Baldor Resolver to Digital Expansion Board, EXB009A01 manual Dual Expansion Board Installation

Page 13

1-15HP Size A and B Controls (Continued)

Dual Expansion Board Installation

Procedure:

1.Be sure drive operation is terminated and secured.

2.Remove all power sources from the control.

3.Wait at least 5 minutes for internal capacitors to discharge.

4.Remove the four (4) Phillips head screws that secure the control cover.

5.Remove the control cover.

6.Remove the #6 screw at position MH1 (upper left on the main circuit board. See Figure 3-1.

7.Install the long standoffs provided in the installation hardware as shown in Figure 3-1. (Be sure the Male/Female standoff is at position MH1. The other three are Female/Female.)

8.Slide the Group 1 board male connector into the female connector of the control board. See Figure 3-3.

9.Securely mount the Group 1 expansion board to the standoffs installed in step 7 using the 4 short aluminum standoffs provided in the installation hardware. See Figure 3-3.

10.The mechanical installation of the Group 1 expansion board is now complete. Refer to the manual for the Group 1 board and configure the jumpers as desired. Also complete the wiring before you proceed to step 11.

11.Install the Group 2 board on top of the previously installed Group 1 board by plugging the female connector onto the male connector of the Group 1 board as shown in Figure 3-3.

12.Secure this Group 2 board to the Group 1 board using the #6 screws provided.

3-4 Installation

Image 13
Contents MN1313 Installation and Operating ManualTable of Contents Hardware Setup Connections Introduction Section General InformationGroup 2 Board Name Limited Warranty Safety Notice General Information Section Expansion Board Description SpecificationsResolver to Digital interface Maximum Motor Speed / Resolver Speed Board Installation Section Installation15HP Size a and B Controls Single Expansion Board InstallationSingle Expansion Board Installation Dual Expansion Board Installation Dual Expansion Board Installation 15HP Size C and Larger AC Controls Expansion Board Motor Control Board Dual Expansion Board Installation Dual Expansion Board Installation For 19H and 20H SCR DC Controls SCR DC ControlsSCR DC Controls Installation Feedback Module Identification Main Control Board Section Hardware SetupFeedback Module Removal Procedure Connections Switch and Terminal Locations Resolver Connections Switch SettingsSetup Configure Control Software Section Software SetupSeries 18H and 22H Vector Controls Series 19H and 20H DC SCR ControlsSoftware  Baldor Electric Company MN1313 98 C&J2500 Box Fort Smith, AR 72902±2400 501 646±4711 Fax 501 648±5792