scroll to and access the Motor Data Block.

3.Access the Resolver Speed parameter. Change its' value to the Resolver Speed Type. Example: For a 2 pole Resolver, enter 1 (1 Speed). Example: For a 6 pole Resolver, enter 3 (3 Speed).

Series 19H and 20H DC SCR Controls

The value of the Level 2, MOTOR DATA Block, ªFeedback ypeºT parameter (P2507) and ªResolver Speedº parameter (P2509) must be set.

Procedure:

1.At the keypad, access the Level 2 Blocks.

2.Scroll to and access the Motor Data Block.

3.Access the Feedback Type parameter. Change its' value to RESOLVER.

4.Access the Resolver Speed parameter. Change its' value to the Resolver Speed Type. Example: For a 2 pole Resolver, enter 1 (1 Speed). Example: For a 6 pole Resolver, enter 3 (3 Speed).

Software 5-1

Image 28
Contents Installation and Operating Manual MN1313Table of Contents Hardware Setup Connections Introduction Section General InformationGroup 2 Board Name Limited Warranty Safety Notice General Information Section Expansion Board Description SpecificationsResolver to Digital interface Maximum Motor Speed / Resolver Speed Section Installation Board InstallationSingle Expansion Board Installation 15HP Size a and B ControlsSingle Expansion Board Installation Dual Expansion Board Installation Dual Expansion Board Installation 15HP Size C and Larger AC Controls Expansion Board Motor Control Board Dual Expansion Board Installation Dual Expansion Board Installation SCR DC Controls For 19H and 20H SCR DC ControlsSCR DC Controls Installation Section Hardware Setup Feedback Module Identification Main Control BoardFeedback Module Removal Procedure Connections Switch and Terminal Locations Switch Settings Resolver ConnectionsSetup Section Software Setup Configure Control SoftwareSeries 18H and 22H Vector Controls Series 19H and 20H DC SCR ControlsSoftware Box Fort Smith, AR 72902±2400 501 646±4711 Fax 501 648±5792  Baldor Electric Company MN1313 98 C&J2500