Trango Broadband TrangoLink-10 user manual Snmp Setup

Page 29

Management

SNMP

SNMP Setup

Trango Broadband provides only the MIB portion of the SNMP Management system. The radios act as individual agents, and it is up the user to provide SNMP Manager software from a third party vendor. Below is an example of the setup process for SNMPc from Castle Rock™.

1.Unzip trangopkg.zip file to a local temporary directory.

2.Go to your local temporary directory, you will see 4 files shown below.

a.trango_P5830Sap_1p0.mib – M5800S MU MIB file

b.trango.ico – P5830S MU icon

c.autoico.txt – instruction file (Selects Trango icon automatically during initial set-up.)

3.Copy trango_P5830Smu_1p0.mib file to C:\Program Files\SNMPc Network Manager\mibfiles

4.Copy autoico.txt file to C:\Program Files\SNMPc Network Manager\mibfiles

5.Copy trango.ico file to C:\Program Files\SNMPc Network Manager\bitmaps

6.The MIB needs to be compiled into the SNMPc database

By default, the Read Community is set to “public,” and Write Community is set to “private” in the MU. The Trap Community is “SNMP_trap.” The manager needs to have the same settings in order to communicate with the MU successfully.

Note: The Trap Community cannot be set via HTTP or CLI. To send traps from the MU, set the following:

trap destination IP (Trango MIB object trapconfig–trapconfigInfo)

trap community string (Trango MIB object trapconfig–MutrpTable-MutrpEntry)

enable each trap (Trango MIB object traponfig–mutrpTable-MutrpEntry)

For all set operations, set object SaveAndActivate at musystem-musystemInfoto write the information to FLASH.

Trango Broadband Wireless — TrangoLINK-10 User Manual Rev. E 3.0

page 25

Image 29
Contents TrangoLINK-10 Point to Point Wireless Ethernet Bridge Table of Contents Table of Tables Table of FiguresFCC Information Warranty InformationPreface Overview ContentsEthernet and Serial Ports Operational OverviewGetting Started Connections and PowerOpmode Concept Basic Configuration Concepts and ToolsSysinfo Telnet ip address of radio Command Line InterfaceTroubleshooting Serial Port Type resetpasswordThis section you will ConfigurationSettings Remote Unit Configuration Screen Basic Diagnostics Master Unit’s System Information Ipconfig ip subnet gateway Set defaultopmode on offCLI Command tftpd on off CLI Command set remoteid RU’s MACPower setism max min dBm CLI Command freq ch polRfrxth ism Freq writechannel ch# freqTftpd on off Set defaultopmode onoffRemote Unit System Information Sw 2 on off Sw 0 on offSw 1 on off Site survey Deployment & InstallationSite Selection Mounting Hardware InstallationChannel Planning Mounting Hardware Assembly Standard Mounting Alternative Mounting Cabling and Weather ConsiderationsRU Antenna Alignment Procedure RU Installation and Antenna AlignmentLink Test RU Management ManagementRU Bandwidth Monitoring Objects for Monitoring and ControlSnmp Setup Remark Command DescriptionSame as updateflash OFF Appendix B Specifications