MACRO-CPU Hardware Reference
Switch Configurations
SW1: MACRO Slave Node Configure
SW1 | # of Servo | MACRO | Station | Station | 1st Axis | 2nd Axis | PMAC2's I996 | PMAC2's I1000, |
Setting | Channels | Servo | Channel | Channel | Board | Board | Value ** | I1002 Value |
| & Nodes | Nodes | Nos. | Starting | Servo | Servo | (Turbo | (Turbo |
| Used | Specified |
| Addresses | IC | IC | PMAC2’S | PMAC2’s I70, |
|
|
|
|
|
|
| I6840, etc. | I71, etc.) |
0 | 4 | 0, 1, 4, 5 | 1, 2, 3, 4 | $C000, $C008, | None | $F8033 | $0033 | |
(default) |
|
|
| $C010, $C018* |
|
|
|
|
1 | 4 | 8, 9, 12, | 1, 2, 3, 4 | $C000, $C008, | None | $FB300 | $3300 | |
|
| 13 |
| $C010, $C018* |
|
|
|
|
2 | 2 | 0, 1 | 1, 2 | $C000, $C008* | None | $F8003 | $0003 | |
3 | 2 | 4, 5 | 3, 4 | $C010, $C018* | None | $F8030 | $0030 | |
4 | 2 | 8, 9 | 1, 2 | $C000, $C008* | None | $F8300 | $0300 | |
5 | 2 | 12, 13 | 3, 4 | $C010, $C018* | None | $FB000 | $3000 | |
6 | 6 | 0, 1, 4, 5, | 1, 2, 3, 4, | $C000, $C008, | $F8333 | $0333 | ||
|
| 8, 9 | 5, 6 | $C010, $C018, |
|
|
|
|
|
|
|
| $C020, $C028* |
|
|
|
|
7 | 8 | 0, 1, 4, 5, | 1, 2, 3, 4, | $C000, $C008, | $FB333 | $3333 | ||
|
| 8, 9, 12, | 5, 6, 7, 8 | $C010, $C018, |
|
|
|
|
|
| 13 |
| $C020, $C028, |
|
|
|
|
|
|
|
| $C030, $C038* |
|
|
|
|
8 | 2 | 0, 1 | 9, 10 | $C090, $C098 | None | $F8003 | $0003 | |
9 | 2 | 4, 5 | 9, 10 | $C090, $C098 | None | $F8030 | $0030 | |
10 | 2 | 8, 9 | 9, 10 | $C090, $C098 | None | $F8300 | $0300 | |
11 | 2 | 12. 13 | 9, 10 | $C090, $C098 | None | $FB000 | $3000 | |
12 | 6 | 0, 1, 4, 5, | 1, 2, 3, 4, | $C000, $C008. | $FB333 | $0333 | ||
|
| 8, 9 | 9, 10 | $C010, $C018,* |
|
|
|
|
|
|
|
| $C090, $C098 |
|
|
|
|
13 | 0 | None | None | None | None | None | $F8000 | $0000 |
| (I/O only) |
|
|
|
|
|
|
|
14 | (Reserved | For | Future | Use) |
|
|
|
|
15 | 0 | 11 | - | - | - | - | $F8800 | - |
*** |
|
|
|
|
|
|
|
|
* These addresses are for stack axis boards. Add $40 to these addresses for backplane axis boards.
** Other bits of this
*** A setting of 15 forces the station to use its factory default
SW2: MACRO Master Number Select
0:Commanded from Master IC # 0
1:Commanded from Master IC # 1
…
F: Commanded from Master IC # F (15)
3U | 15 |