Trango Broadband TrangoLink-10 CLI Command freq ch pol, Rfrxth ism, Power setism max min dBm

Page 18

Configuration

Basic Diagnostics

Parameter

Description

Associated Page and Notes

 

 

set mir [<downstream kbps, 100..10000>

 

 

<upstream kbps, 100..10000>]

 

 

 

Downstream

Current throughput from Master Unit to

Informational Parameter

Throughput

Remote Unit.

 

Upstream

Current throughput from Remote Unit to

Informational Parameter

Throughput

Master Unit.

 

Active Channel

Current RF channel and polarization (v)ertical or

Configuration page

 

(h)orizontal.

CLI Command: freq <ch> <pol>

RF RX Threshold

Specifies the receiver sensitivity of the radio.

Advanced page

 

This user-changeable parameter is a powerful

CLI Command:

 

tool that is useful for mitigating the effects of

rfrxth <ism > <-90-85-80-75-70-65>

 

interference. The radio will not process any

 

 

signals receieved that are weaker than the RF

 

 

RX threshold.

 

RF TX Power

Transmit power of the radio (not including

Advanced page

 

antenna gain)

CLI Command:

 

 

power <setism> <max min dBm>

Channel Table

Assigns channel numbers to actual

Advanced page

 

frequencies of operation. The default channels

CLI Command:

 

1 – 6 are assigned to ISM band. Note: All

freq writechannel [<ch#> <freq>] ...

 

channels may be re-assigned as desired by the

 

 

user. Default settings allow optimum use of

 

 

the available spectrum. The frequencies

 

 

assigned on the Master Unit must match those

 

 

on the Remote Unit.

 

Broadcast Packet

This switch (0) enables/disables the blocking of

Configuration page

Filter

Ethernet control packets, except ICMP and ARP,

CLI Command:

 

to reduce the amount of unnecessary overhead

sw 0 [<on off>]

 

introduced to the wireless link

 

Remarks

User definable radio information (i.e. customer

Informational Parameter

 

name, address of installation, and so on).

CLI Command:

 

Maximum 28 characters can be stored.

remarks <remarks>

Eth In

Eth In: Counter for Ethernet packets that

Informational Parameter

 

entered via the Ethernet port of the radio.

 

Eth Out

Counter for Ethernet packets that exited via

Informational Parameter

 

the Ethernet port of the radio.

 

RF In

Counter for Ethernet packets that entered

Informational Parameter

 

over-the-air into the radio.

 

RF Out

Counter for Ethernet packets that exited over-

Informational Parameter

 

the-air out of the radio.

 

Trango Broadband Wireless — TrangoLINK-10 User Manual Rev. E 3.0

page 14

Image 18
Contents TrangoLINK-10 Point to Point Wireless Ethernet Bridge Table of Contents Table of Figures Table of TablesWarranty Information PrefaceFCC Information Contents OverviewOperational Overview Ethernet and Serial PortsConnections and Power Getting StartedBasic Configuration Concepts and Tools Opmode ConceptSysinfo Command Line Interface TroubleshootingTelnet ip address of radio Type resetpassword Serial PortConfiguration This section you willSettings Remote Unit Configuration Screen Basic Diagnostics Master Unit’s System Information CLI Command tftpd on off Set defaultopmode on offIpconfig ip subnet gateway CLI Command set remoteid RU’s MACRfrxth ism CLI Command freq ch polPower setism max min dBm Freq writechannel ch# freqSet defaultopmode onoff Remote Unit System InformationTftpd on off Sw 0 on off Sw 1 on offSw 2 on off Deployment & Installation Site SelectionSite survey Installation Channel PlanningMounting Hardware Mounting Hardware Assembly Cabling and Weather Considerations Standard Mounting Alternative MountingRU Installation and Antenna Alignment RU Antenna Alignment ProcedureLink Test Management RU ManagementObjects for Monitoring and Control RU Bandwidth MonitoringSnmp Setup Command Description RemarkSame as updateflash OFF Appendix B Specifications