1vv0300715 Rev. 1 - 19/09/06
3 Hardware Commands
3.1 Turning ON the GE863-QUAD/PY
To turn on the
The maximum current that can be drained from the ON# pad is 0,1 mA. A simple circuit to do it is:
R1
Power ON impulse
ON#
Q1
R2
GND
NOTE: don't use any pull up resistor on the ON# line, it is internally pulled up. Using pull up resistor may bring to latch up problems on the
NOTE: In this document all the lines that are inverted, hence have active low signals are labeled with a name that ends with a "#" or with a bar over the name.
NOTE: The
For example:
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Right reserved | page 11 of 79 |