Ultimate Technology 500 POS manual Copying Keyboard Setup Data Cloning

Page 64

COPYING KEYBOARD SETUP DATA (CLONING)

Once a keyboard has been programmed, the parameters can be copied from the source keyboard to other keyboards. This feature saves time and reduces errors when programming more than one keyboard. It is also useful for remote keyboard setup and when making changes in key codes. Downloading of keyboard parameters can be done using one of two methods. The first method is initiated by using the GETSET command (Table 5) issued from the host. This sends all setup data such as baud rate, key codes and macros to the main port of the keyboard in command format.

The second method is performed in the local programming mode with the source and target keyboards connected together. This method can only be used when the main ports are configured as RS232 type ports. To use this method proceed as follows.

1.Connect a cable, UTC Part No. CAB20135 or equivalent, and external 5-volt power adapter, UTC Part No. CAB20136 or equivalent to the source and target Series 500 Keyboards as shown below. Schematics showing the pin and signal data for the cable and power adapter are provided in Appendix B.

SOURCE UNIT

DESTINATION UNIT

SERIES 500 Main

CAB20135

Main

SERIES 500

RS232

Port

RS232

Port

Aux

RS232

Port

CAB20136

+5VDC Supply

Figure 5. Keyboard downloading connection diagram

56

Image 64
Contents Programming & USER’S Guide To Program a Primary Key Series 500 Quick Reference GuideTable of Contents Maintenance List of Tables Series 500 POS Keyboard Special Note ScopeUltimate Technology Corporation Series 500 POS Keyboard Product Information FeaturesModel Description Optional Pedestal Mount Service and Warranty SpecificationsInstallation Unpacking and InspectionExternal Connections Drawer Jumper Connections Printer FiredCAB20138 Typical keyboard external connections Keyboard external connectors rear view Controls and Indicators OperationPage Page Programming Local Mode Programming Function Codes and Default SettingsProgramming Keyboard Operating Parameters MSR Local Mode Programming Function Codes and Default Settings Local Mode Programming Function Codes and Default Settings Local Mode Programming Function Codes and Default Settings Local Mode Programming Function Codes and Default Settings Local Mode Programming Instructions Local Mode Programming Instructions LED 2 turns on LED Turns on Move switch out of the AUX position 20 or 21 or 23 or 25 or O r D 2 f l a s h e s Applicable Function Code 45, 46, 47 or Indicator LED Code Mode LED 2 flashes Select override secure mode of operation per list below Default Keyboard Code Series Keyboard Description Numeric Keypad no BreakPage Page Programming in Remote Mode Page Command A0krcCxDx.......CR Acknowledgement NoneCommand A1aCxDx.......CR Code HEXMNEMONIC/DESCRIPTION COMMAND/ACKNOWLEDGEMENT Code HEX Snddly Command A2CxDxCRCommand A3PbbbbbwsphCR MNEMONIC/DESCRIPTION COMMAND/ACKNOWLEDGEMENT Code HEXCommand A4xxxx-xxxxCR Command A5xCxDxCR Command A6xCRCommand A7hhhmCR ClickedRawed Nvbdclr Command A9CLRCRSecure Command B0LxCR Command AFxxxx-xxxxCRLight Command B1pdCR Command B2p...........CR MNEMONIC/DESCRIPTION COMMAND/ACKNOWLEDGEMENT Code HEX SendpCommand B3CR Command B4CR Reset Command B5RSTCRKssnd Command B6CR Ksstatus Command B7CRCommand B9cCR Command B8xCRCarded Command BBpCR Command BApCRCdcont Command BCpCR Command BDpxCRAcknowledgement PorteCommand Becr Getset Command BfcrBEnnnnnvvvvkkkkx-xCR BF...............CRRemote Description Programming Command Programming KEY MAKE/BREAK CodesWhere A0 Examples of Remote Programming for KEY MAKE/BREAK CodeExample Parameters same as shown for example Copying Keyboard Setup Data Cloning Keyboard downloading connection diagramOperators and Programmers Magnetic Cards System LOGMaintenance PrecautionsCleaning KEY Legend Change 5/8-INCH Full Travel KeyboardsBattery Replacement KEY Legend Change Flat Tactile MembranePage Appendix a Series 500 POS Standard Keyboard Layouts Page Compact 5/8-Inch Qwerty Layout Appendix B Keyboard CABLE/CONNECTOR Data Back Connector Pinouts Adapter Cable PinoutsAppendix C Ascii Character SET DLEScan Code KEY Number Decimal Hexadecimal2B/AB Scan Code KEY Number 4F/CF 3B/BB E1 14 77 E1 62/F0 9D C5 F0 14 F0 One Year Limited Service Warranty Terms & Conditions Ultimate Technology CorporationRawson Road VICTOR, NEW York