Ultimate Technology 500 POS manual 20 or

Page 31

Table 3. Local Mode Programming Instructions - Continued

Note: *Default Settings

Function Code(s)

Operation

Normal Indication

Remarks

 

 

 

 

4.

Program the next function code or exit programming mode by entering 99

 

 

on Series 500 Keyboard numeric keypad or by swiping the

 

 

Programmer's card. If using the optional 3-pos ition keyswitch, move

 

 

switch out of the AUX position.

 

 

 

 

19

1.

While in programming mode, at the Series 500 Keyboard numeric keypad, enter

MSR Send

 

applicable Function Code 19.

 

 

 

 

LED (2) turns on.

 

 

2.

At the Series 500 Keyboard numeric keypad, enter the applicable number (0 or 1) per

 

 

list below to select MSR data from one or both good tracks.

 

 

 

0 = send any good track*

 

 

 

 

1 = send only if all enabled tracks good

 

3.

Program the next function code or exit programming mode by entering 99 on Series

 

 

500 Keyboard numeric keypad or by swiping the Programmer's card. If using the

 

 

optional 3-position keyswitch, move switch out of the AUX position.

 

 

 

20 or 30

1.

While in programming mode, at the Series 500 keyboard numeric keypad, enter

Comm (RS232)

 

Function Code 20 (Port 0) or 30 (Port 1).

 

Main Port 0 (20)

 

 

 

 

AUX Port 1 (30)

 

 

LED (2) turns on.

 

Baud Rate

 

 

 

 

2.At Series 500 Keyboard numeric keypad, enter the applicable number (1 through 9) to select baud rate per list below.

1 = 300

6

= 9600*

2

= 600

7 = 19200

3

= 1200

8

= 38400

4

= 2400

9

= 57600

5

= 4800

 

 

LED (2) turns off.

3.Program the next function code or exit programming mode by entering 99 on Series 500 Keyboard numeric keypad or by swiping the Programmer's card. If using the optional 3-position keyswitch, move switch out of the AUX position.

23

Image 31
Contents Programming & USER’S Guide Series 500 Quick Reference Guide To Program a Primary KeyTable of Contents Maintenance List of Tables Series 500 POS Keyboard Special Note ScopeUltimate Technology Corporation Series 500 POS Keyboard Product Information FeaturesModel Description Optional Pedestal Mount Specifications Service and WarrantyUnpacking and Inspection InstallationDrawer Jumper Connections Printer Fired External ConnectionsCAB20138 Typical keyboard external connections Keyboard external connectors rear view Operation Controls and IndicatorsPage Page Programming Local Mode Programming Function Codes and Default SettingsProgramming Keyboard Operating Parameters MSR Local Mode Programming Function Codes and Default Settings Local Mode Programming Function Codes and Default Settings Local Mode Programming Function Codes and Default Settings Local Mode Programming Function Codes and Default Settings Local Mode Programming Instructions Local Mode Programming Instructions LED 2 turns on LED Turns on Move switch out of the AUX position 20 or 21 or 23 or 25 or O r D 2 f l a s h e s Applicable Function Code 45, 46, 47 or Indicator LED Code Mode LED 2 flashes Select override secure mode of operation per list below Default Keyboard Code Break Series Keyboard Description Numeric Keypad noPage Page Programming in Remote Mode Page Acknowledgement None Command A0krcCxDx.......CRCode HEX Command A1aCxDx.......CRCommand A2CxDxCR MNEMONIC/DESCRIPTION COMMAND/ACKNOWLEDGEMENT Code HEX SnddlyCommand A3PbbbbbwsphCR MNEMONIC/DESCRIPTION COMMAND/ACKNOWLEDGEMENT Code HEXCommand A4xxxx-xxxxCR Clicked Command A5xCxDxCRCommand A6xCR Command A7hhhmCRRawed Nvbdclr Command A9CLRCRSecure Command B0LxCR Command AFxxxx-xxxxCRLight Command B1pdCR Command B2p...........CR MNEMONIC/DESCRIPTION COMMAND/ACKNOWLEDGEMENT Code HEX SendpCommand B3CR Ksstatus Command B7CR Command B4CRReset Command B5RSTCR Kssnd Command B6CRCommand B9cCR Command B8xCRCarded Command BBpCR Command BApCRCdcont Porte Command BCpCRCommand BDpxCR AcknowledgementBF...............CR Command BecrGetset Command Bfcr BEnnnnnvvvvkkkkx-xCRProgramming KEY MAKE/BREAK Codes Remote Description Programming CommandExamples of Remote Programming for KEY MAKE/BREAK Code Where A0Example Parameters same as shown for example Keyboard downloading connection diagram Copying Keyboard Setup Data CloningSystem LOG Operators and Programmers Magnetic CardsKEY Legend Change 5/8-INCH Full Travel Keyboards MaintenancePrecautions CleaningKEY Legend Change Flat Tactile Membrane Battery ReplacementPage Appendix a Series 500 POS Standard Keyboard Layouts Page Compact 5/8-Inch Qwerty Layout Back Connector Pinouts Adapter Cable Pinouts Appendix B Keyboard CABLE/CONNECTOR DataDLE Appendix C Ascii Character SETDecimal Hexadecimal Scan Code KEY Number2B/AB Scan Code KEY Number 4F/CF 3B/BB E1 14 77 E1 62/F0 9D C5 F0 14 F0 VICTOR, NEW York One Year Limited Service Warranty Terms & ConditionsUltimate Technology Corporation Rawson Road