Baldor EXB009A01 manual Section Expansion Board Description, Specifications

Page 8

Section 2

Expansion Board Description

Introduction

Resolver to Digital Interface Expansion Board

Catalog No. EXB009A01

Group 1 Expansion Board

The Resolver to Digital Interface expansion board provides closed loop operation for the Baldor Series 18H, 19H, 20H and 22H controls. The Resolver to Digital Interface can also be used for PID control.

Note: When a Resolver to Digital Interface is used in a process control application, an encoder should be used to provide velocity feedback to the control.

Specifications

The Resolver to Digital interface is used with a motor mounted resolver. This provides the correct feedback signals for the Baldor Control. The control can then monitor and control shaft position. The Buffered Encoder Output (Retransmit) signals are still available from the control.

Resolver to Digital interface

Resolver Reference Supply

4 Volts, 25 mA maximum

 

(@ 10KHz)

DIgital Resolution

10, 12, 14, 16 bits (selectable)

Resolver Input Channels

± Sine, ± Cosine

Resolver Impedance

160 Ohms @ 10KHz minimum

Resolver Return Voltage

2 Volts minimum

Resolver Transformation Ratio

2:1 (0.5 TR)

Resolver Speeds

1:128 (selectable)

Connector

Screw Terminals

Description 2-1

Image 8
Contents Installation and Operating Manual MN1313Table of Contents Hardware Setup Connections Group 2 Board Name Section General InformationIntroduction Limited Warranty Safety Notice General Information Resolver to Digital interface SpecificationsSection Expansion Board Description Maximum Motor Speed / Resolver Speed Section Installation Board InstallationSingle Expansion Board Installation 15HP Size a and B ControlsSingle Expansion Board Installation Dual Expansion Board Installation Dual Expansion Board Installation 15HP Size C and Larger AC Controls Expansion Board Motor Control Board Dual Expansion Board Installation Dual Expansion Board Installation SCR DC Controls For 19H and 20H SCR DC ControlsSCR DC Controls Installation Section Hardware Setup Feedback Module Identification Main Control BoardFeedback Module Removal Procedure Connections Switch and Terminal Locations Switch Settings Resolver ConnectionsSetup Section Software Setup Configure Control SoftwareSeries 18H and 22H Vector Controls Series 19H and 20H DC SCR ControlsSoftware Box Fort Smith, AR 72902±2400 501 646±4711 Fax 501 648±5792  Baldor Electric Company MN1313 98 C&J2500