Trane Essential Fault Codes and Troubleshooting for Systems

Page 53

Troubleshooting

Alarm Words

Alarm word, par.16-90 Alarm Word

 

Bit

Alarm Word

 

 

 

(Hex)

(par.16-90 Alarm Word)

 

 

 

00000001

Brake check

 

 

 

 

 

00000002

Power card overtemperature

 

 

 

00000004

Ground fault

 

 

 

00000008

Ctrl. card overtemperature

 

 

 

00000010

Control word timeout

 

 

 

00000020

Overcurrent

 

 

 

00000040

Torque limit

 

 

 

00000080

Motor thermistor overtemp.

 

 

 

00000100

Motor ETR overtemperature

 

 

 

00000200

Inverter overloaded

 

 

 

00000400

DC link undervoltage

 

 

 

00000800

DC link overvoltage

 

 

 

00001000

Short circuit

 

 

 

00002000

Soft-charge fault

 

 

 

00004000

Line phase loss

 

 

 

00008000

AMA not OK

 

 

 

00010000

Live zero error

 

 

 

00020000

Internal fault

 

 

 

00040000

Brake overload

 

 

 

00080000

Motor phase U is missing

 

 

 

00100000

Motor phase V is missing

 

 

 

00200000

Motor phase W is missing

 

 

 

00400000

Serial communication bus

 

 

 

fault

 

 

 

 

 

 

 

00800000

24 V supply fault

 

 

 

01000000

Line failure

 

 

 

02000000

1.8 V supply fault

 

 

 

04000000

Brake resistor short circuit

 

 

 

08000000

Brake chopper fault

 

 

 

10000000

Option change

 

 

 

20000000

Drive initialized

 

 

 

40000000

Safe Stop

 

 

 

80000000

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm word 2, par.16-91 Alarm word 2

 

Bit

Alarm Word 2

 

 

 

(Hex)

(par.16-91 Alarm word 2)

 

 

 

 

 

 

 

 

 

 

00000001

Service Trip, read / Write

 

 

 

00000002

Reserved

 

 

 

00000004

Service Trip, Typecode /

 

 

 

Spare part

 

 

 

 

 

 

 

00000008

Reserved

 

 

 

00000010

Reserved

 

 

 

00000020

No Flow

 

 

 

00000040

Dry Pump

 

 

 

00000080

End of Curve

 

 

 

00000100

Broken Belt

 

 

 

00000200

Not used

 

 

 

00000400

Not used

 

 

 

00000800

Reserved

 

 

 

00001000

Reserved

 

 

 

00002000

Reserved

 

 

 

00004000

Reserved

 

 

 

00008000

Reserved

 

 

 

00010000

Reserved

 

 

 

00020000

Not used

 

 

 

00040000

Fans error

 

 

 

00080000

ECB error

 

 

 

00100000

Reserved

 

 

 

00200000

Reserved

 

 

 

00400000

Reserved

 

 

 

00800000

Reserved

 

 

 

01000000

Reserved

 

 

 

02000000

Reserved

 

 

 

04000000

Reserved

 

 

 

08000000

Reserved

 

 

 

10000000

Reserved

 

 

 

20000000

Reserved

 

 

 

40000000

Reserved

 

 

 

80000000

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-2

TR200 BACnet

Image 53
Contents TR200 Introduction LED Status Copyright, limitation of liability and revision rights SafetySafety Safety Regulations Safety High Voltage WarningSafety Note Installation at high altitudes Min. Waiting Time Minutes VoltageSafety Safety Precautions Protection Mode Electrical ratings Safety Before Commencing Repair WorkInstallation requirements Technical Overview IntroductionAbout this Manual Introduction Physical characteristicsBackground information Transport mechanismAvailable Literature for TR200 Introduction AssumptionsBackground Knowledge LED MAV MOC MRV Introduction AbbreviationsInstallation of the Option How to InstallCabling How to InstallInstructions Cable lengths and number of nodesHow to Install Maximum Cable Lengths How to Install Network TerminationConnecting the Bus Line Connection of the Cable Shield How to Install Cable RoutingEMC Precautions How to Install Ground Connection Initialization Parameter How to Configure the SystemInitialization Procedure Bibbs How to Configure the SystemControl Word Timeout Function Name Par. number Value How to Configure the System Reference Handling How to Control the Adjustable Frequency DriveOpen-loop Closed-loopAnalog Input and Output Objects How to Control the Adjustable Frequency DriveRameter Notifi Timeout Scription Rameter Cation Timeout Change- Non-vola Alarm Triggers Object Name Able DeObject BusNon-vola Alarm Triggers Bus Able De BO30 Reserved Output Object Name Able De Change Non-vola AlarmWrite Timeout Scription Triggers Bus Timeout How to Control the Adjustable Frequency DriveChange Non-vola Alarm Object Name Able De BV80 Broken Belt BV121 10V low BV156 Reserved, P Drive Par Write Change- Non-vola Alarm Object Name Able DeMulti-state Input and Output Objects Write Scription Real Time Clock VariableObject Read Change- Non-vola Adjustable Frequency Drive Feedback to Network Value Class Output ValueOutput Value Stage Multi Stage File value Event notifi- cation class Object / Property Support Matrix Device BinaryHow to Control the Adjustable Frequency Drive Parameter List Title Default value Range Conver Data Sion index TypeParameters Parameters Control Timeout TimeComm. and Options Control SiteEnd-of-Timeout Function Control Timeout FunctionDiagnosis Trigger Reset Control TimeoutControl Profile ProtocolAddress ParametersBaud Rate Parity / Stop BitsMax Response Delay Minimum Response DelayMax Inter-Char Delay Coasting SelectSet-up Select Start SelectReverse Select Initialization Password Preset Reference SelectBACnet Device Instance 72 MS/TP Max MastersAlarm and Warning Messages TroubleshootingAlarms GeneralAlarm word, par.16-90 Alarm Word Troubleshooting Alarm WordsAlarm word 2, par.16-91 Alarm word Bit Alarm Word Hex Par.16-90 Alarm WordBit TroubleshootingBit Hex Par.16-92 Warning Word LED 2 Module Status Phases Status Bi-color LEDLED 1 Net Status MG12L122 *MG12L122