Trane BACnet Option Module Reset Control Timeout, Diagnosis Trigger, Control Profile, Protocol

Page 47

Parameters

8-06 Reset Control Timeout

Option:

 

Function:

 

 

This parameter is active only when the choice Hold set-up[0] has been

 

 

selected in par.8-05End-of-Timeout Function.

 

 

 

 

 

 

 

[0] *

Do not reset

Retains the set-up specified in par.8-04Control Timeout Function, [Select

 

 

 

 

 

 

 

set-up 1-4] following a control timeout.

 

 

 

 

 

 

 

[1]

Do reset

Returns the adjustable frequency drive to the original set-up following a

 

 

control word timeout. When the value is set to Do reset [1], the adjustable

 

 

frequency drive performs the reset and then immediately reverts to the

 

 

Do not reset [0] setting.

 

 

 

 

 

 

 

8-07

Diagnosis Trigger

Option:

Function:

 

 

 

This parameter has no function for LonWorks.

 

 

[0] *

Disable

[1]Trigger on alarms

[2]Trigger alarm/warn.

8-10 Control Profile

Option:Function:

Select the interpretation of the control and status words corresponding to the installed serial communication bus. Only the selections valid for the serial communication bus installed in slot A will be visible in the keypad display.

[0]* FC profile

[1]PROFIdrive profile

[5]ODVA

[7]CANopen DSP 402

8-30 Protocol

Option:Function:

[0] *

FC

[1]FC MC

Protocol selection for the integrated FC (standard) Port (RS485) on the control card.

Parameter group 8-7* is only visible when Adjustable Frequency Drive Option [9] is chosen.

Communication according to the FC protocol as described in the TR200 Design Guide, RS 485 Installation and Set-up .

Same as FC [0] but to be used when downloading SW to the adjustable frequency drive or uploading dll file (covering information regarding pa- rameters available in the adjustable frequency drive and their inter- dependencies) to Trane Drive Utility, TDU.

[2]

Modbus RTU

Communication according to the Modbus RTU protocol as described in

 

 

the TR200 Design Guide, RS 485 Installation and Set-up .

 

 

 

[3]

Metasys N2

Communication protocol. The N2 software protocol is designed to be

 

 

general in nature in order to accommodate the unique properties each

 

 

 

6-4

TR200 BACnet

Image 47
Contents TR200 Introduction LED Status Copyright, limitation of liability and revision rights SafetySafety Safety Regulations Safety High Voltage WarningSafety Note Installation at high altitudes Min. Waiting Time Minutes VoltageSafety Safety Precautions Protection Mode Electrical ratings Safety Before Commencing Repair WorkInstallation requirements Technical Overview IntroductionAbout this Manual Transport mechanism Physical characteristicsIntroduction Background informationAvailable Literature for TR200 Introduction AssumptionsBackground Knowledge LED MAV MOC MRV Introduction AbbreviationsInstallation of the Option How to InstallCable lengths and number of nodes How to InstallCabling InstructionsHow to Install Maximum Cable Lengths How to Install Network TerminationConnecting the Bus Line Connection of the Cable Shield How to Install Cable RoutingEMC Precautions How to Install Ground Connection Initialization Parameter How to Configure the SystemInitialization Procedure Bibbs How to Configure the SystemControl Word Timeout Function Name Par. number Value How to Configure the System Closed-loop How to Control the Adjustable Frequency DriveReference Handling Open-loopAnalog Input and Output Objects How to Control the Adjustable Frequency DriveRameter Notifi Timeout Scription Rameter Bus Change- Non-vola Alarm Triggers Object Name Able DeCation Timeout ObjectNon-vola Alarm Triggers Bus Able De BO30 Reserved Output Object Name Able De Change Non-vola AlarmWrite Timeout Scription Triggers Bus Timeout How to Control the Adjustable Frequency DriveChange Non-vola Alarm Object Name Able De BV80 Broken Belt BV121 10V low BV156 Reserved, P Drive Par Write Change- Non-vola Alarm Object Name Able DeMulti-state Input and Output Objects Write Scription Real Time Clock VariableObject Read Change- Non-vola Adjustable Frequency Drive Feedback to Network Value Class Output ValueOutput Value Stage Multi Stage File value Event notifi- cation class Object / Property Support Matrix Device BinaryHow to Control the Adjustable Frequency Drive Parameter List Title Default value Range Conver Data Sion index TypeParameters Control Site Control Timeout TimeParameters Comm. and OptionsEnd-of-Timeout Function Control Timeout FunctionProtocol Reset Control TimeoutDiagnosis Trigger Control ProfileParity / Stop Bits ParametersAddress Baud RateCoasting Select Minimum Response DelayMax Response Delay Max Inter-Char DelaySet-up Select Start SelectReverse Select 72 MS/TP Max Masters Preset Reference SelectInitialization Password BACnet Device InstanceGeneral TroubleshootingAlarm and Warning Messages AlarmsBit Alarm Word Hex Par.16-90 Alarm Word Troubleshooting Alarm WordsAlarm word, par.16-90 Alarm Word Alarm word 2, par.16-91 Alarm wordBit TroubleshootingBit Hex Par.16-92 Warning Word LED 2 Module Status Phases Status Bi-color LEDLED 1 Net Status MG12L122 *MG12L122