Trane TR200, BACnet Option Module Troubleshooting, Bit Hex Par.16-92 Warning Word

Page 54

Troubleshooting

Warning Words

Warning word , par.16-92 Warning Word

 

Bit

Warning Word

 

 

 

(Hex)

(par.16-92 Warning Word)

 

 

 

00000001

Brake check

 

 

 

 

 

00000002

Power card overtemperature

 

 

 

00000004

Ground fault

 

 

 

00000008

Ctrl. card overtemperature

 

 

 

00000010

Control word timeout

 

 

 

00000020

Overcurrent

 

 

 

00000040

Torque limit

 

 

 

00000080

Motor thermistor overtemp.

 

 

 

00000100

Motor ETR overtemperature

 

 

 

00000200

Inverter overloaded

 

 

 

00000400

DC link undervoltage

 

 

 

00000800

DC link overvoltage

 

 

 

00001000

DC link voltage low

 

 

 

00002000

DC link voltage high

 

 

 

00004000

Line phase loss

 

 

 

00008000

No motor

 

 

 

00010000

Live zero error

 

 

 

00020000

10 V low

 

 

 

00040000

Brake resistor power limit

 

 

 

00080000

Brake resistor short circuit

 

 

 

00100000

Brake chopper fault

 

 

 

00200000

Speed limit

 

 

 

00400000

Serial Communication Bus

 

 

 

comm. fault

 

 

 

 

 

 

 

00800000

24 V supply fault

 

 

 

01000000

Line failure

 

 

 

02000000

Current limit

 

 

 

04000000

Low temperature

 

 

 

08000000

Voltage limit

 

 

 

10000000

Encoder loss

 

 

 

20000000

Output frequency limit

 

 

 

40000000

Not used

 

 

 

80000000

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning word 2, par.16-93 Warning word 2

 

Bit

Warning Word 2

 

 

 

(par.16-93Warning word

 

 

 

(Hex)

 

 

 

2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00000001

Start Delayed

 

 

 

00000002

Stop Delayed

 

 

 

00000004

Clock Failure

 

 

 

00000008

Reserved

 

 

 

00000010

Reserved

 

 

 

00000020

No Flow

 

 

 

00000040

Dry Pump

 

 

 

00000080

End of Curve

 

 

 

00000100

Broken Belt

 

 

 

00000200

Not used

 

 

 

00000400

Reserved

 

 

 

00000800

Reserved

 

 

 

00001000

Reserved

 

 

 

00002000

Reserved

 

 

 

00004000

Reserved

 

 

 

00008000

Reserved

 

 

 

00010000

Reserved

 

 

 

00020000

Not used

 

 

 

00040000

Fans warning

 

 

 

00080000

ECB warning

 

 

 

00100000

Reserved

 

 

 

00200000

Reserved

 

 

 

00400000

Reserved

 

 

 

00800000

Reserved

 

 

 

01000000

Reserved

 

 

 

02000000

Reserved

 

 

 

04000000

Reserved

 

 

 

08000000

Reserved

 

 

 

10000000

Reserved

 

 

 

20000000

Reserved

 

 

 

40000000

Reserved

 

 

 

80000000

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TR200 BACnet

7-3

Image 54
Contents TR200 Introduction LED Status Safety Copyright, limitation of liability and revision rightsSafety Safety High Voltage Warning Safety NoteSafety Regulations Installation at high altitudes Voltage Min. Waiting Time MinutesSafety Safety Precautions Protection Mode Safety Before Commencing Repair Work Installation requirementsElectrical ratings Introduction About this ManualTechnical Overview Background information Physical characteristicsIntroduction Transport mechanismIntroduction Assumptions Background KnowledgeAvailable Literature for TR200 Introduction Abbreviations LED MAV MOC MRVHow to Install Installation of the OptionInstructions How to InstallCabling Cable lengths and number of nodesHow to Install How to Install Network Termination Connecting the Bus LineMaximum Cable Lengths How to Install Cable Routing EMC PrecautionsConnection of the Cable Shield How to Install Ground Connection How to Configure the System Initialization ProcedureInitialization Parameter How to Configure the System Control Word Timeout FunctionBibbs Name Par. number Value How to Configure the System Open-loop How to Control the Adjustable Frequency DriveReference Handling Closed-loopHow to Control the Adjustable Frequency Drive Analog Input and Output ObjectsRameter Notifi Timeout Scription Rameter Object Change- Non-vola Alarm Triggers Object Name Able DeCation Timeout BusNon-vola Alarm Triggers Bus Able De BO30 Reserved Output Change Non-vola Alarm Write Timeout ScriptionObject Name Able De How to Control the Adjustable Frequency Drive Change Non-vola Alarm Object Name Able DeTriggers Bus Timeout BV80 Broken Belt BV121 10V low BV156 Reserved, P Change- Non-vola Alarm Object Name Able De Multi-state Input and Output ObjectsDrive Par Write Real Time Clock Variable Object Read Change- Non-volaWrite Scription Adjustable Frequency Drive Feedback to Network Output Value Output Value StageValue Class Object / Property Support Matrix Device Binary Multi Stage File value Event notifi- cation classHow to Control the Adjustable Frequency Drive Title Default value Range Conver Data Sion index Type ParametersParameter List Comm. and Options Control Timeout TimeParameters Control SiteControl Timeout Function End-of-Timeout FunctionControl Profile Reset Control TimeoutDiagnosis Trigger ProtocolBaud Rate ParametersAddress Parity / Stop BitsMax Inter-Char Delay Minimum Response DelayMax Response Delay Coasting SelectStart Select Reverse SelectSet-up Select BACnet Device Instance Preset Reference SelectInitialization Password 72 MS/TP Max MastersAlarms TroubleshootingAlarm and Warning Messages GeneralAlarm word 2, par.16-91 Alarm word Troubleshooting Alarm WordsAlarm word, par.16-90 Alarm Word Bit Alarm Word Hex Par.16-90 Alarm WordTroubleshooting Bit Hex Par.16-92 Warning WordBit Phases Status Bi-color LED LED 1 Net StatusLED 2 Module Status MG12L122 *MG12L122
Related manuals
Manual 86 pages 30.73 Kb